PubMed Health⌕ Search

Biomedical subjects

Johan Nilsson

Publications and source records attributed to Johan Nilsson.

7 recordsLinked to original sources

On-line monitoring of airborne chemistry in levitated nanodroplets: in situ synthesis and application of SERS-active Ag-Sols for trace analysis by FT-Raman spectroscopy.

We report a new strategy for on-line monitoring of chemical reactions in ultrasonically levitated, nanoliter-sized droplets by Raman spectroscopy. A flow-through microdispenser connected to an automated flow injection system was used to dose picoliter droplets into the node of an ultrasonic trap. Taking advantage of the flow-through characteristics of the microdispenser and the versatility of the automated flow system, a well-defined sequence of reagents could be injected via the microdispenser into the levitated droplet placed in the focus of the collection optics of the Fourier transform Raman spectrometer. In that way, chemical reactions could be carried out and monitored on-line. The developed system was used for fast, reproducible, in situ synthesis of a highly active surface enhanced Raman scattering (SERS) sol resulting from the reduction of silver nitrate with hydroxylamine hydrochloride in basic conditions. With this chemical system, SERS substrate preparation could be achieved at room temperature and in short time. The in situ prepared silver sol was used for trace analysis of several organic test molecules that were injected into the levitated SERS-active droplet again using the microdispenser. The concentration dependence of the SERS spectra was studied using 9-aminoacridine, revealing that down to the femtogram region high-quality SERS spectra could be obtained. Additionally, SERS spectra of 6-mercaptopurine, thiamine, and acridine were recorded in the levitated drop as well.

Journal Article↗

Screening of nucleation conditions using levitated drops for protein crystallization.

The growth of suitable protein crystals is an essential step in the structure determination of a protein by X-ray crystallography. At present, crystals are mostly grown using trial-and-error procedures, and protocols that rapidly screen for the crystal nucleation step are rare. Presented here is an approach to minimize the consumption of precious protein material while searching for the nucleation conditions. Acoustically levitated drops of known protein concentration (0.25-1.5-microL volumes) are injected with crystallizing agents using piezoelectric flow-through dispensers (ejecting 50-100-pL droplets at 1-9000 droplets/s). A restricted number of crystallizing agents representing three classes are used: poly(ethylene glycol), salts, and the viscous alcohol 2-methyl 2,4-pentanediol. From a digitized picture of the levitated drop volume, calculations are performed giving the concentrations of all components in the drop at any time during a "precipitation experiment". Supersaturation is the prerequisite for crystal nucleation, and protein precipitation indicates high supersaturation. A light source illuminates the levitated drop, and protein precipitation is monitored using right-angle light scattering. On the basis of these intensity measurements and the volume determination, precipitation diagrams for each crystallizing agent are constructed that give the protein/crystallizing agent concentration boundaries between the minimum and the maximum detectable protein precipitation. Guided by the concentration values obtained from such plots, when approaching the supersaturation region, separate crystallization drops are mixed and allowed to equilibrate under paraffin oil. At conditions in which microcrystals can be observed, the nucleation tendency of the macromolecule is confirmed. Optimization of crystallization conditions can then follow. Proteins tested include alcohol dehydrogenase and D-serine dehydratase. Alcohol dehydrogenase, known to crystallize easily, was used to evaluate whether the ultrasonic field inhibits nucleation. Details are given for the screening procedure of D-serine dehydratase, an enzyme earlier found to be difficult to crystallize reproducibly. The time and material-saving qualities of this method are emphasized, since a range of conditions can quickly be screened using small amounts of protein to roughly determine solubility characteristics of a protein before crystallization trials are initiated.

Alcohol Dehydrogenase↗

Rapid topology mapping of Escherichia coli inner-membrane proteins by prediction and PhoA/GFP fusion analysis.

We present an approach that allows rapid determination of the topology of Escherichia coli inner-membrane proteins by a combination of topology prediction and limited fusion-protein analysis. We derive new topology models for 12 inner-membrane proteins: MarC, PstA, TatC, YaeL, YcbM, YddQ, YdgE, YedZ, YgjV, YiaB, YigG, and YnfA. We estimate that our approach should make it possible to arrive at highly reliable topology models for roughly 10% of the approximately 800 inner-membrane proteins thought to exist in E. coli.

Alkaline Phosphatase↗

On-chip microextraction for proteomic sample preparation of in-gel digests.

