[Surveillance of permanent central venous access for hemodialysis].

Central venous catheters have emerged as a valuable alternative for permanent access in hemodialysis. Thanks to steady improvements of materials and design they have been successfully used as bridging solution until another vascular access became available or even long term solution for patients with limited or insuffisant vascular resources. Since the use of central venous catheters is affiliated with a higher dysfunction rate and morbidity, special attention is indicated. This should include regular surveillance, clinical examination and intervention using specific methods, bacteriological exams and regular dialysis quantification. Such a constant quality control followed by strict and adapted rules for catheter handling are essential necessities to reduce catheter-related complications and assure an adequate dialysis.

Catheterization, Central Venous↗

Urea as a marker of adequacy in hemodialysis: lesson from in vivo urea dynamics monitoring.

BACKGROUND: "Dialysis dose," a concept developed by Sargent and Gotch based on urea kinetic modeling, is a useful and recognized tool that is used to quantitate and optimize a dialysis-efficacy program. However, it has been shown that oversimplification of the "dialysis adequacy" concept to the Kt/V index might lead to dramatic underdialysis and subsequent deleterious consequences on morbidity and mortality of dialysis patients. With this perspective, the determination of Kt/V must be very cautious and rely on accurate measurement of postdialysis urea concentration and its use integrated as a tool in a quality-assurance process. METHODS: In this study, we analyzed urea dynamics by means of a blood side (ultrafiltrate) continuous online urea monitoring system interfaced with a two-pool model hosted in a microcomputer. The study was designed to provide instantaneous dialysis performances (body and dialyzer clearances, dialyzer mass transfer coefficient) and to determine the in vivo functional permeability characteristics of the patient [intercompartment urea mass transfer coefficient (Kc)]. Thirteen end-stage renal disease patients (age 54 +/- 16 years; 12 male and 1 female) were studied during nine consecutive dialysis sessions (3 weeks). RESULTS: Urea kinetics obtained from the urea monitoring system fitted closely the urea kinetic modeling prediction, confirming the validity of the double-pool model structure. Effective in vivo urea mass transfer coefficient averaged 912 +/- 235 mL/min/1.73 m2, a value close to those reported with more invasive methods. Large variations ranging from 363 to 1249 mL/min were observed among patients, confirming very large interindividual patient permeability differences. Interestingly, the urea mass transfer coefficient was inversely correlated with the postdialysis rebound values. Intraindividual variations were also noted as a function of time denoting functional changes in urea mass transfer coefficient values. The urea distribution volume was 38.1 +/- 7, 8 L (53 +/- 8% body weight). V1 referring to the extracellular volume and V2 to the intracellular volume were 9 +/- 2 L (13 +/- 2% body weight) and 29.2 +/- 6.6 L (41 +/- 1.3% body wt), respectively. The extracellular/intracellular volume ratio was 0.31 (approximately one third) and was not as usually defined by the paradigm 1/2 ratio. CONCLUSION: Online double-pool urea kinetic modeling gave a new insight in urea kinetic modeling approach. Urea dynamics fit perfectly a double-compartment model structure. Accessible extracellular volume to hemodialysis is smaller than expected. The in vivo urea mass transfer coefficient must be considered as an individual and variable characteristic of ESRD patients that should be taken into consideration when prescribing the hemodialysis schedule.

Adult↗

Intradialytic glucose infusion increases polysulphone membrane permeability and post-dilutional haemodiafiltration performances.

