PubMed Health⌕ Search

Biomedical subjects

John A Shepherd

Publications and source records attributed to John A Shepherd.

11 recordsLinked to original sources

Cross-calibration and minimum precision standards for dual-energy X-ray absorptiometry: the 2005 ISCD Official Positions.

The International Society for Clinical Densitometry (ISCD) Committee on Standards of Bone Measurement (CSBM) consists of experts in technical aspects of bone densitometry. The CSBM recently reviewed the scientific literature on cross-calibration and precision assessment. A report with recommendations was presented at the 2005 ISCD Position Development Conference (PDC). Based on a thorough review of the data by the ISCD Expert Panel during the conference, the ISCD adopted Official Positions with respect to (1) cross-calibration when changing or replacing hardware; (2) the approach to cross-calibration when an entire system is changed to one made by either the same or a different manufacturer; (3) when no cross-calibration study or bone mineral density (BMD) comparison is done between facilities; and (4) the minimum acceptable precision for an individual technologist. We present here the ISCD Official Positions on these topics that were established as a result of the 2005 PDC, together with the associated rationales and supportive evidence.

Absorptiometry, Photon↗

Clinical comparison of a novel breast DXA technique to mammographic density.

We compare mammography breast density (BD(MD)) to the measure of breast composition using a clinical dual energy absorptiometry (DXA) system (BD(DXA)) calibrated to measure breast density. A DXA scanning protocol was developed to scan breasts isolated in the DXA scan field in either a prone pendulous or decubitus mediolateral position. A total of 17 participants were recruited among women undergoing clinical mammography examinations. Each participant had duplicate DXA scans and duplicate craniocaudal-view mammograms of their right breast with repositioning between each scan and one DXA and one craniocaudal-view mammogram of their left breast. The in vivo repeatability (RMS SD) of BD(DXA) and BD(MD) on duplicate scans was found to be 1.2% for BD(DXA) and 1.4% for BD(MD) when repeat BD(MD) measures were made on the same day. When repeat BD(MD) measures of the same breast were made more than 50 days apart, the repeatability decreased to 5.5%. Left and right breast measurements were highly correlated with both techniques at r2 = 0.98 for BD(DXA) and r2 = 0.86 for BD(MD). Moderate correlation (r2 = 0.52) was found between BD(DXA) and BD(MD) measurements. However, after recalibrating the DXA system to mammography reference materials, negative percent fibroglandular values were measured for the most fatty breasts. Thus, our results are reproducible and accurate to common mammography tissue standards, but did not accurately reflect true percent fibroglandular levels and further development of phantom standards are necessary. We conclude that breast composition can be precisely evaluated and assessed with clinical DXA densitometers at a lower dose than with mammographic breast density methods.

Absorptiometry, Photon↗

Osteoporosis assessment by whole body region vs. site-specific DXA.

The ability of regional data from whole body scans to provide an accurate assessment of site-specific BMD, osteoporosis prevalence and fracture risk has not been fully explored. To address these issues, we measured total body (TBBD) and site-specific BMD in an age-stratified population sample of 351 women (21-93 years) and 348 men (22-90 years). We found an excellent correlation between AP lumbar spine and total body lumbar spine subregion BMD (r2=0.92), but weaker ones for total hip compared to pelvis region (r2=0.72) or between total wrist and left arm subregion from the whole body scan (r2=0.83). The error in estimating site-specific BMD from total body regions ranged from 4.3% (lumbar spine) to 11.2% (femoral neck) in women and from 4.9 to 11.1%, respectively, in men. Site-specific versus regional measurements at the lumbar spine and total hip/pelvis provided comparable overall estimates of osteoporosis prevalence, but disagreed on the status of individuals; measurements at whole body regions underestimated osteoporosis as assessed at the femoral neck or total wrist. All measurements were associated with a history of various fractures [age adjusted odds ratios (OR), 1.3 to 2.1 in women and 1.2 to 1.5 in men] and were generally interchangeable, but femoral neck BMD provided the best estimate of osteoporotic fracture risk in women (OR, 2.9; 95% CI, 1.7-5.0). Although there are strong correlations between BMD from dedicated scans of the hip, spine and distal forearm and corresponding regions on the whole body scan, the measurements provide somewhat different estimates of osteoporosis prevalence and fracture risk.

Absorptiometry, Photon↗

Novel use of single X-ray absorptiometry for measuring breast density.

Breast density is one of the strongest known breast cancer risk factors. Breast density has primarily been measured by either categorical scores of the proportion of opacity on a screening mammogram or as a ratio of the delineated dense area to the total breast area on a mammogram. These methods are limited by their subjectivity, their lack of absolute reference standards, and lack of automation for clinical use. We present a novel automated method for measuring breast composition we call Breast Compositional Density measured using single X-ray absorptiometry techniques, or BD(SXA). BD(SXA) measures breast compositional density by comparing the opacity on the mammogram to two reference standards imaged with each breast. We present the mathematical derivation of BD(SXA), methods for correcting for radiographic nonuniformity in the mammogram, and in vitro measures of accuracy and repeatability. Using phantoms, BD(SXA) has been shown to have a long-term repeatability of better than 2% for a breast composition range of 0 to 100% fibroglandular density.

Absorptiometry, Photon↗

Recalculation of the NHANES database SD improves T-score agreement and reduces osteoporosis prevalence.

UNLABELLED: In attempt to improve diagnostic agreement between manufacturers, a recent software update incorporated NHANES III data in GE Lunar densitometers. As a result, the femur neck and trochanter T-scores were lowered, and osteoporosis prevalence was increased. Use of a recalculated young-normal SD for the GE Lunar-adjusted NHANES III database improved diagnostic agreement and is recommended. INTRODUCTION: Use of manufacturer-specific normative databases for T-score derivation leads to discordance in T-score values and differences in diagnostic classification. To address this issue, the International Committee for Standards in Bone Measurement (ICSBM) recommended the NHANES III database for femur T-score derivation. Acquired on Hologic (Hol) instruments, this database requires conversion equations for application to other DXA systems. NHANES III total femur (TF) conversions for GE Lunar (GE) have previously been available, and femoral neck (FN) and trochanter (TR) equations were reported recently. Per the ICSBM recommendation, GE Lunar incorporated these values into their female database. This should produce T-score and diagnostic agreement between Hol and GE instruments; however, this has not been evaluated. MATERIALS AND METHODS: We compared GE femur scans in 115 postmenopausal women using software before and after the NHANES III software update. Subsequently, T-scores derived from femur scans obtained on GE and Hol densitometers were compared in a different group of 89 postmenopausal women. RESULTS: The NHANES III software update had no effect on measured BMD (g/cm2) at any femur region. However, because of changes in values used for T-score calculation (increase in the mean young-normal BMD at the FN and TR and a reduction in SD at the TR), the T-scores were lower (mean, 0.48 and 0.68, respectively) at the FN and TR using post-NHANES III software. Consequently, this update increased femur osteoporosis prevalence in these 115 women from 7.8% to 18.3%. Comparison of GE with Hol total proximal femur T-scores revealed a minimal difference (<0.1) and equal diagnoses of osteoporosis. FN and TR differences were larger, with mean GE T-scores lower than Hol (p < 0.001) by 0.17 and 0.50, respectively, thereby introducing osteoporosis diagnostic disagreement (13 [GE] versus 9 [Hol]). Our evaluation suggested that this disparity resulted from direct application of published NHANES III SDs at the FN and TR. As such, we applied the conversion formulae to the NHANES III published Hologic data and found the FN and TR SDs were greater than assumed by GE. Using our recalculated SD to derive T-scores reduced the mean GE/Hol T-score difference to 0.03 at the FN and 0.32 at the TR and resolved osteoporosis diagnostic disagreement. CONCLUSION: The GE NHANES III software update leads to lower FN and TR T-scores than obtained with Hol or prior GE software. Recalculation of the young-normal SD reduces this difference and is recommended. Clinicians are advised to avoid using the TR for diagnosis or, at a minimum, use caution when making treatment decisions based solely on T-score at this site.

Absorptiometry, Photon↗

Official positions of the international society for clinical densitometry.

The International Society for Clinical Densitometry (ISCD) periodically holds Position Development Conferences for the purpose of establishing standards and guidelines for indications, acquisition, and interpretation of bone density tests. Topics are selected for consideration by the ISCD Scientific Advisory Committee, reviewed by scientific working groups, and presented to an international panel of experts. Topic categories addressed to date include indications for bone density testing, selection of reference databases for T-scores and Z-scores, clinical applications for central and peripheral bone densitometry, serial bone density testing, instrument precision assessment, phantom scanning and calibration testing, requirements for a bone density report, nomenclature, and diagnosis of osteoporosis in postmenopausal women, premenopausal women, men, and children. After an open session for public comment and discussion, the panel convenes for consideration of each topic and makes recommendations for positions to the ISCD Board of Directors. Recommendations that are accepted become the Official Positions of the ISCD. This Special Report summarizes the methodology of the ISCD Position Development Conferences and presents selected Official Positions of general interest.

Absorptiometry, Photon↗

Accuracy of CT-based thickness measurement of thin structures: modeling of limited spatial resolution in all three dimensions.

Measurement of the width of thin structures such as the cortical shell of the vertebral body or femoral neck with computed tomography (CT) is limited by the spatial resolution of the CT system. Limited spatial resolution exists both within the CT image plane and perpendicular to it and can be described by the in-plane point spread function (PSF) and the across-plane slice sensitivity profile (SSP), respectively. The goal of this study was to confirm that errors of thickness measurement of thin structures critically depend on the spatial positioning of the object and the spatial resolution limitations of CT in all three dimensions, and to assess the size of the errors themselves. We compared computer models that incorporated both effects to experimentally assessed cortical thicknesses of the European Spine Phantom. Analysis included varying CT slice width, the orientation of measurement and angle beta of misalignment of longitudinal scanner and phantom axes. Agreement of models with measurements was good in all configurations with an overall error of 0.17 mm. This showed that PSF and SSP are adequate system characteristics to predict deviation of measured values from true widths. Errors between measurements and true cortical thickness values delta(true) averaged to 1.5 mm were strongly positively correlated with slice width d and beta. When the across-plane partial volume effect was eliminated, limited in-plane resolution still accounted for overestimation of delta(true) by 0.68 (137%), 0.27 (27%), and 0.06 mm (4%) for delta(true)=0.5, 1.0, and 1.5 mm, respectively. For delta(true) of 1.0 mm and above, it was shown that although the absolute cortical thickness values might not be accurately measurable, relative differences between two values are reflected in measurement. Implications for cortical thickness measurement are that the spinal cortical shell is too thin, whereas accurate assessment at locations of the femoral neck exhibiting a thicker cortical shell of both difference and absolute values should be possible with CT even for larger misalignment angles, especially when a smaller CT slice width is chosen.

Computer Simulation↗

Measurement of breast density with dual X-ray absorptiometry: feasibility.

Dual x-ray absorptiometry (DXA) was used to quantify breast density with a phantom and with cadaveric breasts. With DXA, percentage of fat correlated with percentage of glandular density of the phantom (r > 0.998) and with density at mammography (r(adjusted) = 0.83). DXA precision (SD) was 0.5% without and 1.1% with breast repositioning. DXA devices can be used to accurately and precisely estimate breast tissue density.

Absorptiometry, Photon↗

Universal standardization of forearm bone densitometry.

