PubMed Health⌕ Search

PubMed · 12530820

Comprehensive solid-phase extraction method for persistent organic pollutants. Validation and application to the analysis of persistent chlorinated pesticides.

Abstract

The Centers for Disease Control and Prevention (CDC) is involved in many epidemiological studies regarding the measurement of chlorinated pesticides and polychlorinated biphenyls in specimens obtained from humans. In addition to these commonly determined analytes, there is a need to include additional persistent organic pollutants (POPs) in our analyses, which further stresses the analyses because sample volumes remain small. Thus, a single method of analysis for all POPs in human serum is needed. CDC has recently developed a semiautomated and comprehensive solid-phase extraction method for POPs. The method is comprehensive since it was optimized for the extraction of many different POP compound classes. We then developed a purification and fractionation scheme that allows (a) separation of different compound classes by particular functionalities and (b) purification of those fractions to remove coextracted interferences. This paper describes the first step in the semiautomated comprehensive extraction and multiple fractionation method developed by CDC for monitoring POPs. In this paper, we validate the analysis of the persistent chlorinated pesticides, a compound class difficult to examine because of their structural diversity, in human plasma. The method was validated against an existing CDC method by using a spiked quality-control serum pool. The concentrations determined for all analytes using both methods were within 2%-14% relative standard deviations. A multilevel (i.e., 3-4 point) matrix spike showed good linearity for the analytes tested (r2 = 0.978-0.999). The method was then applied to 40-year-old archived plasma samples for the quantitative analysis of selected chlorinated pesticides. Mean recoveries of the 13C-labeled internal quantification standards ranged from 64% to 123% for the 11 monitored pesticides. The overall method proved to be robust by handling old coagulated plasma samples. It allowed faster throughput of samples than our previous methods and provided cleaner samples with less frequent interferences or background as analyzed by high-resolution mass spectrometry. The method represents a preliminary step in establishing an automated, comprehensive multiresidue analysis method for POPs in human serum.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Courtney D Sandau, Andreas Sjödin, Mark D Davis, John R Barr, Vincent L Maggio, Alyson L Waterman, Kerry E Preston, James L Preau, Dana B Barr, Larry L Needham, Donald G Patterson. 2003-01-01. Comprehensive solid-phase extraction method for persistent organic pollutants. Validation and application to the analysis of persistent chlorinated pesticides.. https://doi.org/10.1021/ac026121u. https://pubmed.health/record/pubmed%3A12530820/comprehensive-solid-phase-extraction-method-for-persistent-organic-pollutants-validation-and-applica

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Characteristics of the m2000 automated sample preparation and multiplex real-time PCR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

We evaluated a new real-time PCR-based prototype assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae developed by Abbott Molecular Inc. This assay is designed to be performed on an Abbott m2000 real-time instrument system, which consists of an m2000sp instrument for sample preparation and an m2000rt instrument for real-time PCR amplification and detection. The limit of detection of this prototype assay was determined to be 20 copies of target DNA for both C. trachomatis and N. gonorrhoeae, using serially diluted linearized plasmids. No cross-reactivity could be detected when 55 nongonococcal Neisseria isolates and 3 non-C. trachomatis Chlamydia isolates were tested at 1 million genome equivalents per reaction. Concordance with the Roche Amplicor, BDProbeTec ET, and Gen-Probe APTIMA Combo 2 tests was assessed using unlinked/deidentified surplus clinical specimens previously analyzed with these tests. For C. trachomatis, concordance for positive results ranged from 93.7% to 100%, while concordance for negative results ranged from 98.2% to 100%. For N. gonorrhoeae, concordance for positive and negative results ranged from 91.4% to 100% and 99.3% to 100%, respectively. A workflow analysis of the prototype assay was conducted to obtain information on throughput under laboratory conditions. At 48 samples/run, the time to first result for both C. trachomatis and N. gonorrhoeae was 4.5 h. A total of 135 patient specimens could be analyzed in 8.9 h, with 75 min of hands-on time. This study demonstrated the technical and clinical feasibility of the new Abbott real-time PCR C. trachomatis/N. gonorrhoeae assay.

Automation↗

Pronase-immobilized enzyme reactor: an approach for automation in glycoprotein analysis by LC/LC-ESI/MSn.

An automated analytical approach is proposed for simultaneous characterization of glycan and peptide moieties in pronase-generated glycopeptides. The proposed method is based on the use of a new pronase-immobilized enzyme reactor for the on-line rapid digestion of the target glycoprotein. By coupling the bioreactor to a Hypercarb chromatographic trap column, on-line selective glycopeptide enrichment prior to normal-phase liquid chromatography-mass spectrometry was obtained. A detailed study was carried out for integration and automation of each phase of the proposed analytical procedure. On-line digestion allowed extensive cleavage of the model protein (ribonuclease B), yielding to glycopeptides with peptide moieties up to eight amino acids, carrying the Man5-Man9 N-glycans each, selectively resolved on an Amide-80 column. The use of a linear ion trap instrument resulted in efficient ion capture and led to MS3 acquisition times and spectra quality similar to those for MS2, allowing the unambiguous identification of glycan (MS2) and peptide (MS3) sequences. The proposed procedure reduces the glycoprotein analysis time from approximately 3 days, as in most of the traditional off-line methods, to approximately 1 h.

Automation↗

An improved high-throughput liquid chromatographic/tandem mass spectrometric method for terbinafine quantification in human plasma, using automated liquid-liquid extraction based on 96-well format plates.

A fully automated high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for terbinafine quantification in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 2.2 mL 96-deepwell plates. Terbinafine and the internal standard (IS) N-methyl-1-naphthalenemethylamine were extracted from human plasma by LLE, using a mixture of methyl t-butyl ether (MTBE)-hexane (70:30, v/v) as the organic solvent. All liquid transfer steps, including preparation of calibration standards and quality control samples, as well as the addition of the IS, were performed automatically by using robotic liquid handling workstations. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated and reconstituted in a small volume of a reconstitution solution. Sample analysis was performed by reversed-phase LC-MS/MS, with positive ion electrospray ionization, using multiple reaction monitoring (MRM). The method had a very short sample preparation time and a chromatographic run time of 2.2 min. It was proved to have excellent sensitivity, specificity, accuracy as well as inter- and intraday precision for the quantification of terbinafine in human plasma. The calibration curve was linear for the range of concentrations 5.0-2000.0 ng/mL. The proposed method was applied to the rapid and reliable determination of terbinafine in a bioequivalence study after per os administration of 250 mg tablet formulations of terbinafine.

Automation↗