PubMed Health⌕ Search

Biomedical subjects

Jens Gysler

Publications and source records attributed to Jens Gysler.

3 recordsLinked to original sources

Peak shape improvement of basic analytes in capillary liquid chromatography.

The analysis of bases is of special interest in pharmaceutical research because numerous active substances contain basic functional groups. Capillary and conventional size LC separations of drug substances spiked with potential impurities were compared. In the case of the nonpolar drug levonorgestrel equal separation efficiency was readily attained by both techniques. The peaks of basic substances, however, showed extensive tailing when separated by capillary LC. The peak deformation was attributable to interactions of the basic substances with the polar inner surface of the fused silica capillaries employed in capillary LC and does not appear with the steel tubing generally used in conventional size LC. This drawback of capillary LC was overcome by use of deactivated fused silica capillaries for column hardware and transfer lines.

Amitriptyline↗

Evaluation of packed capillary liquid chromatography columns and comparison with conventional-size columns.

Apart from extracolumn effects peak dispersion in liquid chromatographic columns is caused by the column inlet, the packed bed, and the column outlet. A strategy applicable for independent evaluation of the individual sources of column band broadening was developed on the basis of the linear extrapolation method (LEM). This method was applied to compare the performance of packed capillary LC columns from various commercial suppliers with conventional-size columns. The columns differed widely in their performance with respect to peak shapes and widths for standard substances. The capillary columns were found well packed, but in some cases overall performance would benefit from improving the design of the area between the packed bed and the connecting capillaries, containing frits as well as dead volumes.

Chromatography, Liquid↗

Extracolumn band broadening in capillary liquid chromatography.

A commercially available capillary LC instrument was modified to investigate and control the contribution of different instrument components on extracolumn band broadening. Quantitative estimations of dispersion induced by several equipmental parts were carried out. Injection parameters could be optimized to achieve the theoretical value of 12 for a profile factor describing a rectangular sample profile. Additionally, an additive injector flow channel dependent dispersion effect was found. A practical approach for minimizing instrumental effects in capillary LC is suggested. The results were compared with those obtained with an HPLC instrument designed for conventional size columns.

Chromatography, Liquid↗