PubMed Health⌕ Search

Biomedical subjects

Jana M Swenson

Publications and source records attributed to Jana M Swenson.

7 recordsLinked to original sources

Multicenter studies of tigecycline disk diffusion susceptibility results for Acinetobacter spp.

Acinetobacter sp. isolates having multidrug resistance (MDR) patterns have become common in many medical centers worldwide, limiting therapeutic options. A five-center study tested 103 contemporary clinical Acinetobacter spp., including MDR strains, by reference broth microdilution and disk diffusion (15-mug disk content) methods against tigecycline. Applying U.S. Food and Drug Administration tigecycline breakpoint criteria for Enterobacteriaceae (susceptibility at < or =2 microg/ml [< or =1 microg/ml by the European Committee on Antimicrobial Susceptibility Testing]; disk diffusion breakpoints at > or =19 mm and < or =14 mm) to Acinetobacter spp. led to an unacceptable error rate (23.3%). However, an adjustment of tigecycline disk diffusion breakpoints (susceptible/resistant) to > or =16/ < or =12 mm reduced intermethod errors to an acceptable level (only 9.7%, all minor).

Acinetobacter↗

Quality control guidelines for testing gram-negative control strains with polymyxin B and colistin (polymyxin E) by standardized methods.

An eight-laboratory study addressed the urgent need for quality control (QC) ranges for susceptibility determination when testing colistin (polymyxin E) and polymyxin B, two polycationic peptide antimicrobial agents, against multidrug-resistant gram-negative bacilli. For Escherichia coli ATCC 25922l, the QC ranges were as follows: for colistin, 0.25 to 1 microg/ml (11 to 17 mm), and for polymyxin B, 0.25 to 2 microg/ml (13 to 19 mm). For Pseudomonas aeruginosa ATCC 27853, the QC ranges were as follows: for colistin, 0.25 to 2 microg/ml (11 to 17 mm), and for polymyxin B, 0.25 to 2 mug/ml (14 to 18 mm). More than 97% of all reported QC results were within these proposed ranges.

Anti-Bacterial Agents↗

Results of disk diffusion testing with cefoxitin correlate with presence of mecA in Staphylococcus spp.

The cefoxitin disk diffusion (DD) test for predicting mecA-mediated oxacillin resistance in staphylococci was assessed during a three-phase study. In phase 1, one laboratory tested 62 and 53 strains of Staphylococcus aureus and coagulase-negative staphylococci (CoNS), respectively. These data were used to choose the provisional cefoxitin DD breakpoints (resistant/susceptible) of < or =19 mm/> or =20 mm for S. aureus and < or =24 mm/> or =25 mm for CoNS for the next phase of testing. In phase 2, 10 laboratories each tested approximately 40 in-house strains of staphylococci (half of which were S. aureus) using Mueller-Hinton agar from different manufacturers. In this phase, the sensitivity and specificity, respectively, of the cefoxitin disk test were 98 and 100% for S. aureus and 99 and 96% for CoNS. The cefoxitin DD test performed equivalently to oxacillin broth microdilution (BMD) and to oxacillin DD tests among S. aureus and mecA-positive CoNS strains but gave better results than oxacillin BMD or oxacillin DD for mecA-negative strains of CoNS. The cefoxitin DD test also was much easier to read and did not require the use of transmitted light for detection of resistance. Based on data from the first two phases, the Clinical and Laboratory Standards Institute (CLSI; formerly NCCLS) adopted the use of the cefoxitin DD test for predicting mecA-mediated oxacillin resistance in staphylococci and revised Table 2C in CLSI document M100-S14 to reflect the change. In the third phase, an additional 61 challenge strains of CoNS for which the oxacillin MICs were 0.5 to 2 microg/ml were tested in a single laboratory to determine the effectiveness of the cefoxitin DD test for this group of borderline-resistant isolates. These data were used to refine the description of the test in CLSI document M100-S15. The cefoxitin DD test is preferred over the oxacillin DD test for predicting mecA-mediated oxacillin resistance in S. aureus and CoNS.

Bacterial Proteins↗

Antimicrobial susceptibility testing of Acinetobacter spp. by NCCLS broth microdilution and disk diffusion methods.

