MicroSPE-nanoLC-ESI-MS/MS using 10-microm-i.d. silica-based monolithic columns for proteomics.

Silica-based monolithic capillary columns (25 cm x 10 microm i.d.) with integrated nanoESI emitters have been developed to provide high-quality and robust microSPE-nanoLC-ESI-MS analyses. The integrated nanoESI emitter adds no dead volume to the LC separation, allowing stable electrospray operation at flow rates of approximately 10 nL/min. In an initial application with a linear ion trap MS, we identified 5510 unique peptides that covered 1443 distinct Shewanella oneidensis proteins from a 300-ng tryptic digest sample in a single 4-h LC-MS/MS analysis. The use of an integrated monolithic ESI emitter provided enhanced resistance to clogging and provided good run-to-run reproducibility.

Chromatography, Liquid↗

Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry.

We have developed a new procedure for fabricating fused-silica emitters for electrospray ionization-mass spectrometry (ESI-MS) in which the end of a bare fused-silica capillary is immersed into aqueous hydrofluoric acid, and water is pumped through the capillary to prevent etching of the interior. Surface tension causes the etchant to climb the capillary exterior, and the etch rate in the resulting meniscus decreases as a function of distance from the bulk solution. Etching continues until the silica touching the hydrofluoric acid reservoir is completely removed, essentially stopping the etch process. The resulting emitters have no internal taper, making them much less prone to clogging compared to, e.g., pulled emitters. The high aspect ratios and extremely thin walls at the orifice facilitate very low flow rate operation; stable ESI-MS signals were obtained for model analytes from 5-microm-diameter emitters at a flow rate of 5 nL/min with a high degree of interemitter reproducibility. In extensive evaluation, the etched emitters were found to enable approximately four times as many LC-MS analyses of proteomic samples before failing compared with conventional pulled emitters. The fabrication procedure was also employed to taper the ends of polymer monolith-containing silica capillaries for use as ESI emitters. In contrast to previous work, the monolithic material protrudes beyond the fused-silica capillaries, improving the monolith-assisted electrospray process.

Hydrofluoric Acid↗

Theoretical and experimental evaluation of the low m/z transmission of an electrodynamic ion funnel.

The transmission of ions at low m/z can often be either necessary for an application or problematic (e.g., when large numbers of low m/z ions consume a large fraction of an ion trap's capacity). The low m/z ion transmission limit of an electrodynamic ion funnel has been characterized using both experimental and theoretical approaches. A theoretical model is developed based on a series of infinite wire conductors that represent the ring electrodes of the ion funnel. Mathematical relationships for both low and high m/z cutoffs of the idealized two-dimensional system are derived. The low m/z cutoff is also evaluated through a series of experiments that show it is influenced by both the RF frequency and the DC electric field gradient. However, unlike multipole ion guides, there is no marked dependence of the low m/z cutoff on the RF amplitude, in agreement with theoretical results. With this new understanding, ion funnels can be designed and configured to better match the m/z range requirements for various applications.

Electrochemistry↗

Variable low-mass filtering using an electrodynamic ion funnel.

An adjustable low-mass filter has been developed for an electrospray ionization (ESI) source to block ions associated with unwanted background species from entering the mass spectrometer. The low-mass filter is made by using an adjustable potential energy barrier from the conductance-limiting plate of an electrodynamic ion funnel, which prohibits species with higher ion mobilities from exiting the ESI source. We show that this arrangement provides a linear voltage adjustment for low-mass filtering from m/z 0 to 500. Mass filtering above m/z 500 is also performed; however, higher-mass species are attenuated. The mass filter was tested with a liquid chromatography/mass spectrometry (LC/MS) analysis of a bovine serum albumin (BSA) tryptic digest and resulted in the ability to block low-mass, background species, which accounted for 40-70% of the total ion current immediately behind the ESI source during peak elution and detection.

Animals↗

Automatic gain control in mass spectrometry using a jet disrupter electrode in an electrodynamic ion funnel.

