PubMed Health⌕ Search

Biomedical subjects

John R Barr

Publications and source records attributed to John R Barr.

At least 19 recordsLinked to original sources

The use of Endopep-MS for the detection of botulinum toxins A, B, E, and F in serum and stool samples.

Botulinum neurotoxin (BoNT) causes the disease botulism, which can be lethal if untreated. Previous work in our laboratory focused on developing Endopep-MS, a mass spectrometric-based endopeptidase method for the detection and differentiation of BoNT serotypes. We have expanded this effort to include an antibody capture method to partially purify and concentrate BoNT from serum and stool extract samples for the Endopep-MS assay. Because complex matrices such as serum and stool contain abundant endogenous proteases, this technique was needed to remove most proteases from the sample while concentrating BoNT from a sample size of 100 to 500 microl to 20 microl. When this antibody capture method is combined with the Endopep-MS reaction, limits of detection in 500mul of spiked human serum are 10 mouse LD50 (20 mouse LD50/ml) for BoNT A, 0.5 mouse LD50 (1 mouse LD50/ml) for BoNT B, 0.1 mouse LD50 (0.2 mouse LD50/ml) for BoNT E, and 0.5 mouse LD50 (1 mouse LD50/ml) for BoNT F. The limits of detection in spiked stool extracts are somewhat higher due to the high-protease environment of stool extract that also requires use of protease inhibitors. The entire method can be performed in as short a time as 4 h.

Amino Acid Sequence↗

Exposure to bisphenol A from bis-glycidyl dimethacrylate-based dental sealants.

BACKGROUND: Bisphenol A (BPA) is a common component of composites and dental sealants. The potential exists for human exposure after sealant placement. METHODS: The authors prospectively enrolled 15 men in an exposure assessment study; 14 completed the study. After placement of clinically appropriate amounts of one of two sealants, the authors measured BPA in saliva and urine samples collected at prescribed intervals after the sealants were placed. They used selective and sensitive isotope-dilution mass-spectrometry-based methods for BPA measurements, thus providing the most reliable results. RESULTS: Helioseal F (Ivoclar Vivadent, Amherst, N.Y.) leached negligible amounts of BPA. Urinary and salivary BPA levels in subjects who received these sealants were similar to baseline levels. Delton Light Cure (LC) Opaque pit-and-fissure sealant (Dentsply/Ash, York, Pa.) leached more BPA, resulting in low-level BPA exposures similar to those used in laboratory animal testing. BPA exposure after Delton LC sealant placement was significantly higher than exposure after placement of Helioseal F. Patients treated with Delton LC had significantly higher doses of BPA (110 microg) than did those treated with Helioseal F (5.5 microg) (P < .0001). CONCLUSIONS: Placement of clinically relevant amounts of Delton LC sealant resulted in low-level BPA exposure; however, exposure was negligible after placement of Helioseal F. Saliva collection after sealant placement likely reduced systemic absorption of BPA from dental sealants. Sealants should remain a useful part of routine preventive dental practice, especially those that leach negligible amounts of BPA. CLINICAL IMPLICATIONS: Dental sealants may be a point source for low-level BPA exposure at levels that show health effects in rodents. Further research is required to determine whether human exposure to BPA at these levels causes adverse effects.

Adult↗

Detection of botulinum neurotoxin A in a spiked milk sample with subtype identification through toxin proteomics.

Botulinum neurotoxin (BoNT) causes the disease botulism, which can be lethal if untreated. Rapid determination of exposure to BoNT is an important public health goal. Previous work in our laboratory focused on the development of Endopep-MS, a mass spectrometry-based endopeptidase method for detecting and differentiating BoNT in buffer. This method can rapidly determine the presence of BoNT in a sample and differentiate the toxin type of BoNT present but does not yield additional information about the subtype. We now describe here the application of Endopep-MS to detect BoNT A in a spiked milk sample. This work also describes subtype identification achieved through mass spectrometric analysis of the protein toxin itself and does not require the presence of DNA from the toxin-producing bacteria. Tryptic digests of A1 and A2 subtypes of BoNT were analyzed by mass spectrometry, and peptides unique to either the A1 or A2 subtype were subjected to tandem mass spectrometry analysis to confirm their identities. Finally, subtype identification through mass spectrometric analysis was performed on BoNT A isolated from spiked milk. In its entirety, this method would allow for analysis of BoNT with toxin type identification in a few hours and subtype identification within 24 h.

