Abstract

BACKGROUND: Targeting for functional stereotactic procedures is traditionally carried out in a noninteractive fashion, without real-time positional feedback. In addition, stereotactic frames are uncomfortable for patients and may impede intraoperative neurological evaluation. As an initial step toward a fully frameless approach to functional surgery, we have investigated the use of an image-guided microdrive coupled to a stereotactic frame system. METHODS: For initial laboratory tests, a stereotactic phantom was imaged using high-resolution CT scanning. Three representative targets were chosen within the phantom. Targeting was carried out in the usual fashion using the StealthStation planning suite, utilizing the Radionics CRW system. An LED-equipped reference arc was attached to the CRW base ring. Registration of the base ring was accomplished using a spherical probe. A custom-built microdrive was fitted with an LED array, mounted on the CRW arc and tracked by the StealthStation. The distance between the Stealth real-time localization and the CRW localization was measured on-screen. To evaluate the accuracy of the system in the operating room, a similar procedure was carried out in 13 functional neurosurgical operations (pallidotomy or deep brain stimulator placement). RESULTS: Errors of localization in the laboratory setting ranged from 0.53 to 0.70 mm. In 11 operative cases, the average difference between the CRW localization and the Stealth localization was 1.77 mm. In the remaining 2 cases, equipment malfunction prevented measurement of localization error. CONCLUSIONS: Frameless image-guided localization compares favorably to targeting performed noninteractively. In addition, real-time positional feedback confers advantages in target region visualization and confidence in placement of lesions and stimulators for functional procedures. With small improvements in accuracy and system reliability, fully frameless functional procedures could be safely carried out.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jaimie M Henderson. 2004-10-04. Frameless localization for functional neurosurgical procedures: a preliminary accuracy study.. https://doi.org/10.1159/000081345

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Lower stimulation frequency can enhance tolerability and efficacy of pallidal deep brain stimulation for dystonia.

We report the case of a patient with medically refractory primary dystonia who was treated with bilateral pallidal deep brain stimulation. Stimulation at 130 Hz or higher, by means of the more ventral contacts generated capsular side effects, which made their use impractical. Consequently, the patient was treated for 9 months at 130 to 185 Hz, by means of the more dorsal contacts, achieving modest results. By reducing the stimulation frequency to 80 Hz, we were able to activate the ventral contacts without inducing side effects. Within days, the patient experienced a dramatic improvement in function that has persisted for 1 year. A further reduction in stimulation frequency to 60 Hz resulted in a worsening of his symptoms. We conclude that chronic stimulation at frequencies of <100 Hz may be efficacious in dystonia and may enhance the tolerability of stimulation by means of contacts that are positioned posteroventrally within the internal globus pallidus, nearer the internal capsule.

Deep Brain Stimulation↗

[Surgery for Parkinson's disease].

Surgery for Parkinson's Disease (PD) is being increasingly used. The main reason for this renewal in surgical treatment for PD is the "deep brain stimulation" (DBS) that replaced the previously used stereotactic lesions in most centers. DBS allows a focal specific electrical stimulation of basal ganglia target instead of an irreversible lesion. Mainly bilateral DBS of the nucleus subthalamicus is now an established surgical treatment for PD. But DBS of the Globus pallidus internus and of the thalamus should still be considered in selected patients. DBS is an efficient treatment for motor complication of PD that can no longer be controlled by drug treatment. Dyskinesia, bradykinesia, tremor and rigor can be improved by DBS and the medication can be reduced. It is still unclear, however, how the improvement in motor symptoms affects quality of life in the long term. Furthermore, patients with severe cognitive and psychiatric symptoms as well as patients with severe axial symptoms should not be operated since these symptoms may worsen after surgery.

Deep Brain Stimulation↗

A unique episode of REM sleep behavior disorder triggered during surgery for Parkinson's disease.

REM sleep behavior disorder (RBD) is characterized by vigorous movements during REM sleep. Here, the authors report the case of a patient who presented such a disorder immediately after the implantation of the definitive electrode for left subthalamic stimulation. Interestingly, this was and has remained a unique episode in his medical history. It was found that a microlesion in or near the upper part of the pars compacta of the substantia nigra was very likely responsible for this phenomenon.

Deep Brain Stimulation↗