Encapsulated chondrocyte response in a pulsatile flow bioreactor.

We have developed a bioreactor-based millifluidic technique that allows for dynamic culture conditions and measurement of the fluid flow impinging upon a three-dimensional tissue engineering scaffold. Chondrocytes in scaffolds have been shown to require mechanical stimulation to produce an extracellular matrix that resembles native cartilage. This study investigates the effect of pulsatile flow on chondrocyte response in a model poly(ethylene glycol) dimethacrylate hydrogel. Bovine chondrocytes were encapsulated in the hydrogel and cultured for 7, 14 and 21 days at pulsatile flow frequencies of 0.5 Hz (15ml/min) and 1.5Hz (17ml/min). The scaffolds cultured under dynamic conditions were compared to those cultured under static (non-flow) conditions. Quantitative real-time reverse transcription polymerase chain reaction was used to quantify collagen type I, collagen type II and aggrecan gene copy numbers as markers for chondrocyte phenotypic expression. Histological sections stained with hematoxylin & eosin, and Alcian blue confirmed chondrocyte morphology and matrix formation. Interestingly, regulation of the collagen type II gene was particularly sensitive to the flow conditions. The understanding of the cell response to encapsulation and flow could be used to identify the appropriate culture conditions necessary to design and develop hydrogel carriers to promote the formation of extracellular matrix as well as to further our knowledge of chondrocyte mechanobiology.

Animals↗

Engineering controllable anisotropy in electrospun biodegradable nanofibrous scaffolds for musculoskeletal tissue engineering.

Many musculoskeletal tissues exhibit significant anisotropic mechanical properties reflective of a highly oriented underlying extracellular matrix. For tissue engineering, recreating this organization of the native tissue remains a challenge. To address this issue, this study explored the fabrication of biodegradable nanofibrous scaffolds composed of aligned fibers via electrospinning onto a rotating target, and characterized their mechanical anisotropy as a function of the production parameters. The characterization showed that nanofiber organization was dependent on the rotation speed of the target; randomly oriented fibers (33% fiber alignment) were produced on a stationary shaft, whereas highly oriented fibers (94% fiber alignment) were produced when rotation speed was increased to 9.3m/s. Non-aligned scaffolds had an isotropic tensile modulus of 2.1+/-0.4MPa, compared to highly anisotropic scaffolds whose modulus was 11.6+/-3.1MPa in the presumed fiber direction, suggesting that fiber alignment has a profound effect on the mechanical properties of scaffolds. Mechanical anisotropy was most pronounced at higher rotation speeds, with a greater than 33-fold enhancement of the Young's modulus in the fiber direction compared to perpendicular to the fiber direction when the rotation speed reached 8m/s. In cell culture, both the organization of actin filaments of human mesenchymal stem cells and the cellular alignment of meniscal fibroblasts were dictated by the prevailing nanofiber orientation. This study demonstrates that controllable and anisotropic mechanical properties of nanofibrous scaffolds can be achieved by dictating nanofiber organization through intelligent scaffold design.

Absorbable Implants↗

Fabrication and characterization of six electrospun poly(alpha-hydroxy ester)-based fibrous scaffolds for tissue engineering applications.

The most common synthetic biodegradable polymers being investigated for tissue engineering applications are FDA approved, clinically used poly(alpha-hydroxy esters). To better assess the applicability of the electrospinning technology for scaffold fabrication, six commonly used poly(alpha-hydroxy esters) were used to prepare electrospun fibrous scaffolds, and their physical and biological properties were also characterized. Our results suggest that specific, optimized fabrication parameters are required for each polymer to produce scaffolds that consist of uniform structures morphologically similar to native extracellular matrix. Scanning electron microscopy (SEM) revealed a highly porous, three-dimensional structure for all scaffolds, with average fiber diameter ranging from 300nm to 1.5microm, depending on the polymer type used. The poly(glycolic acid) (PGA) and poly(d,l-lactic-co-glycolic acid 50:50) (PLGA5050) fibrous structures were mechanically stiffest, whereas the poly(l-lactic acid) (PLLA) and poly(epsilon-caprolactone) (PCL) scaffolds were most compliant. Upon incubation in physiological solution, severe structural destruction due to polymer degradation was found in the PGA, poly(d,l-lactic acid) (PDLLA), PLGA5050, and poly(d,l-lactic-co-glycolic acid 85:15) (PLGA8515) fibrous scaffolds, whereas PLLA and PCL fibrous scaffolds maintained a robust scaffold structure during the same time period, based on macroscopic and SEM observations. In addition, PLLA scaffolds supported the highest rate of proliferation of seeded cells (chondrocytes and mesenchymal stem cells) than other polymeric scaffolds. Our findings showed that PLLA and PCL based fibrous scaffolds exhibited the most optimal structural integrity and supported desirable cellular response in culture, suggesting that such scaffolds may be promising candidate biomaterials for tissue engineering applications.