Amino Acid Sequence↗

From the mouse to the mass spectrometer: detection and differentiation of the endoproteinase activities of botulinum neurotoxins A-G by mass spectrometry.

We have developed an assay (Endopep-MS) that detects the specific endoproteinase activities of all seven BoNT types by mass spectrometry (MS). Each BoNT type cleaves a unique site on proteins involved in neuronal transmission. Target peptide substrates based on these proteins identify a BoNT type by its enzymatic action on the substrate and the production of two peptide products, which are then detected by matrix-assisted laser desorption/ionization time-of-flight MS or liquid chromatography electrospray ionization MS/MS. We showed the ability to detect all seven toxin types in a multiplexed assay format. The detection limits achieved range from 0.039 to 0.625 mouse LD(50)/mL for toxin types A, B, E, and F in a buffer system. The Endopep-MS assay is the first to differentiate all seven BoNT types, is sensitive, specific, and has the potential to quantify toxin activity.

Amino Acid Sequence↗

Survey of albumin purification methods for the analysis of albumin-organic toxicant adducts by liquid chromatography-electrospray ionization-tandem mass spectrometry.

HSA has been shown to react with many organic toxicants to form adducts that are useful biomarkers for exposure. Albumin isolation is an important first step for the analysis of these protein-toxicant adducts. We tested several approaches to isolate albumin from serum treated with an electrophilic organic toxicant known to form adducts with albumin, i.e., sulfur mustard agent (HD) (2,2'-dichloroethyl sulfide), in order to evaluate these techniques as purification methods. To select the most efficient isolation strategy, methods were evaluated using gel electrophoresis, total protein quantitation, and peptide-adduct identification by MS. Results suggest that the albumin-rich fractions obtained can be used to identify exposure by quantitating the albumin adducts to electrophilic organic toxicants such as HD. The HiTrap Blue HP albumin isolation system appears to display the most promising results for purifying albumin to detect HD-adducts, exhibiting high purification efficiency, satisfactory albumin recovery, promising specificity, and a higher loading capacity for serum.

Chromatography, Liquid↗

Quantification of ricinine in rat and human urine: a biomarker for ricin exposure.

Ricin is a toxalbumin derived from the castor bean plant, Ricinus communis. Ricinine is an alkaloid (3-cyano-4-methoxy-N-methyl-2-pyridone) that shares a common plant source with ricin, and its presence in urine infers ricin exposure. A new quantification method for ricinine was developed that uses solid-phase extraction to prepare 1-mL urine samples (81% recovery) for a 5-min, isocratic high-performance liquid chromatography method, followed by electrospray ionization tandem mass spectrometry. Protonated molecular ions were selected in the multiple reaction monitoring mode and quantified by isotope dilution with (13)C(6)-labelled ricinine as the internal reference. Urine pools enriched with ricinine at two concentrations were characterized as quality control materials and then used to validate the method. The method limit of quantification was 0.083 ng/mL, even with a confirmation ion of low relative abundance. Ricinine was stable in human urine when heated at 90 degrees C for 1 h, and during storage at 25 degrees C and 5 degrees C for 3 weeks. The method was applied to an animal exposure study, a crude ricin preparation scheme, and a forensic analysis. These studies show that ricinine can be measured in rat urine at least 48 h after exposure. Ricinine is present in crude preparations of ricin, and it can be found in human urine after a lethal exposure to ricin.

Alkaloids↗

Personalized exposure assessment: promising approaches for human environmental health research.

