PubMed HealthSearch

Biomedical subjects

J W Keyes

Publications and source records attributed to J W Keyes.

At least 19 recordsLinked to original sources

Sensitivity, resolution and image quality with a multi-head SPECT camera.

This investigation sought to determine which collimation factors were most important in providing superior image quality with a three-headed SPECT device. The relationship between sensitivity, resolution and SPECT image quality was studied. Two different sets of parallel-hole collimators were used. The ultrahigh-resolution collimators have higher spatial resolution (8.9 versus 11.0 mm), but only 55% of the sensitivity of the high-resolution collimators. A phantom with hot rods was imaged with both collimator sets. Observers compared images with the ultrahigh-resolution collimators to images of varying counts with the high-resolution collimators and determined which high-resolution images matched the ultrahigh-resolution images in image quality. Eleven patient studies were acquired with both collimator sets for equal time, and observers chose which image set they preferred. Transverse images of brain and liver studies were simulated with varying resolution and counts and subjectively compared. The phantom study indicated that the improvement in resolution led to image quality comparable to increasing the number of counts by a factor of 2.5 to 3.4. The clinical studies showed that the ultrahigh-resolution collimators were preferred in a large majority of the cases. These trends were also seen in the simulation study. These results confirm that higher resolution collimators should be used with multihead SPECT devices. The improvement in resolution more than compensates for the loss in sensitivity, leading to an overall improvement in image quality.

Brain

Improved detection of small cavernous hemangiomas of the liver with high-resolution three-headed SPECT.

The purpose of this study was to review our experience with 99mTc-red blood cell scintigraphy for diagnosis of cavernous hemangiomas of the liver using a new three-headed, high-resolution dedicated SPECT system. Of 19 patients referred with a total of 38 lesions seen on CT, US, or MRI, 14 patients had 24 lesions that were hemangioma-positive with SPECT (all true-positives). Six of these 14 patients also had 9 hemangioma-negative lesions; all were less than or equal to 1.3 cm in size and false-negative. The remaining five patients had hemangioma-negative lesions only (1 false-negative, 4 true-negatives). Two hemangiomas were seen by SPECT that were not detected by CT, US, or MR. The sensitivity for hemangiomas greater than or equal to 1.4 cm. was 100% (20/20). The sensitivity was 33% for lesions 0.9-1.3 cm, and 20% for lesions less than or equal to 0.8 cm. The smallest hemangioma detected was 0.5 cm. These results show a definite improvement in sensitivity with high-resolution triple-headed SPECT over previously reported results using single-headed SPECT. High-resolution SPECT has improved our ability to detect small cavernous hemangiomas of the liver.

Erythrocytes

In vivo SPECT imaging of CNS D-2 dopamine receptors: initial studies with iodine-123-IBZM in humans.

Iodobenzamide (IBZM) is a D-2 dopamine receptor antagonist. In this paper the results of Phase I clinical studies of iodine-123-(123I)IBZM in humans are reported. Preliminary imaging studies, both planar and single-photon emission tomography (SPECT), of no-carrier added [123I]IBZM in humans show specific localization in the basal ganglia of the brain. At 2 hr after an i.v. injection, the brain uptake was 3.72% of the dose, and at 20 hr later the uptake diminished to 0.7%. Radiation dosimetry calculation indicated that the radiation dose to the brain was minimum, 0.039 rad/mCi, while the large intestine wall received the highest dose, 0.28 mrad/mCi. The radiation dosimetry and pharmacology data suggest that this agent is safe for human use.

Adult

Skeletal scintigraphy following incidental trauma.

The significance of antecedent trauma in skeletal scintigraphy was assessed in 503 patients, of whom 241 (46%) had prior fracture or tooth extraction. In patients with sufficiently accurate histories for site-by-site analysis, 33 of 131 fracture sites and 16 of 83 dental-procedure sites were positive scintigraphically. In general, the frequency of scan positivity diminished as the interval between trauma and scanning increased, but a significant number of patients showed prolonged uptake at fracture sites. Several patterns of uptake suggested trauma rather than metastatic disease. Knowledge of a history of trauma is often critical in bone scan interpretation.

Bone Neoplasms

A simple model for anatomic bone scanning studies.

A simple anatomic model for studying the scintigraphic appearance of various skeletal structures is described. The technique makes use of the fact that technitium pyrophosphate uptake in bone occurs by chemisorption to the surface of crystals in the bone matrix. By soaking clean bones in solutions of technetium pyrophosphate they can be rendered radioactive and subsequently studied by various imaging techniques.

Bone and Bones

Thyroid scintigraphy with time-coded aperture.

Coded aperture imaging (CAI) and multiple-view pinhole imaging (MVPI) of the thyroid were compared in 19 patients to determine whether CAI's theoretical advantages of high resolution, high efficiency, freedom from distortion, accurate size representation, and tomographic presentation could be realized in the clinical setting, and to determine whether CAI offers any advantage over conventional MVPI. The coded aperture images were judged better than the pinhole images in five cases, equal in 13 cases, and worse in one case. The major problem with CAI was the long reconstruction time. Further development and an extended clinical trial appear warranted.