Animals↗

Evaluation of the anterior cruciate ligament, medial collateral ligament, achilles tendon and patellar tendon as cell sources for tissue-engineered ligament.

This study investigated four different connective tissue cell types to determine which cell type should be the source for seeding a tissue-engineered anterior cruciate ligament (ACL) replacement. Cells derived from the ACL, medial collateral ligament (MCL), achilles tendon (AT), and patellar tendon (PT) of New Zealand White rabbits were isolated and cultured. Each cell type was cultured in vitro after seeding on three-dimensional (3-D) braided polymer scaffolds and on tissue culture polystyrene that served as a control. Samples were evaluated and compared for their morphology, proliferation, and gene expression of fibronectin, type I and type III collagen. Scanning electron microscopy (SEM) photomicrographs verified cell attachment of all four types of connective tissue fibroblasts to the scaffolds. Preliminary results comparing proliferation indicate that cells obtained from the PT and AT have the fastest proliferation. Whereas gene expression of the phenotypic markers measured using real-time reverse transcription polymerase chain reaction (RT-PCR) indicates ACL cells have the highest gene expression for the matrix markers. This leads to the question of which cell type should be the cell source for tissue-engineering of ligament, the highly proliferating cells or the differentiated matrix producing cells. This study would suggest that ACL differentiated matrix producing cells are the most suitable cells for further study and development of a tissue-engineered ligament.

Achilles Tendon↗

Tissue engineering scaffolds based on photocured dimethacrylate polymers for in vitro optical imaging.

Model tissue engineering scaffolds based on photocurable resin mixtures with sodium chloride have been prepared for optical imaging studies of cell attachment. A photoactivated ethoxylated bisphenol A dimethacrylate was mixed with sieved sodium chloride (NaCl) crystals and photocured to form a cross-linked composite. Upon soaking in water, the NaCl dissolved to leave a porous scaffold with desirable optical properties, mechanical integrity, and controlled porosity. Scaffolds were prepared with salt crystals that had been sieved to average diameters of 390, 300, 200, and 100 microm, yielding porosities of approximately 75 vol %. Scanning electron microscopy and X-ray microcomputed tomography confirmed that the pore size distribution of the scaffolds could be controlled using this photocuring technique. Compression tests showed that for scaffolds with 84% (by mass fraction) salt, the larger pore size scaffolds were more rigid, while the smaller pore size scaffolds were softer and more readily compressible. The prepared scaffolds were seeded with osteoblasts, cultured between 3 and 18 d, and examined using confocal microscopy. Because the cross-linked polymer in the scaffolds is an amorphous glass, it was possible to optically image cells that were over 400 microm beneath the surface of the sample.

Animals↗

The ABJS Nicolas Andry Award: Tissue engineering of bone and ligament: a 15-year perspective.

Musculoskeletal repair is a major challenge for orthopaedic surgeons. The burden of repair is compounded by supply constraints and morbidity associated with autograft and allograft tissue. We report 15 years of research regarding tissue engineering and biological substitutes for bone and ligaments. Our approach has focused on biomaterial selection, scaffold development, cell selection, cell/material interaction, and growth factor delivery. We have extensively tested poly(ester), poly(anhydride), poly(phosphazene) derivatives, and composite materials using biocompatibility, degradation, and mechanical analyses for bone and ligament tissue engineering. We have developed novel three-dimensional matrices with a pore structure and mechanical properties similar to native tissue. We also have reported on the attachment, growth, proliferation, and differentiation of cells cultured on several scaffolds. Through extensive molecular analysis, in vitro culture condition analysis, and in vivo evaluation, our findings provide new methods of bone tissue regeneration using three-dimensional tissue engineered scaffolds, bioactive bone cement composite materials, and three-dimensional tissue engineered scaffolds for ligament regeneration.

