Patient-specific analysis of the volume of tissue activated during deep brain stimulation.

Despite the clinical success of deep brain stimulation (DBS) for the treatment of movement disorders, many questions remain about its effects on the nervous system. This study presents a methodology to predict the volume of tissue activated (VTA) by DBS on a patient-specific basis. Our goals were to identify the intersection between the VTA and surrounding anatomical structures and to compare activation of these structures with clinical outcomes. The model system consisted of three fundamental components: (1) a 3D anatomical model of the subcortical nuclei and DBS electrode position in the brain, each derived from magnetic resonance imaging (MRI); (2) a finite element model of the DBS electrode and electric field transmitted to the brain, with tissue conductivity properties derived from diffusion tensor MRI; (3) VTA prediction derived from the response of myelinated axons to the applied electric field, which is a function of the stimulation parameters (contact, impedance, voltage, pulse width, frequency). We used this model system to analyze the effects of subthalamic nucleus (STN) DBS in a patient with Parkinson's disease. Quantitative measurements of bradykinesia, rigidity, and corticospinal tract (CST) motor thresholds were evaluated over a range of stimulation parameter settings. Our model predictions showed good agreement with CST thresholds. Additionally, stimulation through electrode contacts that improved bradykinesia and rigidity generated VTAs that overlapped the zona incerta/fields of Forel (ZI/H2). Application of DBS technology to various neurological disorders has preceded scientific characterization of the volume of tissue directly affected by the stimulation. Synergistic integration of clinical analysis, neuroimaging, neuroanatomy, and neurostimulation modeling provides an opportunity to address wide ranging questions on the factors linked with the therapeutic benefits and side effects of DBS.

Deep Brain Stimulation↗

Failure modes of spinal cord stimulation hardware.

OBJECT: Epidural spinal cord stimulation (SCS) is effective at treating refractory pain. The failure modes of the implanted hardware, however, have not been well studied. A better understanding of this could aid in improving the current procedure or designing future devices. METHODS: The authors reviewed electronic charts and operative reports of 289 patients who had undergone SCS implantation between 1998 and 2002 at the Cleveland Clinic Foundation. Data were collected on demographics, type of hardware, date of implantation procedure, indication for treatment, time to failure, and failure mode. Data were then analyzed to identify significant differences. A total of 577 procedures were performed, 43.5% of which involved revision or removal of SCS hardware. The most common indication was complex regional pain syndrome 1, and this was followed by failed-back surgery syndrome. The median number of procedures per patient was two. Approximately 80% of all leads were the percutaneous type. The majority (62%) of leads were placed in the thoracic region, and 33.5% of all leads required revision. Poor pain relief coverage was the most common indication for revision. Surgically implanted leads broke twice as often as percutaneous leads. In 46% of the patients, hardware revision was required, and multiple revisions were necessary in 22.5%. Three-way ANOVA revealed significant differences in failure mode rates according to location (cervical compared with thoracic, p = 0.037) and failure modes (p = 0.019). Laminotomy leads tended to break and migrate sooner than percutaneous leads. Thoracic leads became infected sooner than cervical leads. CONCLUSIONS: The results of this analysis of SCS hardware failures may be used as a basis for refining surgical technique and designing the next generation of SCS hardware.

Adolescent↗

A preliminary study of transient confusional states following bilateral subthalamic stimulation for Parkinson's disease.

Transient postoperative confusion (POC) occurs in 5-25% of patients following bilateral subthalamic nucleus stimulation. We retrospectively reviewed data on 96 patients who underwent bilateral subthalamic nucleus deep brain stimulation for Parkinson's disease. Nine percent of patients developed POC. There was no significant correlation between age/perioperative factors and POC. The POC group had a significantly higher incidence of depression and frontal-subcortical dysfunction on preoperative evaluation than patients without POC. Postoperative neuropsychological evaluations revealed declines on measures of general cognitive function and memory in the POC group. We provide preliminary evidence that patients with depression and frontal-subcortical dysfunction are more likely to develop POC, and that POC is more often associated with cognitive decline following surgery.

Aged↗

Venous air embolism during deep brain stimulation surgery in an awake supine patient.

