PubMed Health⌕ Search

Biomedical subjects

Ji-Bin Liu

Publications and source records attributed to Ji-Bin Liu.

At least 19 recordsLinked to original sources

Ultrasound guided site specific gene delivery system using adenoviral vectors and commercial ultrasound contrast agents.

We have evaluated if ultrasound imaging (US) and various commercially available contrast microbubbles can serve as a non-invasive systemically administered delivery vehicle for site-specific adenoviral-mediated gene transfer in vitro and in vivo. The contrast agents were tested for their ability to enclose and to protect an adenoviral vector carrying the GFP marker gene (Ad-GFP) into the microbubbles. We have also evaluated the ability of the innate immune system to inactivate free adenoviruses as well as unenclosed viruses adsorbed on the surface of the contrast agents and in turn the ability of the microbubbles to enclose and to protect the viral vectors from such agents. In vitro as well as in vivo, innate components of the immune system were able to serve as inactivating agents to clear free viral particles and unenclosed adenoviruses adsorbed on the microbubbles' surface. Systemic delivery of Ad-GFP enclosed into microbubbles in the tail vein of nude mice resulted in specific targeting of the GFP transgene. Both fluorescence microscopy and GFP immunohistochemistry demonstrated US guided specific transduction in the targeted cells only, with no uptake in either heart, lungs or liver using complement-pretreated Ad-GFP microbubbles. This approach enhances target specificity of US microbubble destruction as a delivery vehicle for viral-mediated gene transfer.

Adenoviridae↗

Validating volume flow measurements from a novel semiautomated four-dimensional Doppler ultrasound scanner.

RATIONALE AND OBJECTIVES: Accurate measurement of blood volume flow (in ml/min) is an important clinical goal. This project compared in vitro and in vivo volume flow measurements obtained with a novel, real-time three-dimensional (i.e., four-dimensional) ultrasound scanner (Encore PV; Vuesonix Sensors, Wayne, PA) with those from an invasive transit time flowmeter. MATERIALS AND METHODS: A flow pump was used to generate pulsatile flow rates from 60 to 600 ml/min. The Encore detected absolute blood velocity vectors within a volume. The scanner determined the centerline of the vessel and volume flow was then automatically calculated. Results were compared with those of an invasive technique for volumetric blood flow measurements utilizing a transit-time flowmeter (TS420; Transonic Systems Inc., Ithaca, NY). In vivo, 10 second datasets of the volume flow in the distal aorta of six rabbits were obtained simultaneously with the Encore PV and the flowmeter. Data were compared using linear regression and Bland-Altman analysis (due to the lack of independence). RESULTS: In vitro, Encore and flowmeter measurements both matched the flow pump (r2 > 0.99; P < .0001) with mean errors of -11.8% and -0.3%, respectively. Marked underestimation of the true flow rates was encountered with the Encore at the lowest pump setting. In vivo mean volume flows between 10.6 and 79.3 ml/min were measured. Mean and maximum volume flows obtained with the two techniques correlated significantly (P < .0001) with r2 values of 0.86 and 0.62, respectively. The corresponding root-mean-square errors were 6.9% for mean flow and 61.2% for maximum volume flow measurements. CONCLUSION: A new semiautomated four-dimensional Doppler device has been tested in vitro and in vivo. Mean volume flow measurements with this unit are comparable to those of an invasive flowmeter.

Blood Flow Velocity↗

Contrast enhanced ultrasound for radio frequency ablation of canine prostates: initial results.