INTRODUCTION: During real-time monitoring of the ultrafiltration coefficient (Kuf) in haemodiafiltration (HDF), it was noticed that the ultrafiltration performance of polysulphone membrane dialysers increased when hypertonic glucose (D50%) was administered through the venous blood return. METHODS: This observation was explored in six non-diabetic chronic dialysis patients during 48 HDF sessions using 1.8 m(2) polysulphone membrane dialysers. In all six patients, 24 sessions were performed with glucose supplementation (as a continuous D50% (500 g/l) infusion at 40 ml/h) and 24 sessions without supplementation. RESULTS: Glucose supplementation led to a marked increase in Kuf from 22.8+/-2.2 (without D50%, n=24) to 32. 1+/-3.9 ml/h/mmHg (with D50%, n=24) (P<0.0001). An increase in percentage reduction ratios for urea and creatinine were also consistently observed during the sessions with glucose administration (from respective mean values of 75+/-5 and 68+/-4% to 79+/-4 and 74+/-10%). Mean double-pool Kt/V, calculated from serum urea concentrations, rose from 1.65+/-0.24 (n=24) to 1.86+/-0.24 (n=24) (P<0.005). Similar results were observed in a subgroup of 18 HDF sessions (nine with glucose and nine without) monitored with an on-line urea sensor of spent dialysate. No detrimental effects were induced at any time. CONCLUSIONS: We conclude that intravenous glucose administration during high-flux HDF using polysulphone membranes increases significantly both ultrafiltration capacity and dialysis dose delivery.

Adult↗

Microbiological purity of dialysate for on-line substitution fluid preparation.

Dialysate purity has become a major concern in recent years since it was shown that low levels of endotoxin in dialysate were able to induce the production of proinflammatory cytokines, which were putatively implicated in the development of dialysis-related pathology. On-line haemodiafiltration (HDF; or haemofiltration) using the dialysate as the source of substitution fluid magnifies this risk and reinforces the critical role of the dialysate quality to be used. In order to virtually abolish the risk related to dialysate contaminants, it is mandatory to ensure the highest purity of the dialysate used in order that the substitution fluid produced satisfies the quality demands of a sterile and pyrogen-free infusion solution. Ultrapure dialysate production is therefore a common need for all on-line systems where substitution fluid is prepared continuously by sterilizing filtration of the dialysate. However, since dialysate purity plays a role in the complex haemocompatibility interaction which occurs during the haemodialysis session, the use of ultrapure dialysate must be considered as a suitable option for all haemodialysis modalities. To achieve this goal, one must keep in mind that ultrapure dialysate and infusate result from a complex chain of production where ultrapurity and/or sterility of the final solution relies on the weakest or worst component of the chain. Reliable production of ultrapure dialysate and infusate relies on several prerequisites: use of ultrapure water, use of clean electrolytic concentrates, implementation of ultrafilters on specifically designed HDF machines, microbiological monitoring of the chain with adequate and sensitive methods, and hygienic handling of the chain including frequent disinfection to reduce the level of contamination and to prevent biofilm formation. When properly done, the safety and reliability of on-line systems have been confirmed in large clinical studies. It is now time to validate the on-line process in large controlled clinical trials.

Bacteria↗

Microbiologic purity of dialysate: rationale and technical aspects.

Dialysate purity has become a major concern in hemodialysis since it has been shown that microbial-derived products were stimulating the production and the release of proinflammatory cytokines in hemodialysis patients. This chronic microinflammatory state induced by hemodialysis has been putatively implicated in the development of dialysis-related pathology. In order to prevent risk related to these offenders and to reduce patient/dialysis interaction, it appears highly desirable to use ultrapure dialysis fluid aiming at sterility and apyrogenicity on a regular basis. Ultrapure dialysate results from a complex chain of production where purity grade relies on the weaker link of this chain. Technical aspects and pitfalls in the production of ultrapure dialysate are summarized in this paper. Production of ultrapure dialysate may be achieved on a routine basis, provided adequate components are used, and hygienic handling is regularly ensured. It includes the use of ultrapure water, clean and or sterile electrolytic concentrates (liquid or powder), implementation of ultrafilters on hemodialysis machines, microbiologic monitoring and hygienic handling of the chain with frequent disinfection. Safety and reliability of ultrapure dialysate production relies on a continuous quality assurance process, where results are coupled to corrective action in a feedback loop process.

Dialysis Solutions↗

Dialock: a new vascular access device for extracorporeal renal replacement therapy. Preliminary clinical results.

