PubMed Health⌕ Search

Biomedical subjects

James P Reilly

Publications and source records attributed to James P Reilly.

At least 19 recordsLinked to original sources

A top-down/bottom-up study of the ribosomal proteins of Caulobacter crescentus.

Ribosomes from the Gram-negative alpha-proteobacterium Caulobacter crescentus were isolated using standard methods. Proteins were separated using a two-dimensional liquid chromatographic system that allowed the analysis of whole proteins by direct coupling to an ESI-QTOF mass spectrometer and of proteolytic digests by a number of mass spectrometric methods. The masses of 53 of 54 ribosomal proteins were directly measured. Protein identifications and proposed post-translational modifications were supported by proteolysis with trypsin, endoprotease Glu-C, and exoproteases carboxypeptidases Y and P. Tryptic peptide mass maps show an average sequence coverage of 62%, and carboxypeptidase C-terminal sequence tagging provided unambiguous identification of the small, highly basic proteins of the large subunit. C. crescentus presents some post-translational modifications that are similar to those of Escherichia coli (e.g., N-terminal acetylation of S9 and S18) along with some unique variations, such as a near absence of L7 and extensive modification of L11. The comprehensive description of this organism's ribosomal proteome provides a foundation for the study of ribosome structure, dependence of post-translational modifications on growth conditions, and the evolution of subcellular organelles.

Bacterial Proteins↗

Two dimensional liquid phase separations of proteins using online fractionation and concentration between chromatographic dimensions.

Multi-dimensional liquid chromatography is often presented as an alternative to two-dimensional (2-D) gel electrophoresis for separating complex protein mixtures. The vast majority of analytical-scale 2-D LC systems have employed either off-line fractionation or stepped gradients in the first dimension separation. The latter severely restrict flexibility in setting up the first dimension gradient. We propose a novel two-dimensional LC system that employs online fractionation of proteins into a series of small reversed phase trapping columns. These traps effectively decouple the two separation dimensions and avoid problems associated with off-line fraction collection. Flexibility in determining the gradient programs for the two separations is thus enhanced. The reduced diameter of the trapping columns concentrates analyte between chromatographic dimensions. The apparatus is coupled with online electrospray time-of-flight mass spectrometry to characterize ribosomal proteins of Caulobacter crescentus.

Chemical Fractionation↗

A non-nephrotoxic gentamicin congener that retains antimicrobial efficacy.

Aminoglycoside antibiotics, although of major clinical importance in the treatment of serious Gram- negative infections and a potential therapeutic agent in the amelioration of diseases that are characterized by premature stop mutations, are associated with a high incidence of acute renal failure. With the use of HPLC techniques, the four components (congeners) of gentamicin, the most commonly used aminoglycoside, were isolated and characterized. Described here is a congener with minimal cytotoxicity in cell culture and animal studies that retained normal bactericidal properties in both Bacillus subtilis and a multidrug-resistant form of Klebsiella pneumoniae. Furthermore, in animal studies, this congener failed to induce the functional and pathologic changes that are characteristic of gentamicin nephrotoxicity that is seen with the native compound. Finally, internalization of this non-nephrotoxic component was unaltered, but the subcellular distribution was different from native gentamicin or the other three cytotoxic congeners. These studies have identified a component of the native gentamicin congener mixture that retains its bactericidal properties with minimal or no apparent nephrotoxicity.

Animals↗

A nutrient uptake role for bacterial cell envelope extensions.

Bacteria exist in a variety of morphologies, but the relationship between cellular forms and biological functions remains poorly understood. We show that stalks (prosthecae), cylindrical extensions of the Caulobacter crescentus cell envelope, can take up and hydrolyze organic phosphate molecules and contain the high-affinity phosphate-binding protein PstS, but not PstA, a protein that is required for transport of phosphate into the cytoplasm. Therefore, uptake, hydrolysis, and periplasmic binding of a phosphate source can take place in the stalk, but high-affinity import must take place in the cell body. Furthermore, by using analytical modeling, we illustrate the biophysical advantage of the stalk as a morphological adaptation to the diffusion-limited, oligotrophic environments where C. crescentus thrives. This advantage is due to the fact that a stalk is long and thin, a favorable shape for maximizing contact with diffusing nutrients while minimizing increases in both surface area and cell volume.

Animals↗

Structures of alpha-type ions formed in the 157 nm photodissociation of singly-charged peptide ions.

One hundred fifty-seven nm photodissociation of singly-charged peptide ions induces the cleavage of alpha-carbon to carbonyl-carbon bonds along the backbone. a(n) + 1 radical ions are observed as the primary photolysis products of peptides with N-terminal arginines in a linear ion trap mass spectrometer. The radical elimination pathways undertaken by the a(n) + 1 radical ions to form more stable even-electron species are studied in hydrogen-deuterium (H/D) exchange experiments. Two types of a(n) ions along with d-type ions are observed as secondary elimination products. The relative abundance of each depends on the C-terminal residue of the radical fragment ion.