PURPOSE: We determined the feasibility of contrast enhanced ultrasound for radio frequency ablation of the entire prostate as a method of minimally invasive treatment for prostate cancer in a canine model. MATERIALS AND METHODS: Approval of the Institutional Animal Use and Care committee was obtained. Initially 5 dogs (group 1) were tested using variable power (5 to 30 W), time (4 to 12 minutes), bolus (0.01 to 0.04 ml/kg) and infusion (3 to 11 ml per minute at 0.015 microl/kg) injections of an ultrasound contrast agent with conventional grayscale power Doppler and pulse inversion harmonic imaging to establish optimal parameters. Subsequently 4 dogs (group 2) underwent entire prostate ablation using parameters based on group 1. The size of the thermal lesions and residual viable tissue was measured with ImageJ software (National Institutes of Health, Bethesda, Maryland) on ultrasound and pathological study. Linear regression and Student's t test were used for statistical analysis. RESULTS: A bolus of 0.04 ml/kg, an infusion of 11 ml per minute at 0.015 microl/kg and the contrast enhanced pulse inversion harmonic imaging mode were ranked best for guiding ablation. Thermal lesion volume was proportional to ablation power and time. There was no significant difference in measured thermal lesion size in group 1 between ultrasound and pathological findings (mean +/- SD 1.51 +/- 0.74 and 1.46 +/- 0.74 cm3, p = 0.56) or in residual viable tissue in group 2 (0.43 +/- 0.043 and 0.41 +/- 0.291 cm3, p = 0.21). The average volume of prostate ablation achieved in group 2 was 96.3%. CONCLUSIONS: Contrast enhanced pulse inversion harmonic imaging is able to guide, monitor and control radio frequency ablation of the entire prostate.

Animals↗

In vivo perfusion estimation using subharmonic contrast microbubble signals.

OBJECTIVE: The purpose of this study was to quantify perfusion in vivo using contrast-enhanced subharmonic imaging (SHI). METHODS: A modified LOGIQ 9 scanner (GE Healthcare, Milwaukee, WI) operating in gray scale SHI mode was used to measure SHI time-intensity curves in vivo. Four dogs received intravenous contrast bolus injections (dose, 0.1 mL/kg), and renal SHI was performed. After 3 contrast agent injections, a microvascular staining technique based on stable (nonradioactive) isotope-labeled microspheres (BioPhysics Assay Laboratory Inc, Worcester, MA) was used to quantify the degree of perfusion in 8 sections of each kidney. Low perfusion states were induced by ligating surgically exposed segmental renal arteries followed by contrast agent injections and microvascular staining. Digital clips were transferred to a personal computer, and SHI time-intensity curves were acquired in each section using Image-Pro Plus software (Media Cybernetics, Silver Spring, MD). Subharmonic fractional blood volumes were calculated, and the perfusion was estimated from the initial slope of the fractional blood volume uptake averaged over 3 injections. Subharmonic perfusion data were compared with the gold standard (ie, the microspheres) using linear regression analysis. RESULTS: In vivo gray scale SHI clearly showed flow and, thus, perfusion in the kidneys with almost complete suppression of tissue signals. In total, 270 SHI time-intensity curves were acquired, which reduced to 94 perfusion estimates after averaging. Subharmonic perfusion estimates correlated significantly with microsphere results (r = 0.57; P < .0001). The best SHI perfusion estimates occurred for high perfusion states in the anterior of the kidneys (r = 0.73; P = .0001). The corresponding root mean square error was 2.4%. CONCLUSIONS: Subharmonic perfusion estimates have been obtained in vivo. The perfusion estimates were in reasonable to good agreement with a microvascular staining technique.

Albumins↗

In vivo elastographic investigation of ethanol-induced hepatic lesions.

Ethanol-induced hepatic lesions were investigated in swine for in vivo use as a strain imaging animal model. Lesions (n = 25) were induced by injecting ethanol (doses 0.33 to 2.0 mL) directly into the surgically exposed liver at depths of 12, 15 or 25 mm. Lesions were imaged with a modified HDI 1000 scanner (Philips Medical Systems, Bothell, WA, USA). The elastograms (n = 91) characterized lesions as being areas harder than the surrounding soft hepatic tissue. Elastographic lesion sizes and the corresponding injected ethanol dose used to induce the lesions were shown to be statistically significant (r(2) = 0.22; p = 0.029) using a linear regression analysis. Additionally, lesion depth was shown to be statistically insignificant (r(2) < 0.12; p > 0.10) when regressed against elastographic lesion size. An analysis of elastographic and gross pathology lesion sizes indicated no correlation (r(2) < 0.01; p = 0.973). Subsequently, lesion types were sorted by size and regression lines were computed from quasilinear regions of the corresponding run charts. Trend lines indicate a four-to-three size relationship between the selected elastographic and pathology lesion sizes. Comparison of elastogram lesion sizes from two independent observers using a paired t-test resulted in no statistically significant difference (p = 0.14). In conclusion, ethanol-induced hepatic lesions in swine is a suitable animal model for evaluation of strain-based imaging systems, due to the ease of generation and repeatability.