We report on the use of a jet disrupter electrode in an electrodynamic ion funnel as an electronic valve to regulate the intensity of the ion beam transmitted through the interface of a mass spectrometer in order to perform automatic gain control (AGC). The ion flux is determined by either directly detecting the ion current on the conductance limiting orifice of the ion funnel or using a short mass spectrometry acquisition. Based upon the ion flux intensity, the voltage of the jet disrupter is adjusted to alter the transmission efficiency of the ion funnel to provide a desired ion population to the mass analyzer. Ion beam regulation by an ion funnel is shown to provide control to within a few percent of a targeted ion intensity or abundance. The utility of ion funnel AGC was evaluated using a protein tryptic digest analyzed with liquid chromatography Fourier transform ion cyclotron resonance (LC-FTICR) mass spectrometry. The ion population in the ICR cell was accurately controlled to selected levels, which improved data quality and provided better mass measurement accuracy.

Electrodes↗

FTICR mass spectrometry for qualitative and quantitative bioanalyses.

Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is playing an increasing role in the characterization of cellular systems owing to its capabilities for providing higher confidence of identification, increased dynamic range and sensitivity unmatched by other MS platforms. Particularly in proteomics, where global and quantitative approaches are essential, the attributes of FTICR-MS are poised to make significant contributions. Recent advances in the field that have particular importance for proteomic applications include the use of high-performance micro-capillary column separation techniques coupled to FTICR, as well as methods that improve protein identification, sensitivity, dynamic range and throughput.

Animals↗

Charge competition and the linear dynamic range of detection in electrospray ionization mass spectrometry.

An experimental investigation and theoretical analysis are reported on charge competition in electrospray ionization (ESI) and its effects on the linear dynamic range of ESI mass spectrometric (MS) measurements. The experiments confirmed the expected increase of MS sensitivities as the ESI flow rate decreases. However, different compounds show somewhat different mass spectral peak intensities even at the lowest flow rates, at the same concentration and electrospray operating conditions. MS response for each compound solution shows good linearity at lower concentrations and levels off at high concentration, consistent with analyte "saturation" in the ESI process. The extent of charge competition leading to saturation in the ESI process is consistent with the relative magnitude of excess charge in the electrospray compared to the total number of analyte molecules in the solution. This ESI capacity model allows one to predict the sample concentration limits for charge competition and the on-set of ionization suppression effects, as well as the linear dynamic range for ESI-MS. The implications for quantitative MS analysis and possibilities for effectively extending the dynamic range of ESI measurements are discussed.

Caffeine↗

Sample depletion of the matrix-assisted laser desorption process monitored using radionuclide detection.

To investigate analyte consumption during the laser desorption process, matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) is combined with radionuclide detection. Radionuclide detection provides highly sensitive and quantitative information on the amount of radiolabeled analytes in a MALDI MS sample spot. 14C-Labeled cytochrome c is deposited with 2,5-dihydroxybenzoic acid in 10-nL volume spots. By comparing radioactivity levels of the labeled cytochrome c both before and after spectral acquisition, the reduction in labeled analyte molecules on the target allows monitoring of the moles of desorbed sample. Through a depletion study on this sample, the amount of analyte consumed for MALDI time-of-flight spectral acquisition and the average number of molecules desorbed per laser ablation are determined. When [14C]-cytochrome c is no longer detected by MALDI MS, approximately 70% of the original analyte remains in the sample spots. Redissolving the spots produced further desorption, indicating that the analyte before dissolution was in a physical environment that did not facilitate the desorption process. As a technique with a response that does not depend on the environment of the analyte, radionuclide detection allows characterization of mass-limited sampling methods to better understand the MALDI process.

Carbon Radioisotopes↗

Single-neuron analysis using CE combined with MALDI MS and radionuclide detection.

Capillary electrophoresis (CE) has been combined with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) and radionuclide detection to assay mass-limited biological samples. Nanovial sampling techniques enable injections into the CE capillary from 50 to 150-nL volume samples; after the separation, nanoliter fraction collection combines the CE effluent with a MALDI matrix and minimizes sample spreading, thus allowing both MALDI MS and radionuclide detection on the CE fractions. MALDI MS complements the elution time information of CE by providing accurate molecular mass data, and radionuclide detection provides zeptomole limits of detection with quantitative information. While MALDI MS detects all fully processed peptides at sufficient concentration, culturing the neuron in media containing 35S-Met provides selective radionuclide detection of newly synthesized methionine-containing peptides. The analysis and detection of the expected neuropeptides and hormones in a single 40-microm bag cell neuron from Aplysia californica with CE/MALDI MS/radionuclide detection demonstrates the ability of this hyphenated approach to work with chemically complex mass-limited samples.