BACKGROUND: Vascular access, a vital tool for end-stage renal disease patients, remains a weak component of extracorporeal renal replacement therapy (RRT) and the first cause of morbidity. Permanent catheters proposed as an alternative to permanent AV fistulae are associated with a significant risk of infection. A subcutaneously implantable chamber connected to permanent catheter appears highly desirable to reduce such hazards. METHODS: Dialock, a metallic port-like valve device connected to permanent silicone twin catheters has been developed (Biolink Corp, Middleboro, MA, USA). After being implanted subcutaneously below the clavicle, Dialock provides a linear flow passage to two Silastic catheters placed in the right atrium via the right internal jugular vein. The valve is accessed percutaneously each dialysis session with needle cannulae that functionally convert the device into twin catheters. Interdialytic patency of the catheters is ensured by antithrombotic lock (heparin or low-molecular-weight heparin). RESULTS: Dialock was implanted in 10 ESRD patients (64+/-12 years) under general anaesthesia, with almost immediate use for HD. RRT consisted of three HD sessions per week lasting 4 h; 699 HD sessions were performed. Average duration of use was 5.7 patient-months (1.3-9.6 months). Patient satisfaction was evident in all cases. Three episodes of bacteraemia occurring in the early phase of the study were cured by appropriate antibiotics. No device was removed because of infection. Skin condition at the puncture sites has remained satisfactory in all patients. Nurse training for cannulating was brief (2-3 x). Effective blood flow was 307+/-3.3 ml/min, with a venous pressure of 195+/-39 mmHg and a recirculation rate of 6.7+/-0.8%. Effective Kt/V dp delivered was 1.36+/-0.03 with a nPCR of 1.20+/-0.005 g/kg/day. Haematoma and a small amount of bleeding of the skin puncture sites observed in the initial period of the study were effectively prevented by reducing heparin lock volume. CONCLUSIONS: The Dialock device offers a new and interesting vascular access alternative for haemodialysis bridging the 'gap' between permanent catheters and arteriovenous fistulae. Dialock's place in the vascular access strategy for haemodialysis patients deserves further long-term clinical studies.

Adult↗

Analysis of the influence of the infusion site on dialyser clearances measured in an in vitro system mimicking haemodialysis and haemodiafiltration.

BACKGROUND: Blood flow (QB), dialysate flow (QD), and dialyser characteristics are the three major factors driving dialysis efficacy. Haemodiafiltration has added an increased convective volume to increase efficacy. We aimed to assess the influence of the infusion site of the replacement fluid in an in vitro system emulating haemodiafiltration. METHODS: An in vitro system allowing us to control the dialysate temperature, concentration gradient, the flow of both dialyser sides over a range wider than that compatible with clinic, was set to evaluate the influence of the different parameters on dialysis efficacy. The total ion clearance was used as an accepted method for small molecule clearance assessment. Cellulose triacetate (CT190C, Baxter; FB170U, Nipro) and polysulfone (HF80, Fresenius) dialysers were included in the study. Dialysis as well as on-line diafiltration both with pre- and postdilutional infusion were assessed. The experimental conditions presented in this study included QD 620 and 970 ml/min. The convective flows ranged from 50 to 200 ml/min. RESULTS: For a QD = 620 ml/min and a QB = 350 ml/min the total ion clearance ranged from 269 to 274 for HF80, from 291 to 294 for FB170 and from 294 to 302 for CT190. The variability of the measurements was very low (SD < 1%). Total ion clearance increased by 17-21% when QB was raised from 300 to 400 ml/min. Increasing QD from 420 to 970 ml/min (for QB = 350 ml/min), resulted in an increase in total ion clearance which was more marked at lower QD (from 420 to 620 ml/min) and plateaued thereafter (from 620 to 970 ml/min). Postdilutional on-line diafiltration with 100 ml/min of infusate resulted in an additional increase in total ion clearance of 5.4-8.6%. This increase was proportional to the infused volume. On the contrary, predilutional on-line diafiltration resulted in a decrease in total ion clearance which was also proportional to the infused volume (between -5.1 and -6.9% at 100 ml/min infusion volume and -9.7 to -12.9% at 200 ml/min). CONCLUSIONS: The present in vitro system provided accurate and reproducible results on dialyser clearances. Our experiments confirmed previous studies on the influence of QB and QD on dialyser efficacy. Further, they show that the proportional increase in postdilutional on-line diafiltration is lesser than that previously reported. More importantly, they also show that pre-dilution infusion in high efficiency systems results in a drop in dialyser clearance compared to dialysis alone, again proportional to the infusion rate. Thus, increasing the convective flow may increase dialysis efficacy even more than increasing QD alone. However, the choice of infusion site is crucial to obtaining this benefit in small molecule clearances.