Animals↗

In vivo pressure estimation using subharmonic contrast microbubble signals: proof of concept.

Changes in ambient pressure affects the reflectivity of ultrasound contrast microbubbles leading to an excellent correlation between subharmonic signals and hydrostatic pressure. The aortas of two dogs were scanned with an experimental pulse-echo system to validate in vivo pressure estimation based on subharmonic microbubble signals. Results matched well with instantaneous pressure measurements (from 20-60 mmHg) obtained simultaneously with a pressure catheter (root mean square errors <27%).

Algorithms↗

Contrast-enhanced sonographic imaging of lymphatic channels and sentinel lymph nodes.

OBJECTIVE: The purpose of this study was to determine whether lymphatic channels (LCs) and sentinel lymph nodes (SLNs) could be detected on sonographic imaging after subcutaneous, submucosal, or parenchymal injections of a sonographic contrast agent (ie, lymphosonography) in a variety of anatomic locations in several animal models. METHODS: Eight swine, 7 canines, 4 rabbits, and a monkey were used for these evaluations. Gray scale pulse inversion harmonic imaging of the LCs and the SLNs was performed after subcutaneous (n = 58), submucosal (n = 14), or parenchymal (n = 8) injections of a tissue-specific sonographic contrast agent (Sonazoid; GE Healthcare, Oslo, Norway). In many instances, blue dye was injected into the same locations as Sonazoid, and surgical dissection of the SLNs and LCs was performed for comparison. Scanning electron microscopy (SEM) of contrast-enhanced and control lymph nodes from 2 rabbits was performed to determine the mechanism of contrast agent uptake and retention within SLNs. RESULTS: After subcutaneous, submucosal, or parenchymal contrast agent injections, gray scale pulse inversion harmonic imaging could be used to identify the number and location(s) of LCs and SLNs. After subcutaneous, submucosal, or parenchymal contrast agent injections, Sonazoid was confined to the SLNs (ie, contrast enhancement was not detected in the second-echelon nodes). There was good agreement between the results of lymphosonography and blue dye with surgical dissection in identifying the regional LCs and SLNs. Scanning electron microscopy identified vacuoles representing intact contrast microbubbles within contrast-enhanced SLN macrophages, which were not present in the control lymph nodes. CONCLUSIONS: Lymphosonography can be used to detect lymphatic drainage pathways and SLNs in a variety of animal models.

Abdomen↗

Large liver tumors: protocol for radiofrequency ablation and its clinical application in 110 patients--mathematic model, overlapping mode, and electrode placement process.

PURPOSE: To establish a preoperative protocol for ultrasonographically guided percutaneous radiofrequency (RF) ablation of large liver tumors that is based on mathematic models and clinical experience and to evaluate the role of this protocol in RF ablation. MATERIALS AND METHODS: A regular prism and a regular polyhedron model were used to develop a preoperative protocol for liver tumor ablation. This protocol enabled the authors to minimize the number of ablation spheres, optimize the overlapping mode, and determine the electrode placement process. One hundred ten patients with 121 liver tumors were treated by using this protocol. Sixty-nine patients had 74 hepatocellular carcinomas (HCCs), and 41 had 47 metastases to the liver (ie, metastatic liver carcinomas [MLCs]). Patients underwent follow-up helical computed tomography (CT) 1 month and every 2-3 months after RF ablation. Ablation was considered a success if no contrast enhancement was detected in the treated area on the CT scan obtained at 1 month. RESULTS: A total of 536 ablations were performed in the 121 tumors. The ablation success rate was 87.6% (106 of 121 tumors); the local recurrence rate, 24.0% (29 of 121 tumors); and the estimated mean recurrence-free survival, 17.1 months. Twenty-five patients underwent 38 re-treatments for local tumor recurrence. Major complications occurred in seven patients. Of these patients, only one, who had a tumor close to the colon, had a colon perforation 1 week after RF and required surgical intervention. CONCLUSION: The described protocol for treatment of large tumors had a success rate of 87.6% and a local recurrence rate of 24.0%.

