PubMed Health⌕ Search

Biomedical subjects

Jim Luong

Publications and source records attributed to Jim Luong.

7 recordsLinked to original sources

Gas chromatographic applications with the dielectric barrier discharge detector.

With gas chromatography, there are many more choices for detectors when compared to other separation disciplines in analytical chemistry. The presence of sensitive and selective detectors aids in easing the separation requirements imposed on the capillary column. The current gas phase detectors, however, do not completely fulfill contemporary analytical needs. One example is in the area of ultratrace analysis of permanent gases for semiconductor industry. Another example is in the area of environmental/industrial hygiene monitoring for compounds such as 1,3-butadiene or vinyl chloride. The dielectric barrier discharge detector, a new highly sensitive detector with tuneable selectivity, has recently been innovated and commercialized. In this paper, the principle of operation of the detector, along with critical challenging industrial applications such as the analysis of oxygenated compounds, sulfur-containing compounds, and other compounds of industrial significance is presented.

Journal Article↗

Stacked injection with low thermal mass gas chromatography for PPB level detection of oxygenated compounds in hydrocarbons.

The presence of oxygenated compounds in light hydrocarbons can have a negative impact in manufacturing processes and on the quality of products produced. The development of an analytical technique termed "stacked injection" has been reported earlier. With this technique, sensitivity in the parts-per-billion (ppb) range for oxygenated compounds can be achieved, even with a flame ionization detector; however, there are drawbacks for this approach that limit its overall effectiveness. A new, improved analytical technique has been developed that not only addresses the shortcomings encountered, but offers markedly higher analytical performance. The new concept employs multidimensional gas chromatography (GC) with low thermal mass GC. With this new approach, throughput improvements of up to 5 times, range extension of solutes amenable for this analysis of up to nC16 alcohol, and ppb levels of detection for oxygenated compounds are achieved. Apart from alcohols, this technique is successfully employed for the ppb level analysis of other classes of oxygenated compounds, such as ethers, aldehydes, and aromatics.

Journal Article↗

Retention time reproducibility in comprehensive two-dimensional gas chromatography using cryogenic modulation. II. An interlaboratory study.

An interlaboratory survey was conducted to determine the reproducibility of retention times in both the first (1D) and second dimension (2D) axes of the two-dimensional separation space, using the longitudinal cryogenic modulation comprehensive two-dimensional gas chromatographic approach. Intralaboratory reproducibility has been demonstrated in part 1 of this investigation [J. Chromatogr. A 968 (2002) 161]. Confidence in absolute retention times (hence component positions) in the two-dimensional separation space is critical to component identification. Comparing data from four independent laboratories, five independent gas chromatographs, five independent LMCS units, and numerous operators has determined that the LMCS cryogenic modulation approach provides reliable comprehensive two-dimensional GC results.

Chromatography, Gas↗

Modulation techniques and applications in comprehensive two-dimensional gas chromatography (GC x GC).

More than a decade after Phillips' first published work this article reviews recent developments in comprehensive two-dimensional gas chromatography (GC x GC). Special attention is devoted to the further development and diversity of modulation devices. These include heated sweepers, cryofocused modulators, and a variety of diaphragm valve-switching strategies. It is demonstrated that all modulation approaches can be very well suited to GC x GC, depending on the particular application. Diaphragm-valve modulation is very powerful for volatile organic compounds. Slotted heater and cryofocused modulation are preferred for samples that contain non-volatile components. Applications ranging from petroleum to environmental and biological samples are illustrated. Extension of the technique to GC x GC-mass spectrometry (MS) is also discussed and trends for future research activity are pointed out.

Chromatography, Gas↗

Innovations in high-pressure liquid injection technique for gas chromatography: pressurized liquid injection system.

In gas chromatography (GC), highly volatile liquefied hydrocarbons are commonly injected using devices such as high-pressure syringes, piston valves, liquid rotary sampling valves, or vaporizing regulators. Although these techniques are adequate in some cases, there are known deficiencies. A new generation of sampling valve has been recently innovated and commercialized. Some of the highlights of the pressurized liquid injection system (PLIS) include compact size, the capability to directly couple to an injection port without the need for preinjection vaporization and transfer lines, and sample sizes ranging from 0.2 to 2.0 micro L. Although the valve has a specification of helium leak-free rating of 82.7 bar (1200 psig), the valve passes a hydrostatic pressure test of up to 414 bar (6000 psig). In the unheated version of PLIS, vaporization of solutes occur mainly because of the sheering effect of carrier gas in combination with thermal energy drawn from an injection port or a heated adaptor. This was found to be adequate for solutes with high to medium volatility of up to nC14 hydrocarbon. A higher molecular weight range of up to nC44 hydrocarbon can be achieved with the implementation of a heated version of PLIS, in which the channel of the shaft can be resistively heated at a rate of up to 400 degrees C/s. With its first introduction in May 2002, PLIS has gained acceptance amongst practitioners in GC because it addresses a key unarticulated need in sample introduction/enrichment and by specifically targeting many deficiencies encountered in contemporary high-pressure injection devices. In this paper, the design and performance of the various valve systems of PLIS, as well as industrial chromatographic applications, is presented.

Journal Article↗

Low thermal mass gas chromatography: principles and applications.

In gas chromatography (GC), temperature programming is often considered to be the second most important parameter to control, the first being column selectivity. A radically new GC technology to achieve ultrafast temperature programming with an unprecedented cool down time and low power consumption has recently become available. This technology is referred to as low thermal mass GC (LTMGC). Though the technology has its roots in resistive heating, which forms the basis of principle and design concept, the approach taken to achieve ultrafast heating and cool down time by LTMGC represents a significant break-through in GC. Despite some rectifiable shortcomings, LTMGC has proven to be an ideal methodology to deliver near/real time GC data, high precision, and high throughput applications. It is a new approach for modern high-speed GC. This paper documents the fundamental design principles behind LTMGC, performance data, and examples of applications investigated.

Journal Article↗

Gas chromatography with state-of-the-art micromachined differential mobility detection: operation and industrial applications.

Ion mobility spectrometry (IMS) has potential analytical applications in very diverse fields such as chemical, petrochemical, environmental, and, more recently, in drug, chemical warfare agent, and explosives detection. Commercially available IMS instruments are based on time-of-flight (TOF) mass spectrometry. IMS is inherently suitable for field operation as it uses relatively simple microfluidic devices and operates at atmospheric pressure. It is portable, highly sensitive with tunable selectivity, yet can be produced at relatively low cost. Key limitations of this analytical detection technique are low duty cycle, ion cluster formation, short linear dynamic range, and restriction to only positive or negative ion collection in a single analysis. Microelectromechanical system, radio frequency modulated IMS (MEMS RF-IMS), also known as differential mobility spectrometry, has recently been developed and commercialized. The technology is based on IMS, and MEMS RF-IMS offers substantially better performance. In this study, the strengths and limitations of the recently introduced differential mobility detector when used with gas chromatography in trace analyses are discussed and illustrated with applications of industrial significance.

Journal Article↗