Although both broth microdilution (BMD) and disk diffusion (DD) are listed by NCCLS as acceptable methods for testing Acinetobacter spp. for antimicrobial susceptibility, few studies have compared the results generated by the two methods. We tested 196 isolates of Acinetobacter spp. from nine U.S. hospitals and from the Centers for Disease Control culture collection by using BMD and DD and clinically appropriate antimicrobial agents. Categorical results for amikacin, ciprofloxacin, gatifloxacin, gentamicin, imipenem, levofloxacin, meropenem, tobramycin, and trimethoprim-sulfamethoxazole were comparable for the two methods: there was only one very major (VM) error, with tobramycin, and only one major (M) error, with meropenem, when DD results were compared with BMD results. However, VM errors were frequent with the beta-lactams and beta-lactam-beta-lactam inhibitor combinations, while M errors were often observed with tetracyclines. For BMD, tests frequently exhibited subtle growth patterns that were difficult to interpret, especially for beta-lactams. If subtle growth (i.e., granular, small button, or "starry" growth) was considered positive, error rates between BMD and DD were unacceptably high for ampicillin-sulbactam (VM error, 9.8%; minor [m] error, 16.1%), piperacillin (VM error, 5.7%; m error, 13.5%), piperacillin-tazobactam (VM error, 9.3%; m error, 12.9%), ceftazidime (VM error, 6.2%; m error, 11.4%), cefepime (VM error, 6.2%; m error, 13.0%), cefotaxime (m error, 21.2%), ceftriaxone (m error, 23.3%), tetracycline (M error, 11.4%; m error, 32.1%), and doxycycline (M error, 2.6%). When subtle growth patterns were ignored, the agreement still did not achieve acceptable levels. To determine if the problems with BMD testing occurred in other laboratories, we sent frozen BMD panels containing beta-lactam drugs and nine isolates to six labs with experience in performing BMD and DD. Among these laboratories, cefepime MICs ranged from < or =8 to > or =32 microg/ml for four of the nine strains, confirming the problem in interpreting BMD results. Discrepancies between the categorical interpretations of BMD and DD tests were noted primarily with cefepime and piperacillin, for which the BMD results were typically more resistant. Clinical laboratories should be aware of these discrepancies. At present, there are no data to indicate which method provides more clinically relevant information.

Acinetobacter↗

Antimicrobial susceptibility testing of carbapenems: multicenter validity testing and accuracy levels of five antimicrobial test methods for detecting resistance in Enterobacteriaceae and Pseudomonas aeruginosa isolates.

From January 1996 to May 1999, Project ICARE (Intensive Care Antimicrobial Resistance Epidemiology) received 448 nonduplicate clinical isolates of Enterobacteriaceae and Pseudomonas aeruginosa that were reported to be imipenem intermediate or resistant. However, broth microdilution (BMD) confirmatory testing at the Project ICARE central laboratory confirmed this result in only 11 of 123 (8.9%) Enterobacteriaceae isolates and 241 of 325 (74.2%) P. aeruginosa isolates. To investigate this overdetection of imipenem resistance, we tested 204 selected isolates from the Project ICARE collection plus five imipenem-resistant challenge strains at the Centers for Disease Control and Prevention against imipenem and meropenem by agar dilution, disk diffusion, Etest (AB BIODISK North America, Inc., Piscataway, N.J.), two MicroScan WalkAway conventional panels (Neg MIC Plus 3 and Neg Urine Combo 3) (Dade MicroScan, Inc., West Sacramento, Calif.), and two Vitek cards (GNS-116 containing meropenem and GNS-F7 containing imipenem) (bioMérieux Vitek, Inc., Durham, N.C.). The results of each test method were compared to the results of BMD testing using in-house-prepared panels. Seven imipenem-resistant and five meropenem-resistant isolates of Enterobacteriaceae and 43 imipenem-resistant and 21 meropenem-resistant isolates of P. aeruginosa were identified by BMD. For Enterobacteriaceae, the imipenem and meropenem test methods produced low numbers of very major and major errors. All test systems in the study produced low numbers of very major and major errors when P. aeruginosa was tested against imipenem and meropenem, except for Vitek testing (major error rate for imipenem, 20%). Further testing conducted in 11 of the participating ICARE hospital laboratories failed to pinpoint the factors responsible for the initial overdetection of imipenem resistance. However, this study demonstrated that carbapenem testing difficulties do exist and that laboratories should consider using a second, independent antimicrobial susceptibility testing method to validate carbapenem-intermediate and -resistant results.

Carbapenems↗

In vitro activity of a new cephalosporin, RWJ-54428, against streptococci, enterococci and staphylococci, including glycopeptide-intermediate Staphylococcus aureus.

The need for new antimicrobial agents with activity against Gram-positive organisms has become increasingly important because of emerging resistance. We compared the activity of a new b-lactam antimicrobial agent, RWJ-54428 (MC-02 479), with representatives of other classes of antimicrobial agents against 76 Staphylococcus aureus (including four glycopeptide- intermediate strains), 50 coagulase-negative staphylococci, 20 Enterococcus faecalis, 20 Enterococcus faecium, 10 Enterococcus gallinarum/Enterococcus casseliflavus, 54 Streptococcus pneumoniae and 22 viridans streptococcal isolates. The MIC(90) of RWJ-54,428 was < or = 2 mg/L for all groups of bacteria tested except E. faecium. The activity against four strains of glycopeptide-intermediate S. aureus was similar to that for other methicillin-resistant S. aureus isolates (range 0.5-2.0 mg/L).

Acetamides↗