Despite the high sensitivity and relatively high tolerance for contaminants of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) there is often a need to purify and concentrate the sample solution, especially after in-gel digestion of proteins separated by two-dimensional gel electrophoresis (2-DE). A silicon microextraction chip (SMEC) for sample clean-up and trace enrichment of peptides was manufactured and investigated. The microchip structure was used to trap reversed-phase chromatography media (POROS R2 beads) that facilitates sample purification/enrichment of contaminated and dilute samples prior to the MALDI-TOF MS analysis. The validity of the SMEC sample preparation technique was successfully investigated by performing analysis on a 10 nM peptide mixture containing 2 m urea in 0.1 m phosphate-buffered saline with MALDI-TOF MS. It is demonstrated that the microchip sample clean-up and enrichment of peptides can facilitate identification of proteins from 2-DE separations. The microchip structure was also used to trap beads immobilized with trypsin, thereby effectively becoming a microreactor for enzymatic digestion of proteins. This microreactor was used to generate a peptide map from a 100 nM bovine serum albumin sample.

Electrophoresis, Gel, Two-Dimensional↗

Improved chip design for integrated solid-phase microextraction in on-line proteomic sample preparation.

A recently introduced silicon microextraction chip (SMEC), used for on-line proteomic sample preparation, has proved to facilitate the process of protein identification by sample clean up and enrichment of peptides. It is demonstrated that a novel grid-SMEC design improves the operating characteristics for solid-phase microextraction, by reducing dispersion effects and thereby improving the sample preparation conditions. The structures investigated in this paper are treated both numerically and experimentally. The numerical approach is based on finite element analysis of the microfluidic flow in the microchip. The analysis is accomplished by use of the computational fluid dynamics-module FLOTRAN in the ANSYS software package. The modeling and analysis of the previously reported weir-SMEC design indicates some severe drawbacks, that can be reduced by changing the microextraction chip geometry to the grid-SMEC design. The overall analytical performance was thereby improved and also verified by experimental work. Matrix-assisted laser desorption/ionization mass spectra of model peptides extracted from both the weir-SMEC and the new grid-SMEC support the numerical analysis results. Further use of numerical modeling and analysis of the SMEC structures is also discussed and suggested in this work.

Miniaturization↗

Ready-made matrix-assisted laser desorption/ionization target plates coated with thin matrix layer for automated sample deposition in high-density array format.

The methodology for ready-made matrix-assisted laser desorption/ionization (MALDI) target plates covered with an optimized thin layer consisting of matrix and nitrocellulose has been developed. Piezoelectric microdispensing enabled sample depositions in a high-density array format of 2000 sample depositions on a conventionally sized target plate (45 x 47 mm). The sample depositions were made reproducibly in a fully automated mode by using an in-house developed computer-controlled piezoelectric flow-through microdispenser. Additionally, the piezoelectric technique facilitated significant analyte enrichment that increased the detection sensitivity. The MS signal was obtained rapidly, generally within ten laser pulses. An airbrush device was used to generate a fine spray of matrix and nitrocellulose dissolved in acetone. The acetone evaporated instantly when reaching the target plate leaving the entire surface with a thin and uniform matrix/nitrocellulose coating consisting of very small crystals of matrix embedded in the nitrocellulose. These crystals acted as a seed-layer on subsequent analyte depositions, rendering homogeneous sample spots when using alpha-cyano-4-hydroxycinnamic acid (CHCA) as matrix. The relative standard deviation of the signal intensity between spots was (20-30)% (n = 30). The detection sensitivity was improved by restricting the sample spot diameter to 300 microm. The spot size was affected by the deposition rate and the evaporation rate of the dispensed sample volume. Mass spectra of a 25-amol peptide mixture deposition were successfully recorded.

Journal Article↗

Prediction of partial membrane protein topologies using a consensus approach.

We have developed a method to reliably identify partial membrane protein topologies using the consensus of five topology prediction methods. When evaluated on a test set of experimentally characterized proteins, we find that approximately 90% of the partial consensus topologies are correctly predicted in membrane proteins from prokaryotic as well as eukaryotic organisms. Whole-genome analysis reveals that a reliable partial consensus topology can be predicted for approximately 70% of all membrane proteins in a typical bacterial genome and for approximately 55% of all membrane proteins in a typical eukaryotic genome. The average fraction of sequence length covered by a partial consensus topology is 44% for the prokaryotic proteins and 17% for the eukaryotic proteins in our test set, and similar numbers are found when the algorithm is applied to whole genomes. Reliably predicted partial topologies may simplify experimental determinations of membrane protein topology.

Computational Biology↗