PubMed Health⌕ Search

PubMed · 14992352

Catheter-based intraluminal sonography.

Abstract

With the development of interventional and minimally invasive surgical techniques in the last decade, a strong interest in intraluminal sonography has arisen because of the need for better imaging information and management of the interventional procedure. High-resolution intraluminal sonography is a unique approach for the evaluation of a wide range of abnormalities within the luminal structures throughout the body. This imaging technique has been able to obtain information not available with even the most sophisticated percutaneous sonography, CT, or MRI. The uniqueness of this approach has led to extensive research, establishing a variety of clinical applications. These miniature catheter-based transducers have become important supplemental tools in the evaluation of the urinary and gastrointestinal tracts. Other areas need to be evaluated more thoroughly before efficacy is established, but the concept of using miniature transducers has shown promise in many areas of the body. This should lead to the provision of important information for decision making relative to patient care and surgical intervention. In the future, with projected technical progress, intraluminal sonography should substantially improve its diagnostic capabilities.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ji-Bin Liu, Barry B Goldberg. 2004. Catheter-based intraluminal sonography.. https://doi.org/10.7863/jum.2004.23.2.145

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune heparin-induced thrombocytopenia resulting from preceding exposure to heparin catheter flushes.

Immune heparin-induced thrombocytopenia (HIT) is a life-threatening adverse effect of heparin. It can result from any type of heparin exposure and by any route of administration; however only a few cases are reported after exposures to small quantities of heparin from catheter flushes. The major clinical problem associated with HIT is thrombosis. Early detection and institution of alternative, non-heparin anticoagulation are important. We report a patient with HIT associated with use of therapeutic-dose unfractionated heparin in whom immune sensitization to heparin was triggered by two 500-unit exposure to UFH associated with intravascular catheter flushing for antineoplastic chemotherapy in a patient with colon adenocarcinoma.

Catheterization↗