New technologies and methods for assessing human exposure to chemicals, dietary and lifestyle factors, infectious agents, and other stressors provide an opportunity to extend the range of human health investigations and advance our understanding of the relationship between environmental exposure and disease. An ad hoc Committee on Environmental Exposure Technology Development was convened to identify new technologies and methods for deriving personalized exposure measurements for application to environmental health studies. The committee identified a "toolbox" of methods for measuring external (environmental) and internal (biologic) exposure and assessing human behaviors that influence the likelihood of exposure to environmental agents. The methods use environmental sensors, geographic information systems, biologic sensors, toxicogenomics, and body burden (biologic) measurements. We discuss each of the methods in relation to current use in human health research; specific gaps in the development, validation, and application of the methods are highlighted. We also present a conceptual framework for moving these technologies into use and acceptance by the scientific community. The framework focuses on understanding complex human diseases using an integrated approach to exposure assessment to define particular exposure-disease relationships and the interaction of genetic and environmental factors in disease occurrence. Improved methods for exposure assessment will result in better means of monitoring and targeting intervention and prevention programs.

Biomarkers↗

Botulinum neurotoxin detection and differentiation by mass spectrometry.

Botulinum neurotoxins (BoNTs) are proteases that cleave specific cellular proteins essential for neurotransmitter release. Seven BoNT serotypes (A-G) exist; 4 usually cause human botulism (A, B, E, and F). We developed a rapid, mass spectrometry-based method (Endopep-MS) to detect and differentiate active BoNTs A, B, E, and F. This method uses the highly specific protease activity of the toxins with target peptides specific for each toxin serotype. The product peptides derived from the endopeptidase activities of BoNTs are detected by matrix-assisted laser-desorption ionization time-of-flight mass spectrometry. In buffer, this method can detect toxin equivalents of as little as 0.01 mouse lethal dose (MLD)50 and concentrations as low as 0.62 MLD50/mL. A high-performance liquid chromatography-tandem mass spectrometry method for quantifying active toxin, where the amount of toxin can be correlated to the amount of product peptides, is also described.

Amino Acid Sequence↗

Identification of biomarkers of whole Coxiella burnetii phase I by MALDI-TOF mass spectrometry.

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) specific biomarkers have been shown to be an effective tool for identifying microorganisms. In this study, we demonstrate the feasibility of using this technique to detect the obligate intracellular bacterium Coxiella burnetii, a category B bioterrorism agent. Specific biomarkers were detected in C. burnetii Nine Mile phase I (NMI) strain purified from embryonated egg yolk sac preparations. Whole organisms were applied directly to the MALDI target. MALDI-TOF MS analysis of C. burnetii NMI grown and purified at different times and places revealed a group of unique, characteristic, and reproducible spectral markers in the mass range of 1000-25000 Da. Statistical analysis of the averaged centroided masses uncovered at least 24 peptides or biomarkers. Three biomarkers observed in the MALDI-TOF MS spectrum consistently matched proteins that had been previously described in C. burnetii, one of them being the small cell variant protein A. MALDI-TOF MS analysis of whole organisms represents a sensitive and specific option for characterizing C. burnetii isolates, especially when coupled with antigen capture techniques. The method also has potential for several applications in basic microbial research, including regulation of gene expression.

Animals↗

Standardization and denoising algorithms for mass spectra to classify whole-organism bacterial specimens.

MOTIVATION: Application of mass spectrometry in proteomics is a breakthrough in high-throughput analyses. Early applications have focused on protein expression profiles to differentiate among various types of tissue samples (e.g. normal versus tumor). Here our goal is to use mass spectra to differentiate bacterial species using whole-organism samples. The raw spectra are similar to spectra of tissue samples, raising some of the same statistical issues (e.g. non-uniform baselines and higher noise associated with higher baseline), but are substantially noisier. As a result, new preprocessing procedures are required before these spectra can be used for statistical classification. RESULTS: In this study, we introduce novel preprocessing steps that can be used with any mass spectra. These comprise a standardization step and a denoising step. The noise level for each spectrum is determined using only data from that spectrum. Only spectral features that exceed a threshold defined by the noise level are subsequently used for classification. Using this approach, we trained the Random Forest program to classify 240 mass spectra into four bacterial types. The method resulted in zero prediction errors in the training samples and in two test datasets having 240 and 300 spectra, respectively.

Algorithms↗

Measurement of toxaphene congeners in pooled human serum collected in three U.S. cities using high-resolution mass spectrometry.

Because human toxaphene exposure data are largely lacking, we surveyed human serum pools collected from U.S. residents to determine the feasibility of measuring toxaphene in human samples and to determine whether additional analytical requirements were needed for routine measurement of toxaphene. We report a method for quantification of toxaphene congeners in human serum using a mixed-bed gradient solid-phase extraction and analysis using gas chromatography-high-resolution mass spectrometry with electron-impact ionization. In this method, we monitored low-mass fragment ions that were common to all 22 congeners. To verify the specific congeners detected, we further analyzed the extract using negative methane chemical ionization. We used this method to measure two specific congeners, Parlar 26 and 50, at concentrations ranging from about 3 to 30 pg/ml (0.7-7 ng/g lipid) in pooled human serum collected in Atlanta, Chicago, and Cincinnati. We identified several analytical parameters that must be strengthened to routinely measure toxaphene congeners in human samples.

Environmental Monitoring↗

Human consumption of methyleugenol and its elimination from serum.

Under a mandate from the U.S. Congress, the National Toxicology Program (NTP) of the U.S. Department of Health and Human Services conducts animal bioassays for carcinogenicity of potentially toxic chemicals to which the U.S. population might be exposed. Methyleugenol, a natural as well as synthesized substance, was nominated for study because it is structurally similar to safrole, a known animal carcinogen. Methyleugenol was found to be a very potent multisite carcinogen in male and female F344/N rats and B6C3F1 mice at all doses tested in 2-year NTP bioassays using gavage dosing. For this reason, human toxicokinetic studies were added to the traditional NTP protocol. A commercial brand of gingersnaps was found by chemists at the Centers for Disease Control and Prevention to contain a relatively high concentration of methyleugenol. After thorough scientific and clinical review, and approval by a National Institutes of Health institutional review board for the protection of human subjects, a study was conducted with nine healthy adult male and female human volunteers. The volunteers were given 12 gingersnaps for breakfast. Blood was drawn immediately before the meal and at 15, 30, 60, and 120 min afterward. The mean +/- SD fasting level of methyleugenol in serum was 16.2 +/- 4.0 pg/g wet weight. Peak blood levels were found at 15 min (mean +/- SD, 53.9 +/- 7.3 pg/g wet weight), followed by a rapid decline; the half-life of elimination was about 90 min. The peak levels were within the range of methyleugenol blood levels in the U.S. population, as measured concurrently in a subset of nonfasting participants in the Third National Health and Nutrition Examination Survey (NHANES III).

Administration, Oral↗

IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study.

BACKGROUND: The national programs for the harmonization of hemoglobin (Hb)A(1c) measurements in the US [National Glycohemoglobin Standardization Program (NGSP)], Japan [Japanese Diabetes Society (JDS)/Japanese Society of Clinical Chemistry (JSCC)], and Sweden are based on different designated comparison methods (DCMs). The future basis for international standardization will be the reference system developed by the IFCC Working Group on HbA(1c) Standardization. The aim of the present study was to determine the relationships between the IFCC Reference Method (RM) and the DCMs. METHODS: Four method-comparison studies were performed in 2001-2003. In each study five to eight pooled blood samples were measured by 11 reference laboratories of the IFCC Network of Reference Laboratories, 9 Secondary Reference Laboratories of the NGSP, 3 reference laboratories of the JDS/JSCC program, and a Swedish reference laboratory. Regression equations were determined for the relationship between the IFCC RM and each of the DCMs. RESULTS: Significant differences were observed between the HbA(1c) results of the IFCC RM and those of the DCMs. Significant differences were also demonstrated between the three DCMs. However, in all cases the relationship of the DCMs with the RM were linear. There were no statistically significant differences between the regression equations calculated for each of the four studies; therefore, the results could be combined. The relationship is described by the following regression equations: NGSP-HbA(1c) = 0.915(IFCC-HbA(1c)) + 2.15% (r(2) = 0.998); JDS/JSCC-HbA(1c) = 0.927(IFCC-HbA(1c)) + 1.73% (r(2) = 0.997); Swedish-HbA(1c) = 0.989(IFCC-HbA(1c)) + 0.88% (r(2) = 0.996). CONCLUSION: There is a firm and reproducible link between the IFCC RM and DCM HbA(1c) values.