Adult↗

Effect of shell type on the in vivo backscatter from polymer-encapsulated microbubbles.

This study compared in vivo enhancement from four different polymer-encapsulated ultrasound (US) contrast agents. The agents were produced with a rigid shell composed of the biodegradable block copolymer poly[D,L-lactide-co-glycolide] (PLGA) with the lactic and glycolic acid ratios 50:50, 75:25, 85:15 and 100:0 (i.e., increasingly hydrophobic shell compositions). Approximately the same bubble diameter (1.2 microm) and concentration (0.4 g/mL) were obtained for each agent. In four rabbits, audio Doppler signals were acquired from a 10 MHz cuff transducer placed around a surgically exposed vessel (contrast dose: 0.0125 to 0.15 mL/kg). In vivo dose responses were calculated off-line (in dB). Nine rabbit kidneys were imaged during contrast administration (0.1 mL/kg) in power Doppler and grey-scale pulse inversion harmonic (PIHI) modes using an HDI 5000 scanner (Philips Medical Systems, Bothell, WA). Time-intensity curves were produced and the time-to-peak, peak intensity, slope, area under the curve (AUC) and total duration of enhancement for each agent were compared. All agents produced marked Doppler enhancement with increasing duration from the 50:50 agent (48 +/- 10 s) to the 75:25 agent (166 +/- 46 s), the 85:15 agent (403 +/- 83 s) and with the 100:0 agent (603 +/- 93 s) lasting longest (p < 0.02). No other parameters changed significantly, except the AUC of the 85:15 agent, which was greater than that of the 50:50 agent (190.75 vs. 61.58; p = 0.02). The in vivo dose-response curves were similar for all agents, with mean enhancement up to 20.6 +/- 1.11 dB (p = 0.17). In conclusion, contrast duration increases by an order of magnitude as the lactic acid component in the polymer-encapsulated bubbles increases and the shell, thus, becomes increasingly hydrophobic.

Animals↗

The incidence of crossing vessels in patients with normal ureteropelvic junction examined with endoluminal ultrasound.

PURPOSE: We estimated the incidence of a crossing vessel at the normal ureteropelvic junction (UPJ) in patients undergoing ureteroscopy and endoluminal ultrasonography for indications other than UPJ obstruction. MATERIALS AND METHODS: Endoluminal ultrasonography was performed in 141 patients undergoing upper tract endoscopy for various indications excluding UPJ obstruction. A detailed description of the anatomy of the UPJ as well as the location and size of crossing vessels was included in the operative note. Charts were reviewed to determine the precise anatomy of the UPJ. RESULTS: The overall incidence of crossing vessels at the unobstructed UPJ was 19.2%. Endoluminal ultrasonography demonstrated a crossing vessel in 13.2% of patients with ureteral narrowing or stricture, 31.3% of those with tumors or filling defects, 10.5% of those with submucosal calculi and 16.7% of patients with ureteral diverticula. In cases where the position of a crossing vessel was ascertained, 41% were anterior to the ureter, 28% anterolateral, 24% anteromedial and 7% posterior. There was a statistically significant difference in the frequency of vessels at the UPJ in patients with and without obstruction examined with endoluminal ultrasound (p <0.0001). CONCLUSIONS: A crossing vessel at the UPJ is seen with endoluminal ultrasound in 19.2% of patients with a normal UPJ. This incidence is lower than that seen in patients with obstructed UPJ. Many of these vessels are related to the lateral surface of the UPJ and there was no area that was always free of vessels.

