PubMed Health⌕ Search

Biomedical subjects

Jules H Sumkin

Publications and source records attributed to Jules H Sumkin.

At least 19 recordsLinked to original sources

Prospective screening study of 0.5 Tesla dedicated magnetic resonance imaging for the detection of breast cancer in young, high-risk women.

BACKGROUND: Evidence-based screening guidelines are needed for women under 40 with a family history of breast cancer, a BRCA1 or BRCA2 mutation, or other risk factors. An accurate assessment of breast cancer risk is required to balance the benefits and risks of surveillance, yet published studies have used narrow risk assessment schemata for enrollment. Breast density limits the sensitivity of film-screen mammography but is not thought to pose a limitation to MRI, however the utility of MRI surveillance has not been specifically examined before in women with dense breasts. Also, all MRI surveillance studies yet reported have used high strength magnets that may not be practical for dedicated imaging in many breast centers. Medium strength 0.5 Tesla MRI may provide an alternative economic option for surveillance. METHODS: We conducted a prospective, nonrandomized pilot study of 30 women age 25-49 years with dense breasts evaluating the addition of 0.5 Tesla MRI to conventional screening. All participants had a high quantitative breast cancer risk, defined as > or = 3.5% over the next 5 years per the Gail or BRCAPRO models, and/or a known BRCA1 or BRCA2 germline mutation. RESULTS: The average age at enrollment was 41.4 years and the average 5-year risk was 4.8%. Twenty-two subjects had BIRADS category 1 or 2 breast MRIs (negative or probably benign), whereas no category 4 or 5 MRIs (possibly or probably malignant) were observed. Eight subjects had BIRADS 3 results, identifying lesions that were "probably benign", yet prompting further evaluation. One of these subjects was diagnosed with a stage T1aN0M0 invasive ductal carcinoma, and later determined to be a BRCA1 mutation carrier. CONCLUSION: Using medium-strength MRI we were able to detect 1 early breast tumor that was mammographically undetectable among 30 young high-risk women with dense breasts. These results support the concept that breast MRI can enhance surveillance for young high-risk women with dense breasts, and further suggest that a medium-strength instrument is sufficient for this application. For the first time, we demonstrate the use of quantitative breast cancer risk assessment via a combination of the Gail and BRCAPRO models for enrollment in a screening trial.

Journal Article↗

A multisite telemammography system for remote management of screening mammography: an assessment of technical, operational, and clinical issues.

OBJECTIVE: This paper describes a high-quality, multisite telemammography system to enable "almost real-time" remote patient management while the patient remains in the clinic. One goal is to reduce the number of women who would physically need to return to the clinic for additional imaging procedures (termed "recall") to supplement "routine" imaging of screening mammography. MATERIALS AND METHODS: Mammography films from current and prior (when available) examinations are digitized at three remote sites and transmitted along with other pertinent information across low-level communication systems to the central site. Images are automatically cropped, wavelet compressed, and encrypted prior to transmission to the central site. At the central site, radiologists review and rate examinations on a high-resolution workstation that displays the images, computer-assisted detection results, and the technologist's communication. Intersite communication is provided instantly via a messaging "chat" window. RESULTS: The technologists recommended additional procedures at 2.7 times the actual clinical recall rate for the same cases. Using the telemammography system during a series of "off-line" clinically simulated studies, radiologists recommended additional procedures at 1.3 times the actual clinical recall rate. Percent agreement and kappa between the study and actual clinical interpretations were 66.1% and 0.315, respectively. For every physical recall potentially avoided using the telemammography system, approximately one presumed "unnecessary" imaging procedure was recommended. CONCLUSION: Remote patient management can reduce the number of women recalled by as much as 50% without performing an unreasonable number of presumed "unnecessary" procedures.

Ambulatory Care Facilities↗

A method to improve visual similarity of breast masses for an interactive computer-aided diagnosis environment.

The purpose of this study was to develop and test a method for selecting "visually similar" regions of interest depicting breast masses from a reference library to be used in an interactive computer-aided diagnosis (CAD) environment. A reference library including 1000 malignant mass regions and 2000 benign and CAD-generated false-positive regions was established. When a suspicious mass region is identified, the scheme segments the region and searches for similar regions from the reference library using a multifeature based k-nearest neighbor (KNN) algorithm. To improve selection of reference images, we added an interactive step. All actual masses in the reference library were subjectively rated on a scale from 1 to 9 as to their "visual margins speculations". When an observer identifies a suspected mass region during a case interpretation he/she first rates the margins and the computerized search is then limited only to regions rated as having similar levels of spiculation (within +/-1 scale difference). In an observer preference study including 85 test regions, two sets of the six "similar" reference regions selected by the KNN with and without the interactive step were displayed side by side with each test region. Four radiologists and five nonclinician observers selected the more appropriate ("similar") reference set in a two alternative forced choice preference experiment. All four radiologists and five nonclinician observers preferred the sets of regions selected by the interactive method with an average frequency of 76.8% and 74.6%, respectively. The overall preference for the interactive method was highly significant (p < 0.001). The study demonstrated that a simple interactive approach that includes subjectively perceived ratings of one feature alone namely, a rating of margin "spiculation," could substantially improve the selection of "visually similar" reference images.