Deep brain stimulation (DBS) of the subthalamic nucleus and globus pallidus is used to improve Parkinsonian symptoms and reduce levodopa-induced motor complications in Parkinson's disease (PD). This procedure is usually performed with minimal or no sedation to allow accurate feedback from patients during surgery. Venous air embolism (VAE) has been previously reported in patients undergoing awake neurosurgical procedures for brain tumors or pallidotomy for PD. We describe a case of intraoperative VAE in an awake, supine patient while undergoing DBS surgery for PD who presented with coughing, tachypnea and hypoxemia. The difference in clinical presentation between VAE in awake vs. anesthetized patients is discussed as are intraoperative monitoring techniques and management options.

Cerebral Veins↗

Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease: case report.

OBJECTIVE AND IMPORTANCE: Deep brain stimulation (DBS) is an accepted treatment for patients with Parkinson's disease refractory to medication. The efficacy of this therapy has led to increasing numbers of patients receiving DBS implants. Importantly, physicians caring for patients with implantable neurostimulators must be aware of treatment guidelines for these patients, including the use of therapeutic ultrasound, diathermy, and imaging studies such as magnetic resonance imaging (MRI). CLINICAL PRESENTATION: We describe a case of serious, permanent neurological injury secondary to a radiofrequency lesion produced by heating of a DBS electrode associated with MRI of the lumbar spine in a patient with Parkinson's disease. INTERVENTION: MRI may be performed safely in patients with DBS devices only by following the specific guidelines of the manufacturer. The generalization of these conditions to other neurostimulation system positioning schemes, other scanners, and other imaging scenarios can lead to significant patient injuries. CONCLUSION: To prevent catastrophic incidents, the manufacturer's guidelines should be followed carefully because they are known to result in the safe performance of MRI examinations of patients with neurostimulation systems used for DBS.

Brain Injuries↗

Frameless stereotaxy using bone fiducial markers for deep brain stimulation.

OBJECT: Functional neurosurgical interventions such as deep brain stimulation (DBS) are traditionally performed with the aid of a stereotactic frame. Although frameless techniques have been perceived as less accurate, data from a recent phantom study of a modified frameless approach demonstrated a laboratory accuracy exceeding that obtained using a common frame system. The present study was conducted to evaluate the accuracy of a frameless system in routine clinical use. METHODS: Deep brain stimulation leads were implanted in 38 patients by using a skull-mounted trajectory guide and an image-guided workstation. Registration was accomplished with bone fiducial markers. Final lead positions were measured on postoperative computerized tomography scans and compared with the planned lead positions. The accuracy of the Leksell frame within the clinical situation has been reported on in a recent study; these raw data served as a comparison data set. The difference between expected and actual lead locations in the x plane was 1.4 mm in the frame-based procedure and 1.6 mm in the frameless procedure. Similarly, the difference in the y plane was 1.6 mm in the frame-based system and 1.3 mm in the frameless one. The error was greatest in the z plane, that is, 1.7 mm in the frame-based method and 2 mm in the frameless system. Multivariate analysis of variance demonstrated no statistically significant difference in the accuracy of the two methods. CONCLUSIONS: The accuracy of the frame-based and frameless systems was not statistically significantly different (p = 0.22). Note, however, that frameless techniques offer advantages in patient comfort, separation of imaging from surgery, and decreased operating time.

Deep Brain Stimulation↗

Recovery of pain control by intensive reprogramming after loss of benefit from motor cortex stimulation for neuropathic pain.