Hemofiltration↗

Evaluation of high-flux hemodiafiltration efficiency using an on-line urea monitor.

On-line urea monitoring of the effluent dialysate offers a real-time assessment of dialysis efficiency and metabolic/nutritional characteristics of hemodialysis patients. Quantitative parameters were evaluated by dialysate urea kinetic modeling (DUKM) with an on-line urea sensor in 23 patients treated by high-flux hemodiafiltration (HDF) (215 sessions of 210 to 240 minutes with a mean blood flow rate of 367 +/- 44 mL/min). Overall, the mean effective Kt/V was 1.52 +/- 0.29, the urea mass removed (22.8 +/- 5.5 g/session or 814 +/- 198 mmol/session), the solute removal index (SRI) 73% +/- 6.1%, and the mean normalized protein catabolic rate (nPCR), 1.15 +/- 0.31 g/kg/day. Blood urea kinetic modeling (BUKM), based on pre- and postsession urea concentrations, using equations from Daugirdas and Garred to calculate equilibrated Kt/V and nPCR, respectively, were in good agreement with DUKM, the differences observed appearing not clinically relevant. The variability of evaluated parameters was verified over consecutive sessions for a mean period of 3 weeks in the entire group. Mean variation in Kt/V was 8%; in urea mass removal, 18%; and in nPCR, 18%. When assessed over 1 week in a subgroup of 13 patients, Kt/V and PCR remained relatively stable, and urea mass removal per- and postsession declined from 23.5 +/- 8.0 g (840 +/- 285 mmol) to 18.7 +/- 6.3 g (667 +/- 225 mmol) from the first to the third session of the week, most likely as a consequence of interdialytic intervals. Predialysis urea concentrations followed the same trend. In the current study, DUKM with on-line urea sensor has confirmed that HDF is a highly efficient renal replacement modality; the variability observed in quantitative parameters supports a need for frequent adequacy monitoring. On-line urea monitoring of effluent dialysate is a simple device that provides the opportunity to tailor treatment to patient needs.

Blood Urea Nitrogen↗

Effective blood flow and recirculation rates in internal jugular vein twin catheters: measurement by ultrasound velocity dilution.