Adolescent↗

Sentinel lymph nodes in a swine model with melanoma: contrast-enhanced lymphatic US.

PURPOSE: To determine if lymphatic channels and sentinel lymph nodes (SLNs) with and without metastases can be detected with lymphatic ultrasonography (US) after peritumoral injection of a US contrast agent and to determine if lymphatic US can be used to assess SLNs for the presence of metastatic infiltration. MATERIALS AND METHODS: Six swine with 17 melanomas were evaluated. Conventional gray-scale, color flow, and gray-scale phase-inversion harmonic US examinations were performed. A US contrast agent was administered in four sites around each melanoma (1-mL total dose). Lymphoscintigraphy was followed by injection of a blue dye and then dissection. SLNs identified at lymphatic US were characterized by two readers in consensus as normal or as having metastases; results were compared with histologic findings. Statistical analyses included the sign test and the kappa statistic. RESULTS: Lymphatic US depicted 28 SLNs, while lymphoscintigraphy depicted 27 "hot spots" suspected of representing SLNs (including two false-positive findings). Dissection after blue dye injection helped identify 31 SLNs. There were no false-positive US findings for SLN detection. Five of six nodes not seen with lymphoscintigraphy were detected with lymphatic US. The accuracy of SLN detection was 90% (28 of 31) for lymphatic US and 81% (25 of 31) for lymphoscintigraphy (P =.29). Lymphatic US correctly depicted metastases in 19 of 20 SLNs, and five of the eight normal SLNs were correctly characterized, with an accuracy of 86% (kappa = 0.62). CONCLUSION: Detection of SLNs with lymphatic US compared favorably with that at lymphoscintigraphy. Lymphatic US can depict metastases within the SLN, which was not possible with lymphoscintigraphy.

Animals↗

Mechanics and hemodynamics of esophageal varices during peristaltic contraction.

Our hypothesis states that variceal pressure and wall tension increase dramatically during esophageal peristaltic contractions. This increase in pressure and wall tension is a natural consequence of the anatomy and physiology of the esophagus and of the esophageal venous plexus. The purpose of this study was to evaluate variceal hemodynamics during peristaltic contraction. A simultaneous ultrasound probe and manometry catheter was placed in the distal esophagus in nine patients with esophageal varices. Simultaneous esophageal luminal pressure and ultrasound images of varices were recorded during peristaltic contraction. Maximum variceal cross-sectional area and esophageal luminal pressures at which the varix flattened, closed, and opened were measured. The esophageal lumen pressure equals the intravariceal pressure at variceal flattening due to force balance laws. The mean flattening pressures (40.11 +/- 16.77 mmHg) were significantly higher than the mean opening pressures (11.56 +/- 25.56 mmHg) (P < or = 0.0001). Flattening pressures >80 mmHg were generated during peristaltic contractions in 15.5% of the swallows. Variceal cross-sectional area increased a mean of 41% above baseline (range 7-89%, P < 0.0001) during swallowing. The peak closing pressures in patients that experience future variceal bleeding were significantly higher than the peak closing pressures in patients that did not experience variceal bleeding (P < 0.04). Patients with a mean peak closing pressure >61 mmHg were more likely to bleed. In this study, accuracy of predicting future variceal bleeding, based on these criteria, was 100%. Variceal models were developed, and it was demonstrated that during peristaltic contraction there was a significant increase in intravariceal pressure over baseline intravariceal pressure and that the peak intravariceal pressures were directly proportional to the resistance at the gastroesophageal junction. In conclusion, esophageal peristalsis in combination with high resistance to blood flow through the gastroesophageal junction leads to distension of the esophageal varices and an increase in intravariceal pressure and wall tension.

Adult↗

Catheter-based intraluminal sonography.