Algorithms↗

Screening mammography: do women prefer a higher recall rate given the possibility of earlier detection of cancer?

PURPOSE: To prospectively survey women undergoing screening mammography to assess their attitudes toward and preference for the level of recall rates given the possibility that an increase in recall rates may result in earlier detection of cancer. MATERIALS AND METHODS: This HIPAA-compliant survey was performed with an institutional review board-approved protocol. Women who arrived for their routine screening mammographic examination from November 2004 to March 2005 were informed before they consented to participate. The distribution of responses for each survey question was summarized, and proportions for the entire group and different subgroups were computed. The z score statistic was used to assess significant differences between subgroups. RESULTS: Fifteen hundred seventy anonymized questionnaires were collected; 1171 (75%) were from women between 40 and 59 years of age. Of 1528 respondents, 1486 (97%) believed that a false-positive result would not deter them from continuing with regular screening, and most would have been willing to be recalled more often for either a noninvasive (86% [1308 of 1519 respondents]) or an invasive (82% [1248 of 1515 respondents]) procedure if it might increase the chance of detecting a cancer (if present) earlier. Compared with respondents undergoing their initial screening mammographic examination, women who had undergone at least one prior screening examination reported that they were more likely to continue with screening if they had received a previous false-positive result (P = .02). Women younger than 60 years and those previously recalled were more willing to be called back more often for a noninvasive or, when indicated, an invasive procedure (P < .05). CONCLUSION: A substantial fraction of women in this study would have preferred the inconvenience of and anxiety associated with a higher recall rate if it resulted in the possibility of detecting breast cancer earlier.

Adult↗

CAD in screening mammography.

OBJECTIVE: The benefit and cost of computer-assisted detection (CAD) mammography screening remains a topic of great interest in breast imaging. Our purpose is to reflect on and interleave two articles in this issue of the AJR that highlight the difficulty in assessing the actual benefit of using CAD from either retrospective or prospective studies. CONCLUSION: This commentary describes the possible benefit and some of the issues associated with the clinical use of current CAD technology while emphasizing the expectation of and need for future improvements in CAD performance.

Breast Neoplasms↗

Trends in recall, biopsy, and positive biopsy rates for screening mammography in an academic practice.

PURPOSE: To retrospectively evaluate whether recall, biopsy, and positive biopsy rates for a group of radiologists who met requirements of Mammography Quality Standards Act of 1992 (MQSA) demonstrated any change over time during a 27-month period (nine consecutive calendar quarters). MATERIALS AND METHODS: Institutional review board approved study protocol, and informed consent was waived. All screening mammograms that had been interpreted by MQSA-qualified radiologists between January 1, 2001, and March 31, 2003, were reviewed. Group recall rates, biopsy rates, and detected cancer rates for nine calendar quarters were computed and attributed to performance date of original screening mammogram. Type of biopsy performed was classified as follows: stereotactic vacuum-assisted biopsy, ultrasonography (US)-guided core biopsy, US-guided fine-needle aspiration biopsy, surgical excision, and multiple biopsies. chi(2) Test for trend (two sided) and linear regression were used to assess trends over time for recall and biopsy rates, biopsy rates according to type of biopsy performed, and percentage of biopsy results positive for cancer. RESULTS: Group recall rate did not show a statistically significant trend during period studied (P = .59). Biopsy rates increased significantly from 13.02 to 20.12 per 1000 screening examinations (P < .001). A corresponding substantial decrease was seen in percentage of biopsies in which malignancy was found, although this trend was not statistically significant (P = .24). A significant increase (from 4.72 to 9.88 per 1000 screening examinations) was found in rate of stereotactic vacuum-assisted 11-gauge core biopsies performed (P < .001). CONCLUSION: Observed increase in biopsy rates reinforces the need to carefully select patients for biopsy to achieve efficient, efficacious, and cost-effective programs for early detection of breast cancers.

Biopsy↗

Stereo CT image compositing methods for lung nodule detection and characterization.