The ultrasound dilution technology (Transonic Systems, Ithaca, NY) is a reliable method to assess blood flow (Qb) and recirculation rates (R) in vascular access during hemodialysis. However, the information available on these parameters for central venous dialysis catheters remains scarce at this point. Real Qb and R were evaluated in 33 well-functioning TwinCath (Medcomp, Harleysville, PA) inserted as mid- or long-term hemodialysis vascular access (mean duration since insertion, 270 +/- 253 days); all were implanted into the right internal jugular vein with their multiperforated distal tips located in the superior vena cava or right atrium. Several types of dialysis machines were used (Monitral and AK100, Hospal-Gambro, Lyon, France; 2008E and 4008E, Fresenius, Bad Homburg, Germany). Real Qb was measured with the ultrasound dilution method and compared with the set Qb (indicated by the dialysis machine); R, also evaluated by ultrasound dilution, was evaluated at various Qb with nonreversed lines; therefore, a total of 121 measures were performed. Arterial and venous pressures (PA and PV) were recorded simultaneously. The 33 measures at a set Qb of 200 mL/min showed a mean effective Qb of 210 +/- 18 mL/min and a mean R of 5.3 +/- 5.3%. At a Qb of 300 mL/min, 33 repeated measures resulted in mean effective Qb of 303 +/- 21 mL/min and R of 8.5 +/- 7.0%; 28 measures performed at a set Qb of 350 mL/min showed that the effective Qb was 336 +/- 24 mL/min and that R was 7.8% +/- 6.7%. Finally, an effective Qb of 372 +/- 26 mL/min and an R of 10.9 +/- 8.6% were found for the 27 measures performed at an indicated Qb of 400 mL/min. The difference between indicated and effective Qb was particularly significant for set Qb equal to or above 350 mL/min (P < 0.001). Variable correlations were observed between obtained parameters: Qb eff and R (r = 0.34), PV and R (r = 0.36), Qb eff and PV (r = 0.78), Qb eff and PA (r = 0.71), and PV and PA (r = 0.53). In conclusion, TwinCath delivers an effective Qb of nearly 375 mL/min when Qb is set at 400 mL/min on most dialysis machines. Mean R in TwinCath varies between 5% and 11% for Qb within the range of 200 to 400 mL/min. In well-functioning TwinCath, the ratio between PV and Qb remains usually below 0.5.

Catheterization, Central Venous↗

On-line haemodiafiltration: state of the art.

Faced with the shortcomings of conventional dialysis on a long-term basis, as illustrated by the dialysis-related pathology, a need for a new strategy exists to improve the overall quality of treatment in end-stage renal failure (ESRF) patients. On-line haemodiafiltration (HDF) seems to be the best therapeutic option to achieve this goal at the present time. By enhancing convective clearances through highly permeable membranes, HDF offers the greatest solute fluxes both for low and higher molecular weight uraemic toxins. As for example, in our routinely performed HDF programme based on 3 weekly sessions lasting 3-4 h each, double-pool urea Kt/V achieved was 1.55+/-0.20 and beta2-microglobulin Kt/V was 0.91. By producing substitution fluid from fresh dialysate, the technique of HDF is simplified and becomes economically affordable. By improving the haemodynamic tolerance, HDF allows more elderly and high risk cardiovascular patients to be treated more safely. By using bicarbonate-buffered infusate, HDF facilitates the correction of acidosis. Both by using ultrapure bicarbonate dialysate and down-regulating the membrane reactivity via a 'protein cake', HDF introduces the first step for a full haemocompatibility concept. Finally, by giving access to virtually unlimited amounts of sterile and non-pyrogenic fluid, HDF should introduce new therapeutic options such as a totally automated and feed-back-controlled machine. Today's on-line HDF is already a step forward to enhance the overall efficacy of renal replacement therapy and to improve the global care of ESRF patients.

Hemodiafiltration↗

Protein catabolic rate over lean body mass ratio: a more rational approach to normalize the protein catabolic rate in dialysis patients.

Protein catabolic rate (PCR), equivalent to dietary protein intake in "stable" dialysis patients, is widely accepted as a marker of their protein nutritional status. PCR is usually established from urea generation rate using urea kinetic modeling (UKM), but the normalizing factor is still a matter of controversy. By convention, PCR is expressed in grams of protein degraded daily divided by the dry body weight (BW) (nPCRBW). To be valid, this implies that dry BW is close to ideal BW and that body composition is preserved with a lean body mass (LBM) over BW ratio near 0.73. Such conditions being infrequently found in dialysis patients, it has been proposed to normalize PCR to ideal BW or to total body water, but these correction factors are not really appropriate. A more rational approach would be to express PCR as the ratio of protein degraded to the kilograms of LBM (nPCRLBM), thus offering the main advantage of directly coupling PCR to changes in protein or nitrogen reserve. In this study, we developed a combined kinetic model of urea and creatinine applied to the midweek dialysis cycle in 66 end-stage renal disease (ESRD) patients. UKM provided Kt/V and PCR, whereas creatinine kinetic modeling (CKM) was used to calculate LBM. Thirty-four patients with a preserved LBM (LBM/dry BW ratio equal to or greater than 0.70; mean ratio, 0.81 +/- 0.11) and with a dry/ideal BW ratio of 1.01 +/- 0.16 had a mean PCR of 1.14 +/- 0.30 g/kg/24 h when normalized to BW (nPCRBW) and of 1.40 +/- 0.30 g/kg/24 h when normalized to LBM (nPCRLBM). In the 32 patients with a reduced LBM (LBM/dry BW ratio, below 0.70; mean ratio, 0.60 +/- 0.09) and dry/ideal BW ratio of 1.11 +/- 0.23, the mean nPCRBW was 0.99 +/- 0.31 g/kg/24 h, whereas nPCRLBM was 1.62 +/- 0.32 g/kg/24 h. For both subgroups, Kt/V was similar, with mean values of 1.76 +/- 0.34 and 1.69 +/- 0.27. Normalizing PCR to LBM offers a double benefit: it compensates for the error induced by abnormal body composition (eg, obese patients) and permits PCR to be adjusted for the decrease in LBM that occurs with age. We propose nPCRLBM as a more rational index to express PCR in dialysis patients.

