PubMed Health⌕ Search

Biomedical subjects

Jean Pettersson

Publications and source records attributed to Jean Pettersson.

4 recordsLinked to original sources

On-line electrochemically controlled solid-phase extraction interfaced to electrospray and inductively coupled plasma mass spectrometry.

Electrochemically controlled solid-phase extractions of anions were interfaced on-line to electrospray mass spectrometry (ESI-MS) and inductively coupled plasma mass spectrometry (ICP-MS), using polypyrrole coated electrodes and a thin-layer electrochemical (EC) flow cell. The results indicate that electrochemically controlled solid-phase extraction (EC-SPE) can be used as a versatile potential controlled sample preparation technique for a range of anions and that the properties of the polypyrrole coatings can be modified by altering the electrodeposition conditions. In the present study, the influence of interfering anions (i.e., fluoride and sulfate), and the anion used during the electropolymerisation, on the bromide extraction recovery was investigated for EC-SPE interfaced to ICP-MS. The results of these experiments show that the interference due to the presence of similar concentrations of sulfate can be reduced when using a polypyrrole coating electropolymerised in the presence of bromide ions. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) measurements were also used to study the morphology of the coatings, as well as the variations in the film thickness within the coatings. The effect of different desorption techniques on the bromide preconcentration factor in the ICP-MS on-line flow system was also examined. Stopped-flow desorption was found to give rise to significantly increased preconcentration factors in comparison with desorptions in flowing solutions. While the desorption efficiency depends on the type of desorption electrolyte (the electrolyte in which the desorption takes place), due to the competing influx of cations, the influence of the pH on the switching charge of the polypyrrole coating was found to be small, at constant ionic strength. To study the applicability of the EC-SPE technique with respect to real samples, investigations were also made with tap water samples spiked with different bromide concentrations. The results of these experiments, which were carried out using a modified thin-layer EC flow cell allowing in situ polymerisation of polypyrrole yielding a polymer plug covering the cross section of the channel, demonstrate that 3 microM concentrations of bromide could be detected in the tap water sample. This demonstrates that the extraction technique allows extractions of low concentrations of ions in the presence of significantly higher concentrations of other similar ions. The fact that the extraction and desorption steps are electrochemically controlled makes EC-SPE particularly well suited for inclusion in miniaturised lab-on-a-chip systems.

Bromides↗

Fingerprinting metal-containing biomolecules after reductive displacement of iron by gallium and subsequent column-switched LC-ICPMS analysis applied on siderophores.

Column-switching liquid chromatography followed by low-resolution ICPMS was evaluated as a tool for speciation analysis of metal-containing biomolecules. The strategy was applied on siderophores, strong iron chelators of low molecular weight (M(w) < 1500). Prior to the LC-ICPMS analysis, reductive displacement of iron by gallium was performed using ascorbate as the reducing agent to increase the sensitivity. Different experimental conditions during the exchange reaction were tested using ferrichrysin and ferrichrome for evaluation. A reaction time of 30 min and a pH of 3.9 gave an exchange yield of 27 and 83% for ferrichrysin and ferrichrome, respectively. A gradient elution profile was also developed to separate gallium-chelated siderophores on a PGC column. Detection limits for standard solutions of ferrichrysin and ferrichrome in the low-nanomolar range were obtained by monitoring the gallium-69 isotope. The combined use of LC-ICPMS and LC-ESI-MS/MS was also evaluated as a tool to identify unknown metal complexes, here siderophores, in field soil solution samples.

Ascorbic Acid↗

Determination of boron-containing compounds in urine and blood plasma from boron neutron capture therapy patients. The importance of using coupled techniques.

The necessity of using coupled techniques to analyze samples from boron neutron capture therapy (BNCT) patients prior to element-specific detection has been demonstrated. BNCT patients were infused with p-boronophenylalanine (BPA)-fructose complex before the therapy started. Urine and blood plasma samples were collected at different times after the start of the BPA administration and were run on a porous graphitic carbon column coupled on-line to an inductively coupled plasma-atomic emission spectrometer (ICP-AES) and an ICP time-of-flight mass spectrometer (TOF-MS). In addition to BPA, a possible metabolite to BPA and some minor boron-containing compounds, eluting close to the front, were also found in the urine and plasma samples. Because only the total concentration of boron has been measured so far in earlier studies, the suspected metabolite could not be detected, and this is the first report indicating its presence in urine and plasma of BNCT patients. The abundance of 10B in urine was about the same for BPA and its possible metabolite (98-99%). The ratio between the possible metabolite and BPA was found to differ in the urine from different patients. Most of the patients had a metabolite concentration of approximately 10 mol % of the BPA content in their urine 5-11 h after the start of the BPA administration. This ratio increased to between 30 and 80% when 24 h had passed. The ratio of metabolite to BPA was found to be lower in the plasma than in the urine samples at comparable time after the start of BPA infusion. Preliminary results from micro-LC-electrospray ionization (ESI)-MS/MS measurements on four urine samples indicate that the metabolite has a higher mass than BPA.

Boron Compounds↗

Electrochemical solid-phase microextraction of anions and cations using polypyrrole coatings and an integrated three-electrode device.

A method for the extraction, transfer and desorption of anions and cations under controlled potential conditions employing a new integrated three-electrode device is described. The device, containing working, reference and counter electrodes, was prepared from tubes that could be moved vertically with respect to each other. In this way, a small amount of solvent, held by capillary force, remained between the electrodes when the device was lifted out of a solution after an extraction. This design allowed the potential control to be maintained at all times. With the new integrated device, it was possible to perform potential controlled desorption into vials containing as little as 200 microl of solution. The required ion exchange capacity was obtained by electrodeposition of a polypyrrole coating on the surface of the glassy carbon working electrode. Solid-phase microextractions of several cations or anions were performed simultaneously under potentiostatic control by doping the polypyrrole coating with different anions such as perchlorate and p-toluenesulfonate. The efficiency of the extractions, which could be altered by varying the potential of the working electrode, could be increased by 150 to 200% compared to extractions using normal solid-phase microextraction conditions under open circuit conditions. A constant potential of +1.0 V and -0.5 V with respect to the silver pseudo reference electrode, was found to be well-suited for the extraction of samples containing ppm concentrations of anions (chloride, nitrite, bromide, nitrate, sulfate and phosphate) and cations (cadmium, cobalt and zinc), respectively.

Journal Article↗