Animals↗

A double-blind, randomized, parallel-group, flexible-dose study to evaluate the tolerability, efficacy and effects of treatment discontinuation with escitalopram and paroxetine in patients with major depressive disorder.

This multinational, randomized, double-blind, flexible-dose study evaluated the short- and long-term antidepressant tolerability and efficacy of escitalopram and paroxetine. Tolerability was assessed by monitoring adverse events throughout the study, and discontinuation events during brief treatment interruption and tapered withdrawal. Discontinuation-emergent effects were evaluated in two separate double-blind periods. First, to mimic the consequences of non-compliance, patients were randomized to one of two treatment interruption periods (placebo-substitution for 3-5 days). Second, patients were randomized to a 1-2-week tapered withdrawal period randomly scheduled between weeks 28 and 31. The pre-specified primary efficacy endpoint was the mean change from baseline in total Montgomery-Asberg Depression Rating Scale (MADRS) score at week 8, using the principle of last observation carried forward. A total of 323 patients entered 8 weeks of double-blind treatment and received at least one flexible dose of escitalopram (10-20 mg/day) or paroxetine (20-40 mg/day). Patients who demonstrated evidence of a significant clinical improvement (Clinical Global Impression-Improvement of 1 or 2) at week 8 entered a 19-week, double-blind maintenance period during which they were treated with the same dose they received at week 8, followed by a 1-2-week tapered withdrawal period. A total of 89 patients (28%) withdrew during the study; significantly (P<0.01) more patients withdrew from the paroxetine group (34%) than from the escitalopram group (21%), and significantly (P<0.05) more paroxetine patients withdrew due to lack of efficacy. The mean MADRS total score improved for both treatment groups from baseline to week 8, with no statistical difference between groups. In severely depressed patients (baseline MADRS total score >or=30), escitalopram was superior (P<0.05) to paroxetine at week 27 (end of maintenance treatment). There was a high prevalence of sexual dysfunction at baseline: the mean Arizona Sexual Experience Scale (ASEX) score was approximately 20 points in both treatment groups. Mean total ASEX scores increased slightly above baseline values during the acute period and declined slightly below baseline values towards the end of the maintenance period. During taper and cessation of treatment, patients in the paroxetine group demonstrated significantly more discontinuation symptoms relative to escitalopram based on the Discontinuation Emergent Signs and Symptoms scores.

Citalopram↗

Anterior cruciate ligament regeneration using braided biodegradable scaffolds: in vitro optimization studies.

The anterior cruciate ligament (ACL) is the most commonly injured intra-articular ligament of the knee, and limitations in existing reconstruction grafts have prompted an interest in tissue engineered solutions. Previously, we reported on a tissue-engineered ACL scaffold fabricated using a novel, three-dimensional braiding technology. A critical factor in determining cellular response to such a graft is material selection. The objective of this in vitro study was to optimize the braided scaffold, focusing on material composition and the identification of an appropriate polymer. The selection criteria are based on cellular response, construct degradation, and the associated mechanical properties. Three compositions of poly-alpha-hydroxyester fibers, namely polyglycolic acid (PGA), poly-L-lactic acid (PLLA), and polylactic-co-glycolic acid 82:18 (PLAGA) were examined. The effects of polymer composition on scaffold mechanical properties and degradation were evaluated in physiologically relevant solutions. Prior to culturing with primary rabbit ACL cells, scaffolds were pre-coated with fibronectin (Fn, PGA-Fn, PLAGA-Fn, PLLA-Fn), an important protein which is upregulated during ligament healing. Cell attachment and growth were examined as a function of time and polymer composition. While PGA scaffolds measured the highest tensile strength followed by PLLA and PLAGA, its rapid degradation in vitro resulted in matrix disruption and cell death over time. PLLA-based scaffolds maintained their structural integrity and exhibited superior mechanical properties over time. The response of ACL cells was found to be dependent on polymer composition, with the highest cell number measured on PLLA-Fn scaffolds. Surface modification of polymer scaffolds with Fn improved cell attachment efficiency and effected the long-term matrix production by ACL cells on PLLA and PLAGA scaffolds. Therefore based on the overall cellular response and its temporal mechanical and degradation properties in vitro, the PLLA braided scaffold pre-coated with Fn was found to be the most suitable substrate for ACL tissue engineering.