RATIONALE AND OBJECTIVES: Stereographic display has been proposed as a possible method of improving performance in reading computed tomographic (CT) examinations acquired for lung cancer screening. Optimizing such displays is important given the large volume of image data that must be evaluated for each of these examinations. This study is designed to explore certain tradeoffs between rendering methods designed for the stereo display of CT images. MATERIALS AND METHODS: Stereo CT image compositing methods, including distance-weighted averaging, distance-weighted maximum intensity projection (MIP), and conventional MIP, were applied to lung CT images and compared for lung nodule detection and characterization. RESULTS: Using the Jonckheere test indicated a statistically significant (P < .01) increase in contrast among the three compositing methods. Wilcoxon-Mann-Whitney test showed significant differences in contrast between distance-weighted averaging and conventional MIP (P < .01) and between averaging and distance-weighted MIP (P < .05), but not between distance-weighted MIP and conventional MIP (P > .05). Conventional MIP compositing provided the highest image contrast, but produced ambiguities in local geometric detail and texture, whereas averaging resulted in the lowest contrast, but preserved geometric detail. Distance-weighted MIP partially recovered geometric information, which was lost in images composited by means of conventional MIP. CONCLUSION: Our results indicate that distance-weighted MIP may be a better choice for nodule detection in stereo lung CT images for its high local contrast and partial preservation of geometric information, whereas compositing by means of distance-weighted averaging is preferable for nodule characterization. The relative clinical value of these compositing methods needs to be evaluated further.

Algorithms↗

Is maximum positive predictive value a good indicator of an optimal screening mammography practice?

OBJECTIVE: Positive predictive value (PPV1) has been used as one important indicator of the quality of screening mammography programs. We show how the relationship between sensitivity and recall rate may affect the operating point at which optimal (maximum) PPV1 occurs. CONCLUSION: Optimal (maximum) PPV1 can occur at any sensitivity level and should not be used as the sole indicator for practice optimization because it does not take into account the number of cancers that would be missed at that sensitivity.

Breast Neoplasms↗

Computer-aided detection performance in mammographic examination of masses: assessment.

PURPOSE: To compare performance of two computer-aided detection (CAD) systems and an in-house scheme applied to five groups of sequentially acquired screening mammograms. MATERIALS AND METHODS: Two hundred nineteen film-based mammographic examinations, classified into five groups, were included in this study. Group 1 included 58 examinations in which verified malignant masses were detected during screening; group 2, 39 in which all available latest examinations were performed prior to diagnosis of these malignant masses (subset of 39 women from group 1); group 3, 22 in which findings were interpreted as negative but were verified as cancer within 1 year from the negative interpretation (missed cancers); group 4, 50 in which findings were negative and patients were not recalled for additional procedures; and group 5, 50 in which patients were recalled for additional procedures and findings were negative for cancer. In all examinations, images were processed with two Food and Drug Administration-approved commercially available CAD systems and an in-house scheme. Performance levels in terms of true-positive detection rates and number of false-positive identifications per image and per examination were compared. RESULTS: Mass detection rates in positive examinations (group 1) were 67%-72%. Detection rates among three systems were not significantly different (P > .05). In 50 negative screening examinations (group 4), false-positive rates ranged from 1.08 to 1.68 per four-view examination. Performance level differences among systems were significant for false-positive rates (P = .008). Performance of all systems was at levels lower than publicly suggested in some retrospective studies. False-positive CAD cueing rates were significantly higher for negative examinations in which patients were recalled (group 5) than they were for those in which patients were not recalled (group 4) (P < or = .002). CONCLUSION: Performance of CAD systems for mass detection at mammography varies significantly, depending on examination and system used. Actual performance of all systems in clinical environment can be improved.

Adult↗

Recall and detection rates in screening mammography.

BACKGROUND: The authors investigated the correlation between recall and detection rates in a group of 10 radiologists who had read a high volume of screening mammograms in an academic institution. METHODS: Practice-related and outcome-related databases of verified cases were used to compute recall rates and tumor detection rates for a group of 10 Mammography Quality Standard Act (MQSA)-certified radiologists who interpreted a total of 98,668 screening mammograms during the years 2000, 2001, and 2002. The relation between recall and detection rates for these individuals was investigated using parametric Pearson (r) and nonparametric Spearman (rho) correlation coefficients. The effect of the volume of mammograms interpreted by individual radiologists was assessed using partial correlations controlling for total reading volumes. RESULTS: A wide variability of recall rates (range, 7.7-17.2%) and detection rates (range, 2.6-5.4 per 1000 mammograms) was observed in the current study. A statistically significant correlation (P < 0.05) between recall and detection rates was observed in this group of 10 experienced radiologists. The results remained significant (P < 0.05) after accounting for the volume of mammograms interpreted by each radiologist. CONCLUSIONS: Optimal performance in screening mammography should be evaluated quantitatively. The general pressure to reduce recall rates through "practice guidelines" to below a fixed level for all radiologists should be assessed carefully.