INTRODUCTION: Motor cortex stimulation (MCS) may serve as an adjunct in managing neuropathic pain after other conservative and interventional methods have failed. However, the magnitude and duration of the benefit are highly variable, with a significant percentage of patients losing pain relief over time. We investigated whether intensive reprogramming could recapture the beneficial effects of MCS. METHODS: Six patients who had previously undergone MCS implantation for neuropathic pain but had lost benefit were brought back for 1-5 days of intensive reprogramming. Four patients were evaluated as inpatients while the others were seen as outpatients during multiple visits over several days. Several hours a day were spent with each patient. Patients completed visual analog scale (VAS) ratings at intervals throughout the reprogramming period to judge effectiveness of stimulation. Pre- and postadjustment VAS were compared using a paired t test. RESULTS: The patients' average age was 50 years (range 26-71). The diagnoses were trigeminal neuropathic pain (2 patients), complex regional pain syndrome I (2), phantom limb pain (1) and poststroke pain (1). The mean duration of pain was 6 years. The MCS benefit had initially lasted for a mean of 7.16 months (range 2-18 months). After reprogramming, 5 of 6 patients experienced improvement in pain. Average VAS scores decreased from 7.44 to 2.28 (p < 0.001) in those patients who responded to reprogramming. The average stimulation parameters in these patients were 5 V amplitude (range 1.7-10), 313 micros pulse width (range 240-390) and frequency of 84 Hz (range 55-130). Three patients experienced seizures during reprogramming. The mean seizure threshold was 8.9 V. No patient experienced seizures at their therapeutic settings. Pain control has been maintained after discharge. CONCLUSION: Intensive reprogramming can recapture the benefit of MCS in patients who have lost pain control. The use of broad dipoles using two contacts rather than one contact of the 1 x 4 electrode array improved the ability to recapture beneficial stimulation. There is a significant risk of seizures during aggressive reprogramming.

Adult↗

Frameless localization for functional neurosurgical procedures: a preliminary accuracy study.

BACKGROUND: Targeting for functional stereotactic procedures is traditionally carried out in a noninteractive fashion, without real-time positional feedback. In addition, stereotactic frames are uncomfortable for patients and may impede intraoperative neurological evaluation. As an initial step toward a fully frameless approach to functional surgery, we have investigated the use of an image-guided microdrive coupled to a stereotactic frame system. METHODS: For initial laboratory tests, a stereotactic phantom was imaged using high-resolution CT scanning. Three representative targets were chosen within the phantom. Targeting was carried out in the usual fashion using the StealthStation planning suite, utilizing the Radionics CRW system. An LED-equipped reference arc was attached to the CRW base ring. Registration of the base ring was accomplished using a spherical probe. A custom-built microdrive was fitted with an LED array, mounted on the CRW arc and tracked by the StealthStation. The distance between the Stealth real-time localization and the CRW localization was measured on-screen. To evaluate the accuracy of the system in the operating room, a similar procedure was carried out in 13 functional neurosurgical operations (pallidotomy or deep brain stimulator placement). RESULTS: Errors of localization in the laboratory setting ranged from 0.53 to 0.70 mm. In 11 operative cases, the average difference between the CRW localization and the Stealth localization was 1.77 mm. In the remaining 2 cases, equipment malfunction prevented measurement of localization error. CONCLUSIONS: Frameless image-guided localization compares favorably to targeting performed noninteractively. In addition, real-time positional feedback confers advantages in target region visualization and confidence in placement of lesions and stimulators for functional procedures. With small improvements in accuracy and system reliability, fully frameless functional procedures could be safely carried out.

Deep Brain Stimulation↗

The application accuracy of a skull-mounted trajectory guide system for image-guided functional neurosurgery.

OBJECTIVE: Frameless image guided systems have traditionally been perceived as being less accurate than stereotactic frames, limiting their adoption for trajectory-based procedures such as deep brain stimulator placement which require submillimetric accuracy. However, some studies have suggested that high degrees of accuracy are attainable with optical localization systems. We evaluated the application accuracy of a skull-mounted trajectory guide coupled to an optical image-guided surgery system in a laboratory setting. MATERIALS AND METHODS: A plastic skull phantom was fitted with five fiducial markers rigidly attached via self-drilling bone screws. Varying MRI and CT imaging protocols were obtained at 25 different centers. A metal disc marked in 1-mm increments was placed at the expected target point. Following registration and alignment of the trajectory guide, radial and depth localization errors were measured. A total of 560 measurements were obtained and detailed statistical analyses were performed. RESULTS: Mean localization error was 1.25 mm with a 95% confidence interval of 2.7 mm and a 99.9% confidence interval of 4.0 mm. These values were significantly lower than those published for the two most widely used frame systems (p<0.001). CONCLUSIONS: Accuracy of image-guided localization using a rigid trajectory guide can meet or exceed that achievable with a stereotactic frame.

Humans↗

Anatomy and physiology of chronic pain.

Although much has been accomplished in the past several decades, treatment of chronic pain remains imperfect. This article presents the anatomy and physiology of the pain system along with the neurobiologic changes that occur in the establishment and maintenance of chronic pain states.

Brain↗