Humans

Technical considerations in in vivo thyroid studies.

Radionuclide thyroid studies, although among the oldest of clinical nuclear medicine procedures, continue to show growth and change. In the 7 years since thyroid studies were last reviewed in the Seminars, there have been marked changes in the preferred ways of doing these studies. In the areas of radiopharmaceuticals, 131I remains a useful agent in selected circumstances, but 99mTc-pertechnetate has become the agent of choice for imaging applications. Iodine-123 represents an exciting possibility for the future if problems in cost and radiopurity can be solved. New data on the dosimetry of the various agents allow for more rational choices among them, and useful guidelines can now be given for the use of these radiopharmaceuticals in problem areas such as pregnancy, nursing, and the pediatric age group. The scintillation camera with a pinhole collimator has become the instrument of choice for thyroid imaging, and the use of computers and the availability of systems for fluorescent scanning have added new possibilities for thyroid evaluation. Ancillary techniques such as ultrasound scanning also offer the possibility of improved diagnostic accuracy. These developments are reviewed in the context of clinical studies, together with a discussion of specific clinical applications and a brief look to the future.

Female

Myocardial imaging using emission computed tomography.

Single-photon emission computed tomography (ECT) was evaluated during myocardial studies in dogs. Acute anterior and posterior infarcts were imaged following injection of 99mTc-pyrophosphate or 201Tl. In most cases, tomographic delineation of infarct location and extent correlated with tissue section. The 99mTc images were far superior to the 201Tl images. ECT improves delineation of tracer within the myocardium.

Animals

Myocardial infarct quantification in the dog by single photon emission computed tomography.

Radionuclide techniques for sizing acute myocardial infarction have been hampered by the intrinsic limitations of the scintillation camera. Emission computed tomography can overcome these limitations. Single photon emission computed tomograms of the distribution of technetium-99m pyrophosphate in acute anterior and posterior infarcts were obtained in 16 dogs after death. Tomograms were also obtained in 10 dogs during life without gating. The size of the infarcts was determined by staining gross sections of the heart with nitro blue tetrazolium, dissecting out the infarcted tissue and weighing it. Infarct sizes were determined from the tomographic images and compared with the measured infarct sizes. Good images showing the location and three-dimensional extent of the infarcts were obtained in all dogs. The measured and calculated infarct sizes correlated well (r = 0.85). Comparison of the calculated sizes in the living (non-gated) and dead ("physiologically" gated) animals showed reasonable agreement (r = 0.87). Single photon emission computed tomography is a feasible and useful technique for localizing and sizing acute myocardial infarctions.

Animals

False negative bone scans in neuroblastoma metastatic to the ends of long bones.

Studies of 12 children with neuroblastoma were performed to assess the comparative sensitivity of skeletal radiography and 99mTc pyrophosphate bone scintigraphy in the detection of metastases to the ends of long bones. A total of 18 lesions were detected in six patients. Fourteen were demonstrated only by radiography, whereas four were positive by both methods. In no case was a lesion detected by scintigraphy alone. Small lesion size, lytic radiographic appearance, metaphyseal location, and technical difficulties in imaging the knee all contribute to the high incidenmce of false negative scans. Lesions in two of the nine patients with metastatic disease to bone would have been missed on the basis of bone scans alone. Accordingly, the radiographic skeletal survey seems to remain a necessary part of the neuroblastoma workup.

Bone Neoplasms

An optimized collimator for single-photon computed tomography with a scintillation camera.

The problem of nonuniform response, which is inherent in scintillationcamera emission computed tomography, can be minimized by proper collimator design. A specially fabricated collimator, optimized for emission computed tomography, was designed. This collimator has a calculated full width at half maximum of 1 cm at 15 cm in front of the collimator. When this collimator is used in conjunction with averaged opposed views, excellent uniformity across the reconstruction plane is achievable.

Computers

Gallium-67 scintigraphy in untreated and treated non-hodgkin lymphomas.

One hundred and seventy-four gallium scans of patients with biopsy-proved non-Hodgkin lymphoma were reviewed. When the lymphomas were subdivided into histologic groups, there was a significant difference in detection rates, with 62% of the histiocytic lymphomas being identified, while only 39% of the poorly differentiated lymphocytic lymphomas were detected. There was a high detection rate for lesions in the mediastinum and in extranodal locations. When analyzed with regard to therapy, the detection rate was higher in all histologic subgroups after therapy than before.

Adult

Clinical significance of 99mtechnetium sulfur colloid accumulation in renal transplant patients.

The accumulation of 99mtechnetium sulfur colloid (99mTcSC) was evaluated in 47 studies performed on 19 renal transplant patients by comparing its transplant activity to its bone marrow accumulation. There was a diagnosis of rejection of 21 of 22 studies (96.5%) in which marked transplant accumulation was noted. In 11 studies of patients with a clinical diagnosis of post-transplant acute tubular necrosis (ATN), the transplant activity varied from none to moderate. Rejection developed in 5 of 6 studies with minimal to moderate accumulation. Normally functioning renal transplant patients, or those with ATN and no superimposed rejection, do not show evidence of 99mTcSC accumulation.

Adolescent