Breast Neoplasms↗

Changes in breast cancer detection and mammography recall rates after the introduction of a computer-aided detection system.

BACKGROUND: Computer-aided mammography is rapidly gaining clinical acceptance, but few data demonstrate its actual benefit in the clinical environment. We assessed changes in mammography recall and cancer detection rates after the introduction of a computer-aided detection system into a clinical radiology practice in an academic setting. METHODS: We used verified practice- and outcome-related databases to compute recall rates and cancer detection rates for 24 Mammography Quality Standards Act-certified academic radiologists in our practice who interpreted 115,571 screening mammograms with (n = 59,139) or without (n = 56,432) the use of a computer-aided detection system. All statistical tests were two-sided. RESULTS: For the entire group of 24 radiologists, recall rates were similar for mammograms interpreted without and with computer-aided detection (11.39% versus 11.40%; percent difference = 0.09, 95% confidence interval [CI] = -11 to 11; P =.96) as were the breast cancer detection rates for mammograms interpreted without and with computer-aided detection (3.49% versus 3.55% per 1000 screening examinations; percent difference = 1.7, 95% CI = -11 to 19; P =.68). For the seven high-volume radiologists (i.e., those who interpreted more than 8000 screening mammograms each over a 3-year period), the recall rates were similar for mammograms interpreted without and with computer-aided detection (11.62% versus 11.05%; percent difference = -4.9, 95% CI = -21 to 4; P =.16), as were the breast cancer detection rates for mammograms interpreted without and with computer-aided detection (3.61% versus 3.49% per 1000 screening examinations; percent difference = -3.2, 95% CI = -15 to 9; P =.54). CONCLUSION: The introduction of computer-aided detection into this practice was not associated with statistically significant changes in recall and breast cancer detection rates, both for the entire group of radiologists and for the subset of radiologists who interpreted high volumes of mammograms.

Breast Neoplasms↗

Mammography with computer-aided detection: reproducibility assessment initial experience.

PURPOSE: To examine the performance and reproducibility of a commercially available computer-aided detection (CAD) system with a set of mammograms obtained in 100 patients who had undergone biopsy after positive findings at mammography. MATERIALS AND METHODS: One hundred positive mammographic examinations (four views each), depicting 96 masses and 50 microcalcification clusters, were scanned and analyzed three times by the CAD system. Reproducibility of detection sensitivity and the individual CAD-generated cues in the three images were examined. Both abnormality- and region-based detection sensitivities were compared. RESULTS: Forty-eight (96.0%) of 50 microcalcification clusters were marked on all three images in the abnormality-based analysis. Of the remaining two clusters, one was marked in two images and one was marked in only one. The abnormality-based sensitivity for mass detection ranged from 66.7% (64 of 96) to 70.8% (68 of 96). The system generated identical patterns (including images with and those without cues) for all three images in 53.3% (213 of 400) of images. For true-positive cluster regions, 88.9% (80 of 90) were marked at the same location in all images. For true-positive mass regions, 69.5% (82 of 118) were marked at the same locations in all images. In false-positive detections, only 44.0% (81 of 184) of false-positive mass regions and 31.9% (38 of 119) of false-positive cluster regions were marked at the same locations on all three images. CONCLUSION: Reproducibility of marked regions generated by the CAD system is improved from that reported previously, largely as a result of the substantial reduction in the false-positive detection rates. Reproducibility of true-positive identification of masses remains an important issue that may have methodologic and clinical practice implications.

Biopsy↗

Performance change of mammographic CAD schemes optimized with most-recent and prior image databases.

RATIONALE AND OBJECTIVES: The authors evaluated performance changes in the detection of masses on "current" (latest) and "prior" images by computer-aided diagnosis (CAD) schemes that had been optimized with databases of current and prior mammograms. MATERIALS AND METHODS: The authors selected 260 pairs of matched consecutive mammograms. Each current image depicted one or two verified masses. All prior images had been interpreted originally as negative or probably benign. A CAD scheme initially detected 261 mass regions and 465 false-positive regions on the current images, and 252 corresponding mass regions (early signs) and 471 false-positive regions on prior images. These regions were divided into two training and two testing databases. The current and prior training databases were used to optimize two CAD schemes with a genetic algorithm. These schemes were evaