A recently introduced silicon microextraction chip (SMEC), used for on-line proteomic sample preparation, has proved to facilitate the process of protein identification by sample clean up and enrichment of peptides. It is demonstrated that a novel grid-SMEC design improves the operating characteristics for solid-phase microextraction, by reducing dispersion effects and thereby improving the sample preparation conditions. The structures investigated in this paper are treated both numerically and experimentally. The numerical approach is based on finite element analysis of the microfluidic flow in the microchip. The analysis is accomplished by use of the computational fluid dynamics-module FLOTRAN in the ANSYS software package. The modeling and analysis of the previously reported weir-SMEC design indicates some severe drawbacks, that can be reduced by changing the microextraction chip geometry to the grid-SMEC design. The overall analytical performance was thereby improved and also verified by experimental work. Matrix-assisted laser desorption/ionization mass spectra of model peptides extracted from both the weir-SMEC and the new grid-SMEC support the numerical analysis results. Further use of numerical modeling and analysis of the SMEC structures is also discussed and suggested in this work.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jonas Bergkvist, Simon Ekström, Lars Wallman, Mikael Löfgren, György Marko-Varga, Johan Nilsson, Thomas Laurell. 2002. Improved chip design for integrated solid-phase microextraction in on-line proteomic sample preparation.. https://doi.org/10.1002/1615-9861(200204)2%3A4%3C422%3A%3Aaid-prot422%3E3.0.co%3B2-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Microchips, microarrays, biochips and nanochips: personal laboratories for the 21st century.

Micro miniaturization of analytical procedures is having significant impact on diagnostic testing, and will enable highly complex clinical testing to be miniaturized and permit testing to move from the central laboratory into non-laboratory settings. The diverse range of micro analytical devices includes microchips, gene chips, bioelectronic chips. They have been applied to several clinically important assays (e.g., PCR, immunoassay). The main advantages of the new devices are integration of multiple steps in complex analytical procedures, diversity of application, sub-microliter consumption of reagents and sample, and portability. These devices form the basis of new and smaller analyzers (e.g., capillary electrophoresis) and may ultimately be used in even smaller devices useful in decentralized testing (lab-on-a-chip, personal laboratories). The impact of microchips on healthcare costs could be significant via timely intervention and monitoring, combined with improved treatments (e.g., microchip-based pharmacogenomic tests). Empowerment of health consumers to perform self-testing is limited, but microchips could accelerate this process and so produce a level of self-awareness of biochemical and genetic information hitherto unimaginable. The next level of miniaturization is the nanochip (nanometer-sized features) and the technological foundation for these futuristic devices is discernable in nanotubes and self-assembling molecular structures.

Miniaturization↗

Free focus radiography with miniaturized dental x-ray machines: a comparison of "midline" and "lateral" techniques.

The use of free focus radiography (FFR) employing miniaturized dental x-ray machines with radiation probes has never been generally accepted in dentistry despite its recognized radiographic potential. The present investigation studied ways to improve imaging and lower radiation burdens in dental free focus radiography. Relatively high air exposures ranging from 42,050 mR per film for high-resolution images to 3,214 mR per film for lower-resolution images using a current midline radiographic technique for panoramic FFR were found. In a proposed lateral FFR panoramic technique, reduced exposures ranged from 420 mR per film for high-resolution images to 14 mR per film for lower-resolution images. In each technique the lower exposure was obtained with a rare earth imaging system. A proposed modification of the current midline FFR technique using a rare earth imaging system and heavy added copper filtration was found to produce exposures in the range normally used in dentistry (207 mr), and the resultant image was high in contrast with relatively low detail. A comparison of essential characteristics of midline and lateral FFR techniques failed to identify specific advantages for the midline technique in current use. Lateral exposure modes in dental FFR should receive increased attention in the interest of good imaging and radiation control. It was noted that existing miniaturized dental x-ray machines may have been designed specifically for use of the midline FFR exposure technique, and modification of this equipment to support reliable lateral exposure modes was recommended.

Miniaturization↗