Retention behavior of C1-C6 aliphatic monoamines on anion-exchange and polymethacrylate resins with heptylamine as eluent.

Retention behavior of C1-C6, aliphatic monoamines (methylamine, ethylamine, propylamine, butylamine, amylamine and hexylamine) on columns (150 mm x 6 mm i.d.) packed with various anion-exchange resins (styrene-divinylbenzene (PS-DVB) copolymer-based strongly basic anion-exchange resin: TSKgel SAX, polymethacrylate-based strongly basic anion-exchange resin: TSKgel SuperQ-5PW and polymethacrylate-based weakly basic anion-exchange resin: TSKgel DEAE-5PW) and unfunctionized polymethacrylate resins (TSKgel G5000PW and TSKgel G3000PWXL) was investigated with basic solutions (sodium hydroxide and heptylamine) as the eluents. Due to strongly electrostatic repulsion (ion-exclusion effect) between these anion-exchange resins and these amines, peak resolution between these amines on these anion-exchange resin columns was unsatisfactory with both sodium hydroxide and heptylamine as the eluents. In contrast, these polymethacrylate resins were successfully applied as the stationary phases for the separation of these C1-C6 amines with heptylamine as eluent, because of both small hydrophobicity and small cation-exchange ability of these resins. Excellent simultaneous separation, highly sensitive conductimetric detection and symmetrical peaks for these C1-C6 amines were achieved on the TSKgel G3000PWXL column in 35 min with 5 mM heptylamine at pH 11.1 as the eluent.

Amines↗

Split flow and bypass flow systems for monolithic capillary columns in liquid chromatography.

Split flow and bypass flow systems were assembled using Nano Y Connectors with low dead volume commercially available for capillary liquid chromatography (LC). The split ratio could be controlled by changing the dimension of restriction tubing and applied back pressure to the restriction tubing. The split flow system allowed us to use valve injectors and pumps commercially available for capillary LC. The reproducibility of the present split flow system was acceptable. The relative standard deviation for six successive measurements was 0.4% for the retention time, whereas that for the peak height and peak area was 1-3% depending on the analytes. The bypass flow system uses two Nano Y Connectors, where the eluent split at the first Nano Y Connector, which is located in the inlet of the separation column, is merged again into the effluent from the column at the second Nano Y Connector. The bypass flow system could avoid on-column detection and allowed us to use flow cells, leading to an approximate three times improvement in signal-to-noise. The present flow systems were evaluated by using aromatic hydrocarbons and alkylbenzenes as test analytes.

Chromatography, Liquid↗

Simultaneous determination of inorganic nitrogen species by microcolumn ion chromatography.

Inorganic nitrogen species (nitrate, nitrite and ammonium ions) were simultaneously determined by microcolumn ion chromatography. Nitrate and nitrite were determined by UV detection at 206 nm, whereas ammonium ion was determined by fluorescence detection at excitation 410 nm and emission 470 nm. The latter fluorescence detection is based on the postcolumn reaction of ammonium ion with o-phthalaldehyde in the presence of 2-mercaptoethanol. Effects of the reagent concentration, pH, and other reaction conditions on the signal intensity were examined, and the optimum condition was explored. The present method allowed simultaneous determination of nitrate, nitrite and ammonium ions in river water.

Chromatography↗

Separation of aliphatic carboxylic acids and benzenecarboxylic acids by ion-exclusion chromatography with various cation-exchange resin columns and sulfuric acid as eluent.

The application of various hydrophilic cation-exchange resins for high-performance liquid chromatography (sulfonated silica gel: TSKgel SP-2SW, carboxylated silica gel: TSKgel CM-2SW, sulfonated polymethacrylate resin: TSKgel SP-5PW, carboxylated polymethacrylate resins: TSKgel CM-5PW and TSKgel OA-Pak A) as stationary phases in ion-exclusion chromatography for C1-C7 aliphatic carboxylic acids (formic, acetic, propionic, butyric, isovaleric, valeric, isocaproic, caproic, 2-methylhexanoic and heptanoic acids) and benzenecarboxylic acids (pyromellitic, trimellitic, hemimellitic, o-phthalic, m-phthalic, p-phthalic, benzoic, salicylic acids and phenol) was carried out using diluted sulfuric acid as the eluent. Silica-based cation-exchange resins (TSKgel SP-2SW and TSKgel CM-2SW) were very suitable for the ion-exclusion chromatographic separation of these benzenecarboxylic acids. Excellent simultaneous separation of these benzenecarboxylic acids was achieved on a TSKgel SP-2SW column (150 x 6 mm I.D.) in 17 min using a 2.5 mM sulfuric acid at pH 2.4 as the eluent. Polymethacrylate-based cation-exchange resins (TSKgel SP-5PW, TSKgel CM-5PW and TSKgel OA-Pak A) acted as advanced stationary phases for the ion-exclusion chromatographic separation of these C1-C7 aliphatic carboxylic acids. Excellent simultaneous separation of these C1-C7 acids was achieved on a TSKgel CM-5PW column (150 x 6 mm I.D.) in 32 min using a 0.05 mM sulfuric acid at pH 4.0 as the eluent.

Benzene Derivatives↗

Simultaneous separation of inorganic anions and cations by using anion-exchange and cation-exchange columns connected in tandem in ion chromatography.

Inorganic anions and cations in environmental waters were determined by ion chromatography. Stationary and mobile phases were examined for the simultaneous separation of both anions and cations. Cations detection by UV detection requires a mobile phase with a UV absorbing additive, which indirectly visualizes cations as negative peaks. Simultaneous separation of anions and cations were achieved when using an eluent that consists of inorganic acid with weak basic amino acid as additives. It was convenient to separate both anions and cations by coupling anion-exchange and cation-exchange columns in tandem. The order of the separation columns connected affected the elution profiles. When the eluent comprises of multiple anions and a single cation, the anion-exchange column should be connected in the upper stream, whereas when the eluent comprises multiple cations and a single anion, the cation-exchange column should be connected in the upper stream. Use of switching valves also allowed simultaneous separation of anions and cations in a single chromatographic run. In the present work, operating conditions were optimized for the simultaneous separation of anions and cations.

Anion Exchange Resins↗

Comparison of monomeric and polymeric chiral stationary phases.

Two-type polymeric chiral stationary phases (pCSPs) were prepared by surface grafting of chiral acryl-type monomers on a silica gel surface modified with 3-(trimethoxysilyl)propylmethacrylate. The prepared pCSPs were characterized by IR, Fr-Raman, scanning electron microscopy, and elemental analysis. In addition, two-type monomeric chiral stationary phases (mCSPs) were also prepared. The racemic analytes were separated using the prepared mCSPs and pCSPs. The separation factor (alpha) and capacity factor (k1) of the racemic analytes for the pCSP and mCSP were compared. The alpha and k1 values of the mCSP were higher than those of the pCSP.

Chromatography, Liquid↗

Determination of inorganic anions via postcolumn reaction with iodide in ion chromatography.

Inorganic anions were determined as triiodide by postcolumn reaction with iodide under an acidic condition with help of alpha-cyclodextrin in ion chromatography. Analytes reacting with iodide to produce iodine could be determined by the present method. The analytes were indirectly detected at 287 or 355 nm. The presence of alpha-cyclodextrin caused an increase in the concentration of triiodide, leading to improvement of the sensitivity. The present system achieved good selectivity to iodate, bromate and nitrite as well as good repeatability under the optimum conditions. The determination of nitrite in river water was possible.

Anions↗

Surface grafting of glycidyl methacrylate on silica gel and polyethylene beads.

Surface grafting of glycidyl methacrylate (GMA) on silica gel and a polyethylene bead was performed by radical polymerization and radiation-induced polymerization, respectively, in order to improve softness. Subsequently, diethylene triamine (DETA), triethylene tetraamine (TETA), and iminodiacetic acid (IDA) were introduced to the grafted GMA for use as affinity columns. The efficiency of the affinity column was investigated by use of bovine serum albumin (BSA) and hemoglobin (Hb) as model proteins. The affinity degree of BSA was higher than Hb for the DETA and TETA column, whereas the affinity degree of Hb was higher than BSA for the IDA column supported by silica gel. The affinity degree of BSA was higher than Hb for the DETA and TTA column supported by polyethylene (PE) beads.