Amino Acid Sequence↗

A computational approach toward label-free protein quantification using predicted peptide detectability.

We propose here a new concept of peptide detectability which could be an important factor in explaining the relationship between a protein's quantity and the peptides identified from it in a high-throughput proteomics experiment. We define peptide detectability as the probability of observing a peptide in a standard sample analyzed by a standard proteomics routine and argue that it is an intrinsic property of the peptide sequence and neighboring regions in the parent protein. To test this hypothesis we first used publicly available data and data from our own synthetic samples in which quantities of model proteins were controlled. We then applied machine learning approaches to demonstrate that peptide detectability can be predicted from its sequence and the neighboring regions in the parent protein with satisfactory accuracy. The utility of this approach for protein quantification is demonstrated by peptides with higher detectability generally being identified at lower concentrations over those with lower detectability in the synthetic protein mixtures. These results establish a direct link between protein concentration and peptide detectability. We show that for each protein there exists a level of peptide detectability above which peptides are detected and below which peptides are not detected in an experiment. We call this level the minimum acceptable detectability for identified peptides (MDIP) which can be calibrated to predict protein concentration. Triplicate analysis of a biological sample showed that these MDIP values are consistent among the three data sets.

Algorithms↗

Probing the structure of the Caulobacter crescentus ribosome with chemical labeling and mass spectrometry.

The ribosomal proteins of Caulobacter crescentus were amidinated before and after disassembly of the organelle and the results analyzed by mass spectrometry. Comparison with structural information from previous X-ray crystal studies of other bacterial ribosomes provides insight about the C. crescentus ribosome. In total, 47 of the 54 proteins present in the ribosome of C. crescentus were detected after labeling. The extent of derivatization for each protein is strongly dependent on the solvent accessibility of its target residues. Proteins of the ribosome stalk, which are known to be largely solvent-accessible, were labeled quite extensively. In striking contrast, other proteins that are known to be highly shielded in their subunits were labeled at very few of their potential sites. Furthermore, evidence that protein L12 binds to the ribosome via its N-terminal domain is consistent with previous findings.

Bacterial Proteins↗

Probing protein tertiary structure with amidination.

A chemical derivatization method, amidination, that has recently been effectively employed in peptide mass spectrometry experiments is used to covalently modify lysines in several standard proteins. Protein and peptide mass spectra identify sites at which the reaction does or does not occur. This is therefore a rapid approach to elucidate solvent-accessible regions of folded proteins.

Amination↗

Peptide de novo sequencing facilitated by a dual-labeling strategy.

A novel peptide derivatization strategy based on guanidination and amidination is presented. Mass-coded labels help distinguish N- and C-terminal fragment ions produced by collision-induced dissociation and are of general utility since peptide N-termini are coded. The amidine labels also promote specific fragmentation pathways that elucidate N-terminal residues and provide valuable internal calibrants. This strategy is demonstrated with the tryptic peptides of several model proteins, including two that are phosphorylated. Additionally, interpreted peptide sequences are matched against a database of over 80,000 proteins to assess the selectivity of this sequencing approach.

Amino Acid Sequence↗

Deamidation as a consequence of beta-elimination of phosphopeptides.

Beta-elimination procedures often precede mass spectrometric analyses of phosphorylated peptides. Unfortunately, the commonly employed reaction conditions facilitate the deamidation of amide-containing residues. In addition to being 1 Da heavier than their amide counterparts, the newly created acidic residues greatly influence peptide tandem mass spectra. The effects of deamidation are investigated for five different amide-containing synthetic peptides exposed to beta-elimination conditions. MALDI-generated ions are analyzed with a tandem TOF mass analyzer. Methodologies for estimating the degree of deamidation from peptide mass spectra are presented, the influence that adjacent residues exert on the rate of deamidation is catalogued, and the impact that deamidation can have on peptide tandem mass spectra is demonstrated. The complications this side reaction can cause for automated data interpretation are also noted.

Amides↗

Effects of tryptic peptide esterification in MALDI mass spectrometry.

The effect of esterification on MALDI ion yield is investigated by using alcohols having different aliphatic chain lengths. For peptides whose ionization yields increase with derivatization, more hydrophobic alcohols tend to yield greater peak enhancements. The completeness of the reaction increases from propanol to methanol. Undesired solvolysis of the amide group in the side chain of Asn or Gln leads to unexpected ester products. Ethanol is suggested as the optimal alcohol for esterification in proteomics experiments since it yields almost complete esterification without substantial solvolysis. Ethanol esterification was employed to facilitate the identification of gel-separated proteins.

Alcohols↗

Denaturation of metalloproteins with EDTA to facilitate enzymatic digestion and mass fingerprinting.