Aged↗

Central venous dialysis catheter dysfunction.

Central venous catheter dysfunction is a limiting factor in regard to renal replacement therapy efficiency and can thus influence patient morbidity. Early catheter dysfunction is frequently due to mechanical problems such as inadequate positioning, kinking, or constriction, but early fibrin deposition can develop soon after insertion. Delayed dysfunction usually results from thrombus formation, either within the lumen, around the catheter ("fibrin sleeve"), or in the host vein. Catheter dysfunction is suspected clinically or documented by simple imaging studies. It is usually evident and manifested by failure to aspirate blood from the lumen(s), inadequate blood flow and/or high resistance pressures during hemodialysis. However, a more subtle dysfunction may lead to a high recirculation of dialyzed blood and be overlooked if dialysis adequacy is not monitored regularly. Local instillation of a fibrinolytic agent is usually successful in restoring catheter patency. Central venous dialysis catheters present intrinsic limitations consequent to their composition and design, whereas extrinsic limitations result from site of insertion, blood properties and anatomic particularities of a given individual. These characteristics largely determine overall catheter performances. Performance parameters to consider include maximal consistently achievable blood flow rate, resistance to blood flow indicated by arterial and venous pressures during hemodialysis, and blood recirculation rate. Catheter longevity is an important consideration for cuffed catheters implanted for long-term use. The tolerated blood recirculation within central venous dialysis catheters should be below 10% to 15%, and is ideally between 3% to 7% in most clinical settings. Several recent studies confirm that short femoral catheters recirculate significantly more than is desirable. Well functioning and nonreversed internal jugular and subclavian venous catheters have, in general, recirculation rates less than 5%. With regard to various performance criteria, the TwinCath (Medcomp, Harleysville, PA) appears particularly advantageous. In any case, a good catheter maintenance program is of critical importance for the prevention and the early detection of catheter dysfunction.

Catheterization, Central Venous↗

Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement.