Blood Chemical Analysis↗

Analysis of recombinant acylated pneumococcal surface adhesin A of Streptococcus pneumoniae by mass spectrometry.

Streptococcus pneumoniae pneumococcal surface adhesin A (PsaA) is a species-common, immunogenic surface lipoprotein. In this study, the psaA gene was expressed as a nonfusion acylated protein in an Escherichia coli expression system. Yields of pure recombinant PsaA (rPsaA) were 8-10 mg/liter of fermentation culture. Analysis of rPsaA tryptic digests by HPLC-electrospray mass spectrometry (MS) confirmed 98% of the expected protein sequence. GC/MS data demonstrated very similar acylation of native and rPsaA by C12:0-C22:0 fatty acids, with C16 and C18 predominating. Negative ion electrospray MS/MS analysis of the rPsaA lipid anchor released by Pronase-E confirmed that the structure was based on an N-terminal palmitoylcysteine (Pam(3)Cys). Electrospray MS heterogeneity analysis of intact rPsaA indicated that all of the observed heterogeneity could be accounted for by the fatty acid distributions. The availability of well-characterized rPsaA will facilitate the continued research and development of protein-based vaccines for the prevention of pneumococcal disease.

Adhesins, Bacterial↗

New high-resolution mass spectrometric approach for the measurement of polychlorinated biphenyls and organochlorine pesticides in human serum.

To increase our analytical throughput for measuring polychlorinated biphenyls (PCBs) and organochlorine (OC) pesticides without sacrificing data quality, we have developed and validated a combined PCB/OC pesticide gas chromatography-high-resolution mass spectrometry (GC-HRMS) analysis. In a single GC-HRMS analysis, both selected PCBs and OC pesticides are detected and quantified. Previously, this has been difficult, if not impossible, because of the major difference in masses of the most abundant electron-impact ions. However, we have identified slightly less abundant ions to monitor that allow us to successfully combine these analytes into a single analysis without sacrificing any analytical sensitivity or instrument reliability. Consequently, we have been able to double our analytical throughput by modification of mass spectrometric parameters alone. Our new methodology has been validated against our current GC-HRMS method, which entails using two separate injections, one for PCB analysis and one for OC pesticide analysis. The two methods differ by less than 4% overall, with no systematic bias. We used this method to analyze approximately 350 serum samples over a period of several months. We found that our new method was as reliable in automated, overnight runs as our current method.

Gas Chromatography-Mass Spectrometry↗

Comprehensive solid-phase extraction method for persistent organic pollutants. Validation and application to the analysis of persistent chlorinated pesticides.

