PubMed Health⌕ Search

Biomedical subjects

Jr-Lung Lin

Publications and source records attributed to Jr-Lung Lin.

3 recordsLinked to original sources

Model description of contact angles in electrowetting on dielectric layers.

The electrowetting on dielectric (EWOD) technique has considerable potential for microfluidic and biomedical applications. The Lippmann-Young model based on the force balance concept has long been used to predict the contact angles of droplets under electrowetting. However, recent experimental evidence has indicated that this model fails to provide accurate predictions of the lower contact angles associated with saturation conditions at higher electric potentials. Hence, the study simulates the internal flow in an actuated droplet and treats it as stagnation-point flow. This kinetic energy is then taken into consideration while calculating the contact angles using an energy balance model. The energy of an actuated droplet is contributed by the combination of the side surface tension energy, the base tension energy, the dielectric energy, and the kinetic energy when deriving the energy balance model. Consequently, the new energy balance model modifies the Lippmann-Young equation, thereby providing enhanced reasonable predictions of the droplet contact angle across the higher electric potential where the contact angles are close to the saturated condition.

Journal Article↗

Integrated polymerase chain reaction chips utilizing digital microfluidics.

This study reports an integrated microfluidic chip for polymerase chain reaction (PCR) applications utilizing digital microfluidic chip (DMC) technology. Several crucial procedures including sample transportation, mixing, and DNA amplification were performed on the integrated chip using electro-wetting-on-dielectric (EWOD) effect. An innovative concept of hydrophobic/hydrophilic structure has been successfully demonstrated to integrate the DMC chip with the on-chip PCR device. Sample droplets were generated, transported and mixed by the EWOD-actuation. Then the mixture droplets were transported to a PCR chamber by utilizing the hydrophilic/hydrophobic interface to generate required surface tension gradient. A micro temperature sensor and two micro heaters inside the PCR chamber along with a controller were used to form a micro temperature control module, which could perform precise PCR thermal cycling for DNA amplification. In order to demonstrate the performance of the integrated DMC/PCR chips, a detection gene for Dengue II virus was successfully amplified and detected. The new integrated DMC/PCR chips only required an operation voltage of 12V(RMS) at a frequency of 3 KHz for digital microfluidic actuation and 9V(DC) for thermal cycling. When compared to its large-scale counterparts for DNA amplification, the developed system consumed less sample and reagent and could reduce the detection time. The developed chips successfully demonstrated the feasibility of Lab-On-a-Chip (LOC) by utilizing EWOD-based digital microfluidics.

Dengue Virus↗

Active mixing inside microchannels utilizing dynamic variation of gradient zeta potentials.

This study presents a new active micromixer with high mixing efficiency achieved by means of a gradient distribution of the surface zeta potential controlled by changing the frequency of voltage applied on shielding electrodes. Gradient surface zeta potential is generated by applying a high voltage to inclined buried shielding electrodes. While alternating the frequency of driving voltage, the zeta potential could be changed accordingly, thus providing a significant mixing effect inside microchannels. A theoretical model is proposed to predict the distribution of zeta potential. The results from this model are critically compared with the well-developed three-capacitor model. Additionally, two time-factor scales, the charge time of capacitor and mixing length flow time, are used to predict the optimum frequency. The prediction of optimum frequency, 0.5 Hz, is consistent with experimental results. Moreover, a five-pair inclined shielding electrode with a frequency of 0.5 Hz leads to a significant improvement in the mixing performance of the active micromixer. Numerical results indicate that a localized flow circulation is generated when the control voltage is applied to the inclined shielding electrodes. Furthermore, the streamlines are experimentally observed by using fluorescent beads. The shape of this circulation is dependent on the distribution of gradient zeta potential, which is determined by the arrangement of electrodes. The effects of the number of electrode pairs and the layout of shielding electrodes on the mixing performance of micromixer are also explored both numerically and experimentally. It is revealed that five-pair inclined electrodes at 0.5 Hz provide the highest mixing efficiency. Finally, a reaction between N-benzoyl-L-arginine-p-nitroanilide and trypsin enzyme is performed to verify the capability of micromixers. The experimental results reveal that the reaction can achieve a higher performance indicating a higher mixing efficiency. The active micromixers could be used in microfluidic systems for improving the mixing efficiency and thus enhancing the bioreaction.

Electrophoresis, Microchip↗