Monitoring the effect of mild hyperthermia on tumour hypoxia by Cu-ATSM PET scanning.

PURPOSE: Mild hyperthermia can improve tumour oxygenation and enhance radiosensitivity. Imaging the hypoxic fraction of a tumour can guide hyperthermia treatment planning and facilitate treatment optimization. 64Cu-ATSM (Copper-diacetyl-bis(N4-methylthiosemicarbazone)) is a positron emitting compound that has been demonstrated to have rapid uptake and selective retention in hypoxic cells and has been used for imaging human and animal tumours. The purpose of the present report is to establish methodology that will allow one to use Cu-ATSM PET scanning to detect the impact of hyperthermia on tumour physiology in as little time as possible. MATERIALS AND METHODS: EMT6 tumours (mouse mammary carcinoma) were implanted into the subcutaneous tissue of both thighs of 10 BALB/c mice (one heated, one control tumour per animal). The target thermal dose was 41.5 degrees C x 45 min. Without interrupting heating, 64Cu-ATSM (mean activity 1.8 mCi) was then injected and serial PET scans were obtained. In a sub-group of four animals, a low administered activity (approximately 0.3 mCi) 64Cu-ATSM scan was also conducted before heating to permit a direct comparison of the effects of hyperthermia on the same tumours. In another sub-group of five animals, a low activity (approximately 0.3 mCi) 64Cu-PTSM (pyruvaldehyde-bis(N*-methylthiosemicarbazone)) scan was conducted before heating, to confirm a posited correlation between perfusion and early 64Cu-ATSM uptake. RESULTS: This study corrected for perfusion differences by dividing tumour uptake by the average early (first minute) uptake ('self-normalized uptake'). The 10 heated tumours showed a significantly (p = 0.007) lower self-normalized uptake than control tumours by 2 min. For the four mice with low activity Cu-ATSM scans performed before hyperthermia, the tumours to be heated demonstrated self-normalized uptake consistent with the unheated control tumours and which departed significantly (p < or = 0.02) from their post-hyperthermia scans by 5 min. Comparisons between scans and needle electrode surveys were performed in an additional four animals with eight tumours. For technical reasons electrode surveys were done after the end of hyperthermia-and, therefore, these animals also had comparison scans taken after hyperthermia. Reduced self-normalized uptake on scans was associated with increased pO2 on electrode surveys. These data also suggested a substantial degradation of the effect on tumour hypoxia by approximately 15-45 min after the end of mild hyperthermia. CONCLUSION: Short imaging times of approximately 5 min with modest (approximately 4-10) numbers of mice can discriminate the effects of mild hyperthermia on tumour physiology. The long-term objective is to use this tool to identify as short and mild a hyperthermia session as possible.

Animals↗

Assessment of myocardial blood flow using 15O-water and 1-11C-acetate in rats with small-animal PET.

UNLABELLED: This feasibility study was undertaken to determine whether myocardial blood flow (MBF, mL/g/min) could be quantified noninvasively in small rodents using microPET and 15O-water or 1-11C-acetate. METHODS: MBF was measured in 18 healthy rats using PET and 15O-water (MBF-W) under different interventions and compared with direct measurements obtained with microspheres (MBF-M). Subsequently, MBF was estimated in 24 rats at rest using 1-11C-acetate (MBF-Ace) and compared with measurements obtained with 15O-water. Using factor analysis, images were processed to obtain 1 blood and 1 myocardial time-activity curve per tracer per study. MBF-W was calculated using a well-validated 1-compartment kinetic model. MBF-Ace was estimated using a simple 1-compartment model to estimate net tracer uptake, K1 (K1 (mL/g/min) = MBF.E; E = first-pass myocardial extraction of 1-11C-acetate) and washout (k2 (min(-1))) along with F(BM) (spillover correction) after fixing F(MM) (partial-volume correction) to values obtained from 15O-water modeling. K1 values were converted to MBF values using a first-pass myocardial extraction/flow relationship measured in rats (E = 1.0-0.74.exp(-1.13/MBF)). RESULTS: In the first study, MBF-W correlated well with MBF-M (y = 0.74x + 0.96; n = 18, r = 0.91, P < 0.0001). However, the slope was different than unity, P < 0.05). Refitting of the data after forcing the intercept to be zero resulted in a nonbias correlation between MBF-W and MBF-M (y = 0.95x + 0.0; n = 18, r = 0.86, P < 0.0001) demonstrating that the underestimation of the slope could be attributed to the overestimation of MBF-W for 2 MBF-M values lower than 1.50 mL/g/min. In the second study, MBF-Ace values correlated well with MBF-W with no underestimation of MBF (y = 0.91x + 0.35; n = 24, r = 0.87, P < 0.0001). CONCLUSION: MBF can be quantified by PET using (15)O-water or 1-11C-acetate in healthy rats. Future studies are needed to determine the accuracy of the methods in low-flow states and to develop an approach for a partial-volume correction when 1-11C-acetate is used.

Acetates↗

Techniques necessary for multiple tracer quantitative small-animal imaging studies.

INTRODUCTION: An increasing number and variety of studies on rodent models are being conducted using small-animal positron emission tomography scanners. We aimed to determine if animal handling techniques could be developed to perform routine animal imaging in a timely and efficient manner and with minimal effect on animal physiology. These techniques need to be reproducible in the same animal while maintaining hemodynamic and physiological stability. METHODS: The necessary techniques include (a) the use of inhalant anesthesia, (b) arterial and venous cannulation for multiple tracer administrations and blood sampling, (c) development of small-volume analytic columns and techniques and (d) measurement of the physiological environment during the imaging session. RESULTS: We provide an example of a cardiac imaging study using four radiotracers (15O-water, 1-[11C]-acetate, 1-[11C]-palmitate and 1-[11C]-glucose) injected into normal rats. Plasma substrates, CO2 production and total metabolites were measured. The animals remained anesthetized over the entire imaging session, and their physiological state was maintained. CONCLUSION: The intrastudy stability of the physiological measurements and substrate levels and interstudy reproducibility of the measurements are reported.

Animals↗

Measurement of input functions in rodents: challenges and solutions.

INTRODUCTION: Tracer kinetic modeling used in conjunction with positron emission tomography (PET) is an excellent tool for the noninvasive quantification of physiological, biological and molecular processes and their alterations due to disease. Currently, complex multi-compartment modeling approaches are being applied in a variety of clinical studies to determine myocardial perfusion, viability and glucose utilization as well as fatty acid metabolism and oxidation in the normal and diseased heart. These kinetic models require two key measurements of tracer activity over time, tracer activity in arterial blood (input function) and its corresponding activity in the organ of interest. The alteration in the time course of tracer activity as it travels from blood to the organ of interest describes the kinetics of the tracer. To be able to implement these approaches in rodent models of disease using small-animal PET (microPET), it is imperative that the input function is measured accurately. METHODS: The blood input functions in rodent experiments were obtained by (1) direct blood sampling, (2) direct measurement of blood activity by a beta-detecting probe that counts the activity in the blood, (3) an arterial-venous bypass (A/V shunt), (4) factor analysis of dynamic structures from dynamic PET images and (5) measurement from region-of-interest (ROI) analysis of dynamic PET images. Direct blood sampling was used as the reference standard to which the results of the other techniques were compared. RESULTS: Beta probes are difficult to operate and may not provide accurate blood input functions unless they are used intravenously, which requires complicated microsurgery. A similar limitation applies to the A/V shunt. Factor analysis successfully extracts the blood input function for mice and rats. The ROI-based method is less accurate due to limited image resolution of the PET system, which results in severe partial volume effect and spillover from myocardium. CONCLUSION: The current reference standard, direct blood sampling, is more invasive and has limited temporal resolution. With current imaging technology, image-based extraction of blood input functions is possible by factor analysis, while forthcoming technological developments are likely to allow extraction of input function directly from the images. These techniques will reduce the level of complexity and invasiveness for animal experiments and are likely to be used more widely in the future.

Animals↗

MicroPET assessment of androgenic control of glucose and acetate uptake in the rat prostate and a prostate cancer tumor model.

PET has been used to monitor changes in tumor metabolism in breast cancer following hormonal therapy. This study was undertaken to determine whether PET imaging could evaluate early metabolic changes in prostate tumor following androgen ablation therapy. Studies were performed comparing two positron-emitting tracers, 18F-FDG and 11C-acetate, in Sprague-Dawley male rats to monitor metabolic changes in normal prostate tissue. Additional studies were performed in nude mice bearing the CWR22 androgen-dependent human prostate tumor to evaluate metabolic changes in prostate tumor. In rats, for the androgen ablation pretreatment, 1 mg diethylstilbestrol (DES) was injected subcutaneously 3 and 24 hours before tracer injection. For androgen pretreatment, 500 microg dihydrotestosterone (DHT) was injected intraperitoneally 2 and 6 hours before tracer injection. The rats were divided into three groups, Group A (no-DES, no-DHT, n = 18), Group B (DES, no-DHT, n = 18) and Group C (DES, DHT, n = 18). In each group, 10 animals received 18F-FDG, whereas the remaining eight animals were administered 11C-acetate. Rats were sacrificed at 120 min post-injection of 18F-FDG or 30 min post-injection of 11C-acetate. Pretreatment of the mouse model using DHT (200 microg of DHT in 0.1 mL of sunflower seed oil) or DES (200 microg of DES in 0.1 mL of sunflower seed oil) was conducted every 2 days for one week. Mice were imaged with both tracers in the microPET scanner (Concorde Microsystems Inc.). DES treatment caused a decrease in acetate and glucose metabolism in the rat prostate. Co-treatment with DHT maintained the glucose metabolism levels at baseline values. In the tumor bearing mice, similar effects were seen in 18F-FDG study, while there was no significant difference in 11C-acetate uptake. These results indicate that changes in serum testosterone levels influence 18F-FDG uptake in the prostate gland, which is closely tied to glucose metabolism, within 24 hours of treatment and in the prostate tumor within 1 week. These early metabolic changes could enable monitoring metabolic changes in prostate tumor following treatment by imaging using 18F-FDG PET. Further studies are needed to clarify the reason for the insensitivity of 11C-acetate for measuring metabolic change in prostate tumor.

Acetates↗

Delineation of hypoxia in canine myocardium using PET and copper(II)-diacetyl-bis(N(4)-methylthiosemicarbazone).

UNLABELLED: Copper(II)-diacetyl-bis(N(4)-methylthiosemicarbazone) (copper-ATSM) is a hypoxia-avid tracer for the selective identification of hypoxic tissue. Using canine models of hypoxic myocardium, we report our findings on *Cu-ATSM PET (*Cu is defined as either (60)Cu, (61)Cu, or (64)Cu) for the delineation of ischemic and hypoxic myocardium. METHODS: In protocol I, myocardial hypoxia was induced by global hypoxia (n = 3). In protocol II, myocardial ischemia was generated by occlusion of the left anterior descending coronary artery (n = 9). In protocol III, coronary artery stenosis was induced by a stenosis in the left anterior descending coronary artery (n = 4). PET dynamic data were acquired immediately after tracer injection. Tracer retention kinetics were analyzed using either monoexponential analysis (1/k(mono)) or a simple 2-compartment model (1/k(4)). RESULTS: In protocol I, tracer retention in hypoxic myocardium was 2-fold greater than in normal myocardium, despite a 7-fold increase in blood flow (normal, 0.70 +/- 0.42 mL.min(-1).g(-1); hypoxic, 4.94 +/- 3.00 mL.min(-1).g(-1) [P < 0.005]). In protocol II, approximately 3 h after occlusion, retention of *Cu-ATSM within 20 min was greater in ischemic regions (myocardial blood flow, 0.28 +/- 0.26 mL.min(-1).g(-1)) than in normal tissue (myocardial blood flow, 0.52 +/- 0.19 mL.min(-1).g(-1)) (1/k(mono), 40.72 +/- 39.0 min vs. 26.69 +/- 22.29 min [P < 0.05]; 1/k(4), 6.85 +/- 4.90 min vs. 3.51 +/- 1.97 min [P < 0.05]). In selected dogs, tracer retention decreased at 24 h, suggesting the development of necrosis with no subsequent retention of *Cu-ATSM. In protocol III, dobutamine infusion after stenosis placement resulted in increased tracer retention consistent with hypoxia in the damaged regions. CONCLUSION: *Cu-ATSM PET has shown quantitative selective uptake in hypoxic myocardium within 20 min of tracer administration in 3 canine models of hypoxia.

Animals↗