The "gold standard" method to evaluate the mass balances achieved during dialysis for a given solute remains total dialysate collection (TDC). However, since handling over 100 liter volumes is unfeasible in our current dialysis units, alternative methods have been proposed, including urea kinetic modeling, partial dialysate collection (PDC) and more recently, monitoring of dialysate urea by on-line devices. Concerned by the complexity and costs generated by these devices, we aimed to adapt the simple "gold standard" TDC method to clinical practice by diminishing the total volumes to be handled. We describe a new system based on partial dialysate collection, the continuous spent sampling of dialysate (CSSD), and present its technical validation. Further, and for the first time, we report a long-term assessment of dialysis dosage in a dialysis clinic using both the classical PDC and the new CSSD system in a group of six stable dialysis patients who were followed for a period of three years. For the CSSD technique, spent dialysate was continuously sampled by a reversed automatic infusion pump at a rate of 10 ml/hr. The piston was automatically driven by the dialysis machine: switched on when dialysis started, off when dialysis terminated and held during the by pass periods. At the same time the number of production cycles of dialysate was monitored and the total volume of dialysate was calculated by multiplying the volume of the production chamber by the number of cycles. Urea and creatinine concentrations were measured in the syringe and the masses were obtained by multiplying this concentration by the total volume. CSSD and TDC were simultaneously performed in 20 dialysis sessions. The total mass of urea removed was calculated as 58038 and 60442 mmol/session (CSSD and TDC respectively; 3.1 +/- 1.2% variation; r = 0.99; y = 0.92x -28.9; P < 0.001). The total mass of creatinine removed was 146,941,143 and 150,071,195 mumol/session (2.2 +/- 0.9% variation; r = 0.99; y = 0.99x + 263; P < 0.001). To determine the long-term clinical use of PDC and CSSD, all the dialysis sessions monitored during three consecutive summers with PDC (during 1993 and 1994) and with CSSD (1995) in six stable dialysis patients were included. The clinical study comparing PDC and CSSD showed similar urea removal: 510 +/- 59 during the first year with PDC and 516 +/- 46 mmol/dialysis session during the third year, using CSSD. Protein catabolic rate (PCR) could be calculated from total urea removal and was 1.05 +/- 0.11 and 1.05 +/- 0.09 g/kg/day with PDC and CSSD for the same periods. PCR values were clearly more stable when calculated from the daily dialysate collections than when obtained with urea kinetic modeling performed once monthly. We found that CSSD is a simple and accurate method to monitor mass balances of urea or any other solute of clinical interest. With CSSD, dialysis efficacy can be monitored at every dialysis session without the need for bleeding a patient. As it is external to the dialysis machine, it can be attached to any type of machine with a very low cost. The sample of dialysate is easy to handle, since it is already taken in a syringe that is sent directly to the laboratory. The CSSD system is currently in routine use in our unit and has demonstrated its feasibility, low cost and high clinical interest in monitoring dialysis patients.

Creatinine↗

Erythropoietin and oxidative stress in haemodialysis: beneficial effects of vitamin E supplementation.

Oxidative stress can produce profound alterations to cellular membrane lipids, impairing cell metabolism and viability. This phenomenon, previously observed in haemodialysis patients, has been proposed as a significant factor in regard to haemodialysis-related shortened red blood cells (RBC) survival. In the present study, several parameters associated with oxidative stress were evaluated in a group of haemodialysis patients either receiving erythropoietin therapy (n = 12, mean erythropoietin dose 88 +/- 24 U/kg/week) or not receiving such therapy (n = 30), and in 38 controls. Malonyldialdehyde (MDA, nmol/ml), an end-product of lipid peroxidation, and RBC antioxidant systems were measured, including RBC alpha-tocopherol (RBC vitamin E, mg/l), RBC glutathione (GSH, nmol/mgHb), and RBC superoxide dismutase activity (SOD, U/mgHb). Plasma vitamin E concentrations were also evaluated. Finally, oral vitamin E supplementation (500 mg daily), an exogenous antioxidant, was administered for 6 months to seven patients from the dialysis group receiving erythropoietin while oxidative parameters were repeatedly evaluated and erythropoietin requirements monitored, in order to appreciate the therapeutic relevance of an antioxidant supplementation. An elevation of serum MDA was observed in all haemodialysis patients and a significant decrease in RBC vitamin E, despite normal serum vitamin E levels. Furthermore, the reduction in RBC vitamin E was more important in patients treated with erythropoietin. Vitamin E supplementation resulted in a significant increase in RBC vitamin E (from 0.3 +/- 0.1 to 1.2 +/- 0.2 mg/l of pellet) and a reduction in erythropoietin dose (from 93 +/- 24 to 74 +/- 26 U/kg/week) while maintaining stable haemoglobin concentrations. These results suggest that the oxidative stress could be one of the resistance factors to erythropoietin response in haemodialysis and that vitamin E supplementation could have a sparing effect on erythropoietin dosage requirement.

Adult↗