With the development of interventional and minimally invasive surgical techniques in the last decade, a strong interest in intraluminal sonography has arisen because of the need for better imaging information and management of the interventional procedure. High-resolution intraluminal sonography is a unique approach for the evaluation of a wide range of abnormalities within the luminal structures throughout the body. This imaging technique has been able to obtain information not available with even the most sophisticated percutaneous sonography, CT, or MRI. The uniqueness of this approach has led to extensive research, establishing a variety of clinical applications. These miniature catheter-based transducers have become important supplemental tools in the evaluation of the urinary and gastrointestinal tracts. Other areas need to be evaluated more thoroughly before efficacy is established, but the concept of using miniature transducers has shown promise in many areas of the body. This should lead to the provision of important information for decision making relative to patient care and surgical intervention. In the future, with projected technical progress, intraluminal sonography should substantially improve its diagnostic capabilities.

Catheterization↗

Peripheral nerve lesions: role of high-resolution US.

The peripheral nerve is demonstrated as a reticular pattern in a transverse section at high-resolution ultrasonography (US). Its echogenicity is between that of tendon and muscle. High-resolution US applied to lesions of peripheral nerves yields impressive results in that the nerve is highly differentiated from surrounding soft tissue. In cases of trauma, high-resolution US can easily differentiate between a rupture of the nerve bundle and fibroblast infiltration that results in traumatic neuroma. In cases of inflammation or compressive syndrome, high-resolution US can easily demonstrate lesion location and cause. In the evaluation of abnormal masses, high-resolution US cannot clearly differentiate neurofibromas from schwannomas but it can clarify the relationship between tumor and neural trunk and help the clinician plan treatment strategies. The authors discuss the success that can be achieved with the application of high-resolution US in the evaluation of peripheral nerve lesions.

Adult↗

Volume (3-dimensional) space-time reconstruction of esophageal peristaltic contraction by using simultaneous US and manometry.

BACKGROUND: Conventional 3-dimensional endoluminal US was modified to evaluate peristaltic contractions in the esophagus. METHODS: Two-dimensional US images and simultaneous intraluminal pressures were acquired during peristaltic contractions by locating the transducer at fixed positions in the esophagus in 6 normal volunteers during swallowing. Three-dimensional images were reconstructed by using a computer-based 3-dimensional algorithm with time as the x axis. RESULTS: The peristaltic contraction sequence was viewed as a 3-dimensional US image. The geometric configuration of the esophagus, the muscle thickness, and corresponding pressures were evaluated. The 3-dimensional images demonstrate 4 phases of the peristaltic contraction sequence. CONCLUSIONS: Three-dimensional time-resolved reconstruction of endoluminal US images of the esophagus and simultaneous recording of manometric data allow visualization of geometric changes and correlation with pressure changes during peristaltic contraction. Four phases of the peristaltic contraction sequence are demonstrated clearly on the 3-dimensional space-time images.

Adult↗

Comparing contrast-enhanced ultrasound to immunohistochemical markers of angiogenesis in a human melanoma xenograft model: preliminary results.

This study compared contrast-enhanced ultrasound (US) measures of tumor neovascularity with molecular markers of angiogenesis in a human melanoma xenograft model. A total of 14 mice were implanted with a human melanoma cell line (WM-9) in the thigh. After 2 to 3 weeks, a tumor, approximately 12 mm in diameter, developed. The US contrast agent Optison (Mallinckrodt, St. Louis, MO) was injected in a tail vein (dose: 0.4 to 0.6 mL/kg). Power Doppler and pulse-inversion harmonic imaging (HI) were performed with an Elegra scanner (Siemens Medical Systems, Issaquah, WA) and a 7.5 MHz linear array. Frame-rates of 30 Hz and 0.5 Hz (intermittent imaging) were used for pulse-inversion HI. After surgical removal, specimens were sectioned in the same planes as the US images. Immunohistochemical stains for endothelial cells (CD31), vascular endothelial growth factor (VEGF), basic fibroblast growth factor (bFGF) and cyclooxygenase-2 (COX-2) were performed. Two observers graded the stains (for intensity and percent area), and two other observers graded the US imaging modes (for fractional tumor neovascularity) on the same scale from 0 to 3. Of the 14 mice, 4 failed for technical reasons (i.e., n = 10). Linear regressions indicated statistically significant correlations between percent area stained with COX-2 and power Doppler (r = -0.789; p < 0.01), as well as intermittent pulse-inversion HI (r = -0.795; p < 0.05). There was a trend toward significance between percent area stained with VEGF and intermittent pulse-inversion HI (r = -0.720; 0.05 < p < 0.10). No other comparisons were significant. In conclusion, contrast-enhanced US measures of tumor neovascularity in a human melanoma xenograft model appear to provide a noninvasive marker of angiogenesis corresponding to expression of COX-2. However, the sample size of this study is small and, until further studies have been conducted, these conclusions are preliminary.