Amines↗

Study of carbon nanotubes-HRP modified electrode and its application for novel on-line biosensors.

In this paper, multi-walled carbon nanotubes (MWCNTs) were successfully immobilized on the surface of a glassy carbon electrode by mixing with horse-radish peroxidase (HRP). The electrochemical behavior of H2O2 was also studied with the MWCNTs-HRP modified electrode as a working electrode. The MWCNTs-HRP modified electrode showed excellent response of reduction current for the determination of H2O2 at the potential of -300 mV (vs. Ag/AgCl). We assembled the MWCNTs-HRP modified electrode in a thin-layer flow cell and the H2O2 solution was continuously introduced into the cell with a syringe pump. We optimized the sensitivity of the H2O2 sensor by adjusting the working potential and the pH of the buffer solution. The peak current increased linearly with the concentration of H2O2 in the range 3.0 x 10(-7) to approximately 2.0 x 10(-4) mol L(-1). The detection limit is 1.0 x 10(-7) mol L(-1) (S/N = 3). The interferences from ascorbic acid, uric acid and other electroactive substances can be greatly excluded since the sensor can be operated at -300 mV. Stability and reproducibility of the MWCNTs-HRP chemically modified electrode were also studied in this paper. Fabricated with glucose and lactate oxidase, the MWCNTs-HRP electrode was also applied to prepare the on-line glucose and lactate biosensors because of the high sensitivity for the determination of H2O2.

Biosensing Techniques↗

Pressure-controlled on-column injection method for microcolumn liquid chromatography.

A pressure-controlled on-column injection method was developed for microcolumn liquid chromatography. The system was assembled from a syringe pump, a Model M-445 Six-Way Micro Selection Valve, a separation column and a UV detector. The injection volume could be regulated by changing the applied pressure and/or the sample loading time. The system was evaluated in the ion-exchange mode. The system was applied to the determination of anions in river-water samples.

Journal Article↗

Determination of inorganic anions in natural water by microcolumn ion chromatography with on-column enrichment.

An on-column enrichment method was developed for the rapid determination of inorganic anions in natural water. The system was assembled from a syringe pump, a six-port switching valve with a sample-enrichment loop, a separation column and a UV detector. The enrichment efficiency of the system was tested by using inorganic anions as samples. The limits of detection were between 0.6 and 7.7 microg/L. The system was applied to the determination of anions in river and pond-water samples.

Journal Article↗

The study of nafion/xanthine oxidase/au colloid chemically modified biosensor and its application in the determination of hypoxanthine in myocardial cells in vivo.

A novel hypoxanthine (Hx) microsensor was constructed. In this work, Nafion xanthine oxidase (XOD) and Au colloid were immobilized onto the surface of a Pt microelectrode. The enzyme biosensor displayed a quick and sensitive response to Hx. Under physiological conditions, a low detection limit, with high selectivity and sensitivity for Hx determination were obtained. The oxidation current [investigated using current-time (I-t) plots] was linear with Hx concentration ranging from 2.0 x 10(-7) to 2.0 x 10(-5) mol L(-1) with a calculated detection limit of 1.0 x 10(-7) mol L(-1) (S/N of 3). The biosensor should be promising for in vivo measurement of Hx without interferences and fouling. The change of Hx concentration in cardiac myocytes stimulated by L-arginine (L-Arg) and acetylcholine (Ach) was also studied.

Biosensing Techniques↗

Liquid chromatographic determination of alcohols in food and beverages with indirect polarimetric detection using a beta-cyclodextrin mobile phase.

An indirect polarimetric detection method for the determination of alcohols has been proposed in liquid chromatography (LC). Optically active mobile-phase additives, such as beta-cyclodextrin (beta-CD), could be used to visualize optically inactive alcohols in reversed-phase LC. The visualization of alcohols is based on a perturbation of the partition of beta-CD caused by the alcohols. The detection limits of the present system at a signal-to-noise ratio of 3 were 0.031, 0.019, 0.018, 0.013, 0.011, 0.008 and 0.008% (v/v) for ethanol, 2-propanol, 1-propanol, 2-methyl-2-propanol, 2-butanol, 2-methyl-1-propanol and 1-butanol, respectively. The method was successfully applied to the determination of ethanol present in food and beverage samples.

Alcohols↗