Absorbable Implants↗

Fiber-based tissue-engineered scaffold for ligament replacement: design considerations and in vitro evaluation.

The anterior cruciate ligament (ACL) is the major intraarticular ligamentous structure of the knee, which functions as a joint stabilizer. It is the most commonly injured ligament of the knee, with over 150,000 ACL surgeries performed annually in the United States. Due to limitations associated with current grafts for ACL reconstruction, there is a significant demand for alternative graft systems. We report here the development of a biodegradable, tissue-engineered ACL graft. Several design parameters including construct architecture, porosity, degradability, and cell source were examined. This graft system is based on polymeric fibers of polylactide-co-glycolide 10:90, and it was fabricated using a novel, three-dimensional braiding technology. The resultant micro-porous scaffold exhibited optimal pore diameters (175-233 microm) for ligament tissue ingrowth, and initial mechanical properties of the construct approximate those of the native ligament.

Absorbable Implants↗

Giant tumefactive perivascular spaces.

BACKGROUND AND PURPOSE: The brain perivascular spaces (PVSs) are pial-lined, interstitial fluid-filled structures that accompany penetrating arteries. When enlarged, they may cause mass effect and can be mistaken for more ominous pathologic processes. The purpose of this study was to delineate the broad clinical and imaging spectrum of this unusual condition. METHODS: Thirty-seven cases of giant PVSs were identified from 1988 to 2004 and were retrospectively reviewed. Clinical data collected included patient demographics, presenting symptoms, and follow-up. Histopathologic data were reviewed when available. Images were evaluated for size and location of the giant PVSs, associated mass effect, hydrocephalus, adjacent white matter changes, and contrast enhancement. RESULTS: There were 24 men and 13 women with an age range of 6-86 years, (mean 46 years). The most common presenting feature was headache (15 patients). Thirty-two cases had multilocular clusters of variably sized cysts. Five lesions were unilocular. All lesions had signal intensity comparable to CSF and did not enhance. The most common location for the giant PVSs was the mesencephalothalamic region (21/36). Fourteen were located in the cerebral white matter; two were in the dentate nuclei. Nine giant mesencephalothalamic PVSs had associated hydrocephalus, which required surgical intervention. CONCLUSION: Giant tumefactive PVSs most often appear as clusters of variably sized cysts that are isointense relative to CSF and do not enhance. They are most common in the mesencephalothalamic region and may cause hydrocephalus. Although they may have striking mass effect, giant PVSs should not be mistaken for neoplasm or other diseases.

Adolescent↗

Synthesis and characterization of PEG dimethacrylates and their hydrogels.

Facile synthesis and detailed characterization of photopolymerizable and biocompatible poly(ethylene glycol) dimethacrylates (PEGDM) and poly(ethylene glycol) urethane-dimethacrylates (PEGUDM) are described. Poly(ethylene glycol)s of various molecular masses (M(n) = 1000 to 8000 g/mol) were reacted with methacrylic anhydride or with 2-isocyanatoethyl methacrylate to form PEGDMs and PEGUDMs, respectively. PEGDMs were also prepared by a microwave-assisted route to achieve fast reaction conversions under solvent free conditions. Combined analyses of (1)H NMR and MALDI-TOF MS confirmed the formation of prepolymers of high purity and narrow mass distribution (PD < 1.02). Aqueous solutions of the PEGDMs and PEGUDMs (10% and 20% by mass fraction) were photopolymerized to yield hydrogels. Bovine chondrocytes, seeded in the hydrogels, were used to assess the biocompatibility. Preliminary rheology and uniaxial compression measurements showed varied mechanical response, and biocompatibility studies showed that cells are completely viable in both types of hydrogels after two weeks.

Animals↗

Central neurocytoma.

Explore the source record for details and available documents.

Brain Neoplasms↗