Albumins↗

Hepatic tumor detection: MR imaging and conventional US versus pulse-inversion harmonic US of NC100100 during its reticuloendothelial system-specific phase.

PURPOSE: To compare conventional ultrasonography (US) and magnetic resonance (MR) imaging with contrast agent-enhanced US for detection of VX-2 liver tumors in rabbits. MATERIALS AND METHODS: Conventional gray-scale liver US was performed in 65 rabbits, 38 of which had VX-2 hepatic tumor implants. Twenty minutes after contrast agent injection, gray-scale pulse-inversion harmonic US images of the liver-specific phase were obtained. Following sacrifice of the animals, T1- and T2-weighted MR imaging was performed at 4-mm intervals. Pathologic analysis was performed as the reference standard. The capability of each imaging modality to correctly depict tumor presence or absence and the number of tumors was compared. RESULTS: Conventional US correctly depicted the presence or absence of tumors in 54 rabbits, for an accuracy of 83%, sensitivity of 71%, and specificity of 100%. With contrast-enhanced US, accuracy increased to 92% (60 correct cases); sensitivity, to 87%; and specificity, to 100%. MR imaging facilitated 56 correct diagnoses, for an accuracy of 86%, sensitivity of 82%, and specificity of 93%. There was a marginally significant difference between US with and US without contrast agent (P =.07) but not between MR imaging and contrast-enhanced US (P > or = .34). When the numbers of correctly detected tumors were compared, contrast-enhanced US performed significantly better than MR imaging (P =.02) and conventional US (P =.04). CONCLUSION: There was no significant difference between contrast-enhanced US and MR imaging in the detection of hepatic tumors, whereas contrast-enhanced US had the highest accuracy (92%) of the three modalities studied.

Animals↗

Contrast-enhanced two- and three-dimensional sonography for evaluation of intra-abdominal hemorrhage.

OBJECTIVE: To determine whether a contrast agent enhances sonographic detection of bleeding sites in the abdomen and whether contrast-enhanced three-dimensional sonography provides additional information compared with contrast-enhanced two-dimensional sonography. METHODS: Bleeding sites were created within the livers (n = 3), spleens (n = 5), and kidneys (n = 3) of 3 dogs. A sonographic contrast agent with vascular and parenchymal enhancement capabilities was administered intravenously at a dose of 0.02 mL/kg. Before and after each contrast agent injection, the bleeding sites were imaged with two- and three-dimensional sonography in gray scale harmonic imaging and color flow modes. Sonographic findings were compared with gross pathologic findings. RESULTS: Noncontrast-enhanced sonography was not able to show the specific location of the active bleeding in any of the organs evaluated. The contrast agent enhanced the sonographic detection of blood flow in normal vessels and extravasated blood from damaged vessels or organs in all cases. Intrasplenic and intrahepatic hematomas were better identified on delayed imaging sequences because there was marked enhancement of the normal parenchyma, whereas the hematomas remained unenhanced. Reconstructed three-dimensional sonography showed spatial relationships of the bleeding sites and surrounding structures. Gross pathologic findings were consistent with the contrast-enhanced sonographic results. CONCLUSIONS: Contrast-enhanced sonography improves the detection and evaluation of abdominal bleeding sites. Contrast-enhanced three-dimensional sonography appears to provide additional information when compared with two-dimensional sonography.

Animals↗