Metal ions bound to a protein often stabilize tertiary and/or quaternary structure. Consequently, the digestion of metalloproteins that precedes analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry is frequently incomplete. It is demonstrated that ethylenediaminetetraacetic acid (EDTA) successfully destabilizes metalloprotein structure and thereby facilitates tryptic digestion and protein identification.

Animals↗

Peptide photodissociation at 157 nm in a linear ion trap mass spectrometer.

The photodissociation by 157 nm light of singly- and doubly-charged peptide ions containing C- or N-terminal arginine residues was studied in a linear ion trap mass spectrometer. Singly-charged peptides yielded primarily x- and a-type ions, depending on the location of the arginine residue, along with some related side-chain fragments. These results are consistent with our previous work using a tandem time-of-flight (TOF) instrument with a vacuum matrix-assisted laser desorption/ionization (MALDI) source. Thus, the different internal energies of precursor ions in the two experiments seem to have little effect on their photofragmentation. For doubly-charged peptides, the dominant fragments observed in both photodissociation and collisionally induced dissociation (CID) experiments are b- and y-type ions. Preliminary experiments demonstrating fragmentation of multiply-charged ubiquitin ions by 157 nm photodissociation are also presented.

Animals↗

Fragmentation of oligosaccharide ions with 157 nm vacuum ultraviolet light.

The 157 nm photofragmentation of native and derivatized oligosaccharides was studied in a linear ion trap and in a home-built matrix-assisted laser desorption/ionization (MALDI) tandem time-of-flight (TOF/TOF) mass spectrometer, and the results were compared with collision-induced dissociation (CID) experiments. Photodissociation produces product ions corresponding to high-energy fragmentation pathways; for cation-derivatized oligosaccharides, it yields strong cross-ring fragment ions and provides better sequence coverage than low- and high-energy CID experiments. On the other hand, for native oligosaccharides, CID yielded somewhat better sequence coverage than photodissociation. The ion trap enables CID hybrid MS3 experiments on the high-energy fragment ions obtained from photodissociation.

Carbohydrate Sequence↗

Pathways of peptide ion fragmentation induced by vacuum ultraviolet light.

One Hundred Fifty-Seven nm photodissociation of singly protonated peptides generates unusual distributions of fragment ions. When the charge is localized at the C-terminus of the peptide, spectra are dominated by x-, v-, and w-type fragments. When it is sequestered at the N-terminus, a- and d-type ions are overwhelmingly abundant. Evidence is presented suggesting that the fragmentation occurs via photolytic radical cleavage of the peptide backbone at the bond between the alpha- and carbonyl-carbons followed by radical elimination to form the observed daughter ions.

Arginine↗

Photoimmobilization of proteins for affinity capture combined with MALDI TOF MS analysis.

Affinity capture surfaces can be prepared in a number of ways. A method of obtaining such surfaces through UV-activated immobilization of binding proteins using a benzophenone derivative is reported. Photoimmobilized protein G was used to selectively capture and preconcentrate bovine IgG from a mixture with BSA, and the affinity of photoattached concanavalin A toward ovalbumin was compared with that of commercially available concanavalin A on agarose beads. The results of the capture after tryptic digestion were analyzed by MALDI TOF MS. Immobilized trypsin was also prepared through photoimmobilization and later used to digest hemoglobin. Immobilized enzyme digestion resulted in more partial cleavages than solution-phase digestion. More methionine and tryptophan oxidation was also observed. Photoimmobilization was shown to be a quick and easy way of immobilizing ligands on surfaces.

Amino Acid Sequence↗

Microdeposition device interfacing capillary electrochromatography and microcolumn liquid chromatography with matrix-assisted laser desorption/ionization mass spectrometry.

A sample deposition device has been constructed and optimized for interfacing CEC and capillary LC columns to MALDI mass spectrometry. For CEC analysis, the device is composed of an inlet buffer reservoir and an outlet buffer reservoir connected to a matrix reservoir through a connection sleeve. The matrix reservoir is connected to a deposition capillary via another connection sleeve. CEC eluent is transported to the matrix reservoir via a capillary that is connected to the deposition capillary by the connection sleeve inside the matrix reservoir. This connection sleeve also acts as a mixing chamber, allowing the CEC eluent to be mixed with matrix prior to deposition. Complex glycan mixtures can be separated by CEC using hydrophilic-phase monolithic columns, with capillary eluent being deposited on a standard MALDI plate along with a suitable matrix solution. Thousands of discrete, highly homogeneous dots can be generated for a subsequent mass spectrometric analysis. With minor modifications, this device is also applicable to capillary LC of peptides using gradient elution. In this configuration, the outlet of the LC column is connected to a deposition capillary inside a matrix reservoir through a connection sleeve that allows mixing of the LC effluent with an appropriate matrix. The device has been evaluated with the tryptic digests of proteins.

Chromatography, Liquid↗