Control methods for mineral oil mists.

Abstract

Effective mist collection is important, but it is not the only determinant of mist concentration in plant air. Oil-based metalworking fluids such as straight and soluble oils contain semivolatile hydrocarbons. When these fluids form a mist, their semivolatile components partition between the vapor and mist phases depending on the makeup of the mist and on local conditions. This article addresses the relationship between the concentrations of semivolatile hydrocarbons in the vapor and mist phases using theory for partitioning developed in the field of atmospheric chemistry. Mist can be removed effectively in a collector that uses a HEPA filter as its final collection stage. Acceptable HEPA lifetime requires effective upstream stages that reduce mist loading to the HEPA; furthermore, acceptable HEPA performance requires that it be installed and maintained properly. Collectors designed to remove mist do not remove vapor, and as collector exhaust mixes into cooler plant air that already contains some mist, vapor from the collector can repartition to increase the mist concentration in the plant. Assessing the effect of vapor-to-mist repartitioning is complicated; however, repartitioning may be important for many of the compounds contained in oil-based metalworking fluids. Conditions that minimize vapor-to-mist repartitioning, such as ventilating the plant with clean outdoor air, increasing plant temperature, or controlling the release of vapor, may also be expensive, uncomfortable to plant occupants, or impractical from an engineering standpoint. As a result, very low mist concentrations in plant air may be difficult to attain.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

David Leith, John Volckens, Maryanne G Boundy, David Hands. 2003. Control methods for mineral oil mists.. https://doi.org/10.1080/10473220390237412

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Exposure to mercury in the mine of Almaden.

OBJECTIVES: To describe the process for obtaining mercury and the historical exposure of Almadén miners to mercury. METHODS: Information on every workplace and historical data on production, technological changes in the productive process and biological and environmental values of mercury was collected. A job-exposure matrix was built with these values and the exposure to inorganic mercury was estimated quantitatively as mug/l of urine mercury. A cumulative exposure index was calculated for every worker by adding the estimates for every year in the different workplaces. RESULTS: In the mine, the highest exposures occurred during drilling, with values up to 2.26 mg/m3 in air, 2194 microg/l in urine and 374 microg/l in blood. Furnace operation and cleaning were the tasks with the highest values in metallurgy, peaking up to 3.37 mg/m3. The filling of bottles with mercury by free fall gave values within a range of 1.13-2.43 mg/m3 in air; these values dropped to 0.32-0.83 mg/m3 after introducing a new ventilation system. The toxicity effects of high doses of inorganic mercury on the central nervous and urinary systems have been known for decades. CONCLUSIONS: The exposure of the workers in Almadén mines to mercury has been very high. The extremely high content cinnabar ore of the mine explains the increased concentrations of mercury in air at the work places. This, together with inadequate working conditions, explains the high mercury levels found in blood and urine during the study period.

Air Pollutants, Occupational↗

Influence of start-up on PCDD/F emission of incinerators.

This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.

Air Pollutants, Occupational↗