Control methods for mineral oil mists.

Effective mist collection is important, but it is not the only determinant of mist concentration in plant air. Oil-based metalworking fluids such as straight and soluble oils contain semivolatile hydrocarbons. When these fluids form a mist, their semivolatile components partition between the vapor and mist phases depending on the makeup of the mist and on local conditions. This article addresses the relationship between the concentrations of semivolatile hydrocarbons in the vapor and mist phases using theory for partitioning developed in the field of atmospheric chemistry. Mist can be removed effectively in a collector that uses a HEPA filter as its final collection stage. Acceptable HEPA lifetime requires effective upstream stages that reduce mist loading to the HEPA; furthermore, acceptable HEPA performance requires that it be installed and maintained properly. Collectors designed to remove mist do not remove vapor, and as collector exhaust mixes into cooler plant air that already contains some mist, vapor from the collector can repartition to increase the mist concentration in the plant. Assessing the effect of vapor-to-mist repartitioning is complicated; however, repartitioning may be important for many of the compounds contained in oil-based metalworking fluids. Conditions that minimize vapor-to-mist repartitioning, such as ventilating the plant with clean outdoor air, increasing plant temperature, or controlling the release of vapor, may also be expensive, uncomfortable to plant occupants, or impractical from an engineering standpoint. As a result, very low mist concentrations in plant air may be difficult to attain.

Air Pollutants, Occupational↗

Partitioning theory for respiratory deposition of semivolatile aerosols.

The objective of this work is to model the deposition of semivolatile aerosols in the lungs based on gas-particle and tissue-air partitioning theory. Semivolatile compounds exist in air as both particles and gases simultaneously. Mass distributes between the two phases according to a gas-particle partitioning ratio, R(pg) = K(p)(TSP). Particle deposition in the lungs is a function of aerodynamic diameter, whereas gas deposition is a function of tissue solubility, which is related to the air-lung partitioning ratio, K(la). Therefore, deposition to the lungs will vary with R(pg) and K(la). These and other parameters determine a dimensionless deposition number, D, which indicates whether particles or gases are most responsible for deposition of semivolatile chemicals in the lung. The deposition number allows industrial hygienists to design effective air sampling strategies and control measures that will minimize risks associated with exposure to semivolatiles. Examples of deposition numbers for common semivolatile pollutants are provided, including alkanes, polycyclic aromatic hydrocarbons, pesticides and polychlorinated biphenyls.

Aerosols↗

Electrostatic sampler for semivolatile aerosols: chemical artifacts.

Electrostatic precipitators (ESPs) show promise as an alternative sampling method for semivolatile aerosols because they are less susceptible to adsorptive and evaporative artifacts than filter based methods. However, the corona discharge may after the chemical composition of a sampled aerosol. Chemical artifacts associated with electrostatic precipitation of semivolatile aerosols were investigated in the laboratory. ESPs and filters sampled both particles and vapors of alkanes, polycyclic aromatic hydrocarbons, and alkenes across varying concentrations. Gravimetric measurements between the two sampling methods were well correlated. Ozone generated by the ESP corona was the primary cause of alkene reactions in the gas phase. Particles collected within the corona region were vulnerable to irradiation by corona ions overtime. Particles collected outside the corona region did not react. Vapors passing through the corona reacted to a lesser extent. Vapors captured after passing through the ESP reacted with ozone that was not removed by the vapor trap. Chemical speciation of highly reactive compounds (i.e., alkenes or other compounds with relatively short half-lives outdoors) is not appropriate with ESPs. Electrostatic precipitation of these compounds is appropriate, however, when total organic carbon is of interest as the ESP does not alter the amount of mass measured gravimetrically. ESPs can make accurate measurements of more persistent semivolatile compounds, such as alkanes and PAHs.

Aerosols↗

Filter and electrostatic samplers for semivolatile aerosols: physical artifacts.

Adsorptive and evaporative artifacts often bias measurements of semivolatile aerosols. Adsorption occurs when the sampling method disrupts the gas-particle partitioning equilibrium. Evaporation occurs because concentrations of semivolatiles are rarely constant over time. Filtration is subject to both adsorptive and evaporative artifacts. By comparison, electrostatic precipitation reduces these artifacts by minimizing the surface area of collected particles without substantially disrupting the gas-particle equilibrium. The extent of these artifacts was determined for filter samplers and electrostatic precipitator samplers for semivolatile alkane aerosols in the laboratory. Adsorption of gas-phase semivolatiles was lower in electrostatic precipitators by factors of 5-100 compared to the filter method. Particle evaporation from the electrostatic sampler was 2.3 times lower than that from TFE-coated glass-fiber filters. Use of a backup filter to correct for compound-specific adsorption artifacts can introduce positive or negative errors to the measured particle-phase concentration due to competition among the adsorbates for available adsorption sites. Adsorption of evaporated particles from the front filter onto the backup filter increased the measured evaporative artifact by a factor of 1.5-2.

Adsorption↗