As part of an effort to quantify device-dependent differences in forearm bone density, 101 women, aged 20-80 years (approximately 16 women in each age decade), were scanned on six forearm bone densitometers: the Aloka DCS-600EX, the Hologic QDR-4500A, the Lunar PIXI, the Norland pDEXA, the Osteometer DTX-200, and the Pronosco X-posure System. Regression statistics are reported for all similar regions of interest (ROIs). However, comparisons were confounded because of large differences in the ROI size and placement. The number of ROIs reported for a single scan by each device varied from 1 to 12. The correlation coefficients ranged from 0.7 < r < 0.97, with the highest correlation coefficients and lowest SEs for comparisons between the most similar ROIs. Standardized units of bone mineral density are derived for distal (sdBMD), mid-(smBMD), and proximal (spBMD) ROTs that allow for comparable mean bone densities to be derived for patient populations. Five phantoms were scanned and characterized on five of the devices and the precision and mean values were reported. These phantom values will aid in the in vitro cross-calibration between manufacturers to recreate the presented in vivo relationships. Care should be exercised when using these equations for cross-calibrating patient databases or pooling clinical data from different devices because the least significant differences detectable from measurements taken on two different machines can be increased substantially.

Absorptiometry, Photon↗

Growth and metabolic consequences of bladder augmentation in children with myelomeningocele and bladder exstrophy.

OBJECTIVE: Bladder augmentation using intestinal segments is reported to cause decreased linear growth in bladder exstrophy and myelomeningocele patients. We studied changes in calcium metabolism, height, bone chemistry, and bone density in exstrophy and myelomeningocele patients after bladder augmentation. METHODS: Thirty-three patients were prospectively admitted to the Pediatric Clinical Research Center at the University of California San Francisco for 24 hours. Blood and urine were analyzed for electrolytes, and serum was obtained for markers of calcium metabolism. Dual radiograph bone densitometry of the forearm was performed. Myelomeningocele patients were compared with nonaugmented myelomeningocele patients matched by age, gender, level of defect, and ambulatory status. Exstrophy augmented patients were compared with nonaugmented exstrophy patients. The bone densities in both groups were compared with normal children. Laboratory values and percentile heights were statistically analyzed using the Student t test; bone densitometry was analyzed using the Tukey test. RESULTS: Twenty-two patients with myelomeningocele and 11 with bladder exstrophy were studied. Mean follow-up was 3.7 years postaugmentation (range: 1-13 years). The results indicate a significant difference in serum bicarbonate and chloride levels between myelomeningocele patients who underwent ileal augmentation and those who did not. Although this may be indicative of chronic metabolic acidosis, there was no affect on growth or bone density when compared with controls. There were no other significant differences in laboratory values, or percentile heights, nor were any differences noted in patients who underwent gastrocystoplasty. In the exstrophy group, there were no observable differences in percentile height or laboratory values between the augmented and nonaugmented group. There were no significant differences in bone density between these 2 groups when matched for age and gender. No significant difference was seen in bone density when these groups were compared with normal children. CONCLUSION: Bladder augmentation is safe and does not impact negatively on the linear growth or bone densities of patients with myelomeningocele or bladder exstrophy.

Adolescent↗

Accuracy of mammographic breast density analysis: results of formal operator training.

Mammographic density is a major risk factor for breast cancer. Breast density is not routinely quantified for research studies because present methods are time intensive and manual, and require expert training. We investigated whether individuals with and without backgrounds in radiology or medicine can achieve sufficient accuracy when compared with an expert (gold standard) reader of mammographic breast density. Nine readers (three radiologists, two non-radiology physicians, and four nonphysicians) assessed breast density on 144 digitized films (60 contralateral films of breast cancer cases and 84 controls) on a computer workstation with custom software. Readings were compared with a radiologist with training in mammography and density reading that read the same films. A correlation of r = 0.9 or higher with the gold standard reading was met by three of three radiologists, one of two nonradiology physicians, and one of four nonphysicians. Intrareader reproducibility measured as the residual sum of mean errors averaged 10% mammographic density for all readers and 9% for readers with a correlation of 0.9 or higher with the gold standard. The odds ratios associated with breast cancer when films with mammographic breast density of 50% or greater are considered "dense" ranged from 3.1 to 3.9 or a 1.9-2.4-per-population-SD increase in percentage density. Although it is advantageous to have a radiological background when quantifying mammographic density, it is not a prerequisite. Applying strict validation criteria to qualify readers to quantify mammographic breast density for research studies will enhance the chance of accurately assessing breast density and discriminating women at high and low risk of breast cancer.

Adult↗