The Centers for Disease Control and Prevention (CDC) is involved in many epidemiological studies regarding the measurement of chlorinated pesticides and polychlorinated biphenyls in specimens obtained from humans. In addition to these commonly determined analytes, there is a need to include additional persistent organic pollutants (POPs) in our analyses, which further stresses the analyses because sample volumes remain small. Thus, a single method of analysis for all POPs in human serum is needed. CDC has recently developed a semiautomated and comprehensive solid-phase extraction method for POPs. The method is comprehensive since it was optimized for the extraction of many different POP compound classes. We then developed a purification and fractionation scheme that allows (a) separation of different compound classes by particular functionalities and (b) purification of those fractions to remove coextracted interferences. This paper describes the first step in the semiautomated comprehensive extraction and multiple fractionation method developed by CDC for monitoring POPs. In this paper, we validate the analysis of the persistent chlorinated pesticides, a compound class difficult to examine because of their structural diversity, in human plasma. The method was validated against an existing CDC method by using a spiked quality-control serum pool. The concentrations determined for all analytes using both methods were within 2%-14% relative standard deviations. A multilevel (i.e., 3-4 point) matrix spike showed good linearity for the analytes tested (r2 = 0.978-0.999). The method was then applied to 40-year-old archived plasma samples for the quantitative analysis of selected chlorinated pesticides. Mean recoveries of the 13C-labeled internal quantification standards ranged from 64% to 123% for the 11 monitored pesticides. The overall method proved to be robust by handling old coagulated plasma samples. It allowed faster throughput of samples than our previous methods and provided cleaner samples with less frequent interferences or background as analyzed by high-resolution mass spectrometry. The method represents a preliminary step in establishing an automated, comprehensive multiresidue analysis method for POPs in human serum.

Automation↗

Contemporary-use pesticides in personal air samples during pregnancy and blood samples at delivery among urban minority mothers and newborns.

We have measured 29 pesticides in plasma samples collected at birth between 1998 and 2001 from 230 mother and newborn pairs enrolled in the Columbia Center for Children's Environmental Health prospective cohort study. Our prior research has shown widespread pesticide use during pregnancy among this urban minority cohort from New York City. We also measured eight pesticides in 48-hr personal air samples collected from the mothers during pregnancy. The following seven pesticides were detected in 48-83% of plasma samples (range, 1-270 pg/g): the organophosphates chlorpyrifos and diazinon, the carbamates bendiocarb and 2-isopropoxyphenol (metabolite of propoxur), and the fungicides dicloran, phthalimide (metabolite of folpet and captan), and tetrahydrophthalimide (metabolite of captan and captafol). Maternal and cord plasma levels were similar and, except for phthalimide, were highly correlated (p < 0.001). Chlorpyrifos, diazinon, and propoxur were detected in 100% of personal air samples (range, 0.7-6,010 ng/m(3)). Diazinon and propoxur levels were significantly higher in the personal air of women reporting use of an exterminator, can sprays, and/or pest bombs during pregnancy compared with women reporting no pesticide use or use of lower toxicity methods only. A significant correlation was seen between personal air level of chlorpyrifos, diazinon, and propoxur and levels of these insecticides or their metabolites in plasma samples (maternal and/or cord, p < 0.05). The fungicide ortho-phenylphenol was also detected in 100% of air samples but was not measured in plasma. The remaining 22 pesticides were detected in 0-45% of air or plasma samples. Chlorpyrifos, diazinon, propoxur, and bendiocarb levels in air and/or plasma decreased significantly between 1998 and 2001. Findings indicate that pesticide exposures are frequent but decreasing and that the pesticides are readily transferred to the developing fetus during pregnancy.

Adult↗

A multi-analyte method for the quantification of contemporary pesticides in human serum and plasma using high-resolution mass spectrometry.

We have developed a sensitive and accurate analytical method for quantifying 29 contemporary pesticides in human serum or plasma. These pesticides include organophosphates, carbamates, chloroacetanilides, and synthetic pyrethroids among others and include pesticides used in agricultural and residential settings. Our method employs a simple solid-phase extraction followed by a highly selective analysis using isotope dilution gas chromatography-high-resolution mass spectrometry. Our method is very accurate, has limits of detection in the low pg/g range and coefficients of variation of typically less than 20% at the low pg/g end of the method linear range. We have used this method to measure plasma pesticide concentrations in females living in an urban area. We found detectable concentrations of carbaryl/naphthalene, propoxur, bendiocarb, chlorpyrifos, diazinon, dicloran, captan and folpet or their metabolites in more than 20% of the plasma samples tested.

Calibration↗