On-line electrochemically controlled solid-phase extraction interfaced to electrospray and inductively coupled plasma mass spectrometry.

Abstract

Electrochemically controlled solid-phase extractions of anions were interfaced on-line to electrospray mass spectrometry (ESI-MS) and inductively coupled plasma mass spectrometry (ICP-MS), using polypyrrole coated electrodes and a thin-layer electrochemical (EC) flow cell. The results indicate that electrochemically controlled solid-phase extraction (EC-SPE) can be used as a versatile potential controlled sample preparation technique for a range of anions and that the properties of the polypyrrole coatings can be modified by altering the electrodeposition conditions. In the present study, the influence of interfering anions (i.e., fluoride and sulfate), and the anion used during the electropolymerisation, on the bromide extraction recovery was investigated for EC-SPE interfaced to ICP-MS. The results of these experiments show that the interference due to the presence of similar concentrations of sulfate can be reduced when using a polypyrrole coating electropolymerised in the presence of bromide ions. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) measurements were also used to study the morphology of the coatings, as well as the variations in the film thickness within the coatings. The effect of different desorption techniques on the bromide preconcentration factor in the ICP-MS on-line flow system was also examined. Stopped-flow desorption was found to give rise to significantly increased preconcentration factors in comparison with desorptions in flowing solutions. While the desorption efficiency depends on the type of desorption electrolyte (the electrolyte in which the desorption takes place), due to the competing influx of cations, the influence of the pH on the switching charge of the polypyrrole coating was found to be small, at constant ionic strength. To study the applicability of the EC-SPE technique with respect to real samples, investigations were also made with tap water samples spiked with different bromide concentrations. The results of these experiments, which were carried out using a modified thin-layer EC flow cell allowing in situ polymerisation of polypyrrole yielding a polymer plug covering the cross section of the channel, demonstrate that 3 microM concentrations of bromide could be detected in the tap water sample. This demonstrates that the extraction technique allows extractions of low concentrations of ions in the presence of significantly higher concentrations of other similar ions. The fact that the extraction and desorption steps are electrochemically controlled makes EC-SPE particularly well suited for inclusion in miniaturised lab-on-a-chip systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gustav Liljegren, Niklas Forsgard, Camilla Zettersten, Jean Pettersson, Malin Svedberg, Merja Herranen, Leif Nyholm. 2005-08-31. On-line electrochemically controlled solid-phase extraction interfaced to electrospray and inductively coupled plasma mass spectrometry.. https://doi.org/10.1039/b508388e

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Eu-doped CsBr phosphor as a new optically-stimulable phosphor material for medical X-ray imaging sensor.

CsBr phosphor ceramics doped with different luminescence centres such as In2O3, Eu2O3, EuCl3, SmCl3, TbCl3, GdCl3 or NdCl3 as the candidate for a new optically-stimulable phosphor for medical X-ray imaging sensor were prepared using a conventional ceramic fabrication process. It was found that X-ray-irradiated Eu-doped CsBr (CsBr:Eu) exhibited intense optically stimulated luminescence (OSL). The peak wavelength of the OSL emission and stimulation spectra of CsBr:Eu phosphor ceramic sample were 450 and 690 nm, respectively. The dependence of OSL properties on the conditions of preparation of phosphor ceramic samples, such as Eu concentration, sintering temperature and sintering time, were studied. The optimum preparation conditions were also studied. It was found that the OSL intensity of CsBr:Eu phosphor ceramics fabricated under optimum preparation conditions is higher than that of commercially available imaging plates using BaFBr:Eu.

Bromides↗

Surfactant-assisted hollowing of Cu nanoparticles involving halide-induced corrosion-oxidation processes.

We have demonstrated a simple fabrication of hollow nanoparticles by halide-induced corrosion oxidation with the aid of surfactants. Cuprous oxide Cu2O nanoshells can be generated by simply mixing Cu nanoparticles with alkyltrimethylammonium halides at 55 degrees C for 16 min. The hollowing mechanism proposed is that absorption of surfactants onto the Cu surface facilitates the formation of the void interior through an oxidative etching process. Upon extending the reaction up to 4 h, fragmentation, oxidation, and self-assembly were observed and the CuO ellipsoidal structures were formed. The headgroup lengths of the surfactants influenced the degree of CuO ellipsoidal formation, whereby longer surfactants favored the generation of ellipsoids. Optical absorption measured by UV-visible spectroscopy was used to monitor both oxidation courses of Cu-->Cu2O and Cu2O-->CuO and to determine the band-gap energies as 2.4 eV for Cu2O nanoshells and 1.89 eV for CuO ellipsoids. For the contact-angle measurements, the wettability changed from hydrophilicity (18 degrees) to hydrophobicity (140 degrees) as the Cu2O nanoshells shifted to CuO ellipsoids.

Bromides↗

The effect of ionic strength on the UV-vis spectrum of congo red in aqueous solution.

The major peak near 498 nm in the ultraviolet-visible spectrum of congo red in aqueous solution shifts toward the blue while the molar absorptivity of this peak decreases predictably with increasing ionic strength. The shift was observed for solutions in which ionic strength was varied from 0.0 to 1.8M using the uni-univalent ionic compounds, NaCl, NaClO(4), KNO(3) and KBr separately. A plot of the log of the absorbance at the peak versus ionic strength was linear as well as a plot of the log of the wavelength of the major peak (shifted from 498 nm) versus the ionic strength. The slopes of each of these plots were somewhat different depending on the ionic compound.

Bromides↗