PubMed Health⌕ Search

Biomedical subjects

James W Schumm

Publications and source records attributed to James W Schumm.

5 recordsLinked to original sources

Buccal DNA samples for DNA typing: new collection and processing methods.

With the recent expansion of DNA database laws in many states, there is a critical need for the rapid and simple collection of DNA samples and streamlined processing for downstream applications. The Buccal DNA Collector was developed to address the need for a reliable, practical alternative to blood collection that is compatible with high-throughput operations. The collection area consists of filter paper that is placed against the inside of the cheek, and the sample is taken by swiping the cheek several times while pulling the device out of the mouth. Using this method, DNA profiles have been obtained from samples stored for 2 years at room temperature. Cells are collected on all regions of the filter paper with the maximum DNA recovery from the tip. The processing of DNA for DNA typing is accomplished with BodeElute, a new product that prepares DNA for amplification in a single 30-min heating step. Extracted DNA samples were successfully amplified with four commonly used multiplex short tandem repeat (STR) amplification kits. These products provide simplified approaches for collecting and processing buccal cell samples.

DNA↗

Validation and implementation of the PowerPlex 16 BIO System STR multiplex for forensic casework.

The PowerPlex 16 BIO multiplex short tandem repeat (STR) system contains the 13 CODIS loci (FGA, TPOX, D8S1179, vWA, D18S51, D21S11, TH01, D3S1358, CSF1PO, D16S539, D7S820, D13S317, and DS5S818), plus two pentanucleotide repeat loci (Penta D and Penta E) and the sex-identifying locus. Amelogenin. The PowerPlex 16 BIO System is optimized for use with the Hitachi FMBIO gel imaging systems. A consortium of seven independent laboratories collaborated to perform the studies defined by the FBI standards for performing a developmental validation, including the evaluation of sample concordance, percent stutter determination, nonprobative casework, precision, sensitivity, mixture determination, effect of substrates, the impact of environmental insults, and species specificity. All samples tested for concordance were consistent except for one sample from the Virginia Division of Forensic Science database that displayed discordance at D13S317, a locus whose primer sequence was altered. Stutter values were comparable to those of other STR multiplex systems, the precision was comparable to other multiplexes analyzed by gel electrophoresis, the DNA profiles were unchanged by the substrate upon which the blood samples were placed, and the nonprobative casework samples re-typed for the PowerPlex 16 BIO System were consistent with previous typing results. When greater than 0.125 ng of DNA was placed into the PowerPlex 16 BIO System amplification reaction, a full profile was generated by all laboratories. The mixture study results were comparable to those reported for other multiplex systems, the environmental study demonstrated a loss of larger molecular weight loci when samples were incubated at elevated temperatures for a prolonged period of time, and the only notable cross species hybridization was observed with primate DNA samples. This extensive validation work performed demonstrates that the PowerPlex 16 BIO System provides STR data of a quality comparable with other PowerPlex STR multiplex kits as well as other widely used STR multiplexes and is thus suitable for evidentiary casework analysis as well as database sample profiling.

Alleles↗

Development, characterization, and validation of a sensitive primate-specific quantification assay for forensic analysis.

Accurate human-specific DNA quantification is essential for forensic casework analysis. In this work, we describe a microplate-based quantification assay that utilizes the PCR amplification of human-specific TH01 primers. This method enables the reliable quantification of human DNA samples from 0.2 to 40 ng, even in mixtures with nonhuman DNA. Analysis of samples can be semi-automated using 96-well microplates and a spreadsheet-based concentration calculator for high-throughput demands. We have used this quantification method with more than 15,000 forensic samples.

Animals↗

Detection of a primer-binding site polymorphism for the STR locus D16S539 using the Powerplex 1.1 system and validation of a degenerate primer to correct for the polymorphism.

Quality assurance samples submitted from the NCSBI as part of a contract with TBTG to outsource DNA Database samples showed unexpected discrepancies for the locus D16S539 when all other loci yielded identical results. Discrepancies observed included allele drop out and an imbalance in sister alleles with samples returned from TBTG. This led to a comprehensive review of the technical procedures used between the two laboratories to determine the cause of the discrepancies noted for the locus D16S539, since both laboratories were using the PowerPlex 1.1 typing kit from the Promega Corporation. The NCSBI and the TBTG utilize different extraction methods (organic extraction vs. FTA) and amplification conditions (AmpliTaq vs AmpliTaq Gold), respectively, so the exact cause of discrepancy observed was not immediately apparent. Experiments at the NCSBI associated the observed allele drop out and the imbalance of the sister alleles with the use of AmpliTaq Gold and a hot start procedure. Sequencing data revealed that a point mutation resides on the D16S539 primer-binding site that reaches polymorphic levels in African-American populations. This led to the development of a degenerate primer by the Promega Corporation to detect "missing" alleles when AmpliTaq Gold is used. The degenerate primer was then thoroughly tested to show its efficacy in detecting the "true" D16S539 profile when used.

Allelic Imbalance↗

Characterization and validation studies of powerPlex 2.1, a nine-locus short tandem repeat (STR) multiplex system and penta D monoplex.

In order to increase the power of discrimination for human identification purposes, a nine-locus short tandem repeat (STR) multiplex, the GenePrint PowerPlex 2.1 system (PowerPlex 2.1) developed by Promega Corporation and a separate pentanucleotide-repeat locus, Penta D, were tested. This megaplex system includes the highly polymorphic loci FGA, TPOX, D8S1179, vWA, Penta E, D18S51, D21S11, TH01, and D3S1358 and may be used in combination with the eight-locus STR multiplex, the GenePrint PowerPlex 1.1 system (PowerPlex 1.1) that has been previously developed. Three of the loci, TPOX, TH01 and vWA, have been included in both systems for quality control purposes. As with PowerPlex 1.1, PowerPlex 2.1 is also based on a two-color detection of fluorescent-labeled DNA products amplified by polymerase chain reaction (PCR) and provides a valuable tool for accurate and rapid allele determination. The primer sequences used in the PowerPlex 2.1/Penta D system are also presented in this report. To meet the "Quality Assurance Standards for Forensic DNA Testing Laboratories" (FBI), we tested the efficiency and reproducibility of the PowerPlex 2.1/PentaD system by several validation studies that were conducted as a joint project among seven laboratories. Validation tests included concordance studies, sensitivity, and species specificity determination, as well as performance in forensic and environmentally impacted samples. The results produced from these tests demonstrated the consistency and reliability of the PowerPlex 2.1/Penta D system.

Animals↗