Active mixing inside microchannels utilizing dynamic variation of gradient zeta potentials.

Abstract

This study presents a new active micromixer with high mixing efficiency achieved by means of a gradient distribution of the surface zeta potential controlled by changing the frequency of voltage applied on shielding electrodes. Gradient surface zeta potential is generated by applying a high voltage to inclined buried shielding electrodes. While alternating the frequency of driving voltage, the zeta potential could be changed accordingly, thus providing a significant mixing effect inside microchannels. A theoretical model is proposed to predict the distribution of zeta potential. The results from this model are critically compared with the well-developed three-capacitor model. Additionally, two time-factor scales, the charge time of capacitor and mixing length flow time, are used to predict the optimum frequency. The prediction of optimum frequency, 0.5 Hz, is consistent with experimental results. Moreover, a five-pair inclined shielding electrode with a frequency of 0.5 Hz leads to a significant improvement in the mixing performance of the active micromixer. Numerical results indicate that a localized flow circulation is generated when the control voltage is applied to the inclined shielding electrodes. Furthermore, the streamlines are experimentally observed by using fluorescent beads. The shape of this circulation is dependent on the distribution of gradient zeta potential, which is determined by the arrangement of electrodes. The effects of the number of electrode pairs and the layout of shielding electrodes on the mixing performance of micromixer are also explored both numerically and experimentally. It is revealed that five-pair inclined electrodes at 0.5 Hz provide the highest mixing efficiency. Finally, a reaction between N-benzoyl-L-arginine-p-nitroanilide and trypsin enzyme is performed to verify the capability of micromixers. The experimental results reveal that the reaction can achieve a higher performance indicating a higher mixing efficiency. The active micromixers could be used in microfluidic systems for improving the mixing efficiency and thus enhancing the bioreaction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jr-Lung Lin, Kuo-Hoong Lee, Gwo-Bin Lee. 2005. Active mixing inside microchannels utilizing dynamic variation of gradient zeta potentials.. https://doi.org/10.1002/elps.200500402

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrasonic standing wave manipulation technology integrated into a dielectrophoretic chip.

Several cell-based biological applications in microfluidic systems require simultaneous high-throughput and individual handling of cells or other bioparticles. Available chip-based tools for contactless manipulation are designed for either high-precision handling of individual particles, or high-throughput handling of ensembles of particles. In order to simultaneously perform both, we have combined two manipulation technologies based on ultrasonic standing waves (USWs) and dielectrophoresis (DEP) in a microfluidic chip. The principle is based on the competition between long-range ultrasonic forces, short-range dielectrophoretic forces and viscous drag forces from the fluid flow. The ultrasound is coupled into the microchannel resonator by an external transducer with a refractive element placed on top of the chip, thereby allowing transmission light microscopy to continuously monitor the biological process. The DEP manipulation is generated by an electric field between co-planar microelectrodes placed on the bottom surface of the fluid channel. We demonstrate flexible and gentle elementary manipulation functions by the use of USWs and linear or curved DEP deflector elements that can be used in high-throughput biotechnology applications of individual cells.

Electrophoresis, Microchip↗

Rapid on-column analysis of glucosamine and its mutarotation by microchip capillary electrophoresis.

A novel electrophoretic microchip method for analyzing alpha- and beta-d-glucosamine and their interconversion in solution is presented. d-Glucosamine is labeled with fluorescamine and analyzed by capillary electrophoresis in under 2 min revealing its pH-dependent mutarotation between the alpha- and beta-anomers. The forward interconversion rates for the labeled sugars, based on an iterative analysis of the plateau heights between the peaks, are 0.72+/-0.09, 1.3+/-0.1, and 2.2+/-0.3 x 10(-3)s(-1) at pH 8.99, 9.51 and 10.01, respectively. In a separate experiment, the mutarotation of the unlabeled alpha-d-anomer was followed; the relative intensities of the alpha- and beta-peaks as a function of reaction time at pH 9.51 give a forward rate constant of 0.6+/-0.1 x 10(-3)s(-1). These results demonstrate that fast microchip separations, previously exploited for amine, amino acid, and nucleobase analysis, can also be used to analyze amino sugars and their mutarotation.

Electrophoresis, Microchip↗

Dielectrophoresis field flow fractionation of single-walled carbon nanotubes.

We report a study on Dielectrophoresis Field Flow Fractionation of Single-Wall Carbon Nanotubes (SWNTs). SWNTs, individually suspended in 1% SDBS solution, were separated by type when they passed a dielectrophoresis field flow fractionation device where 1 MHz AC voltage was supplied and the field strength was well below 1 V per mum. Furthermore, we uniquely observed enrichment of semiconductive SWNTs based on their band gap. In addition to Raman spectrum, UV-vis absorption and NIR fluorescence spectra were used for solution samples for characterization.

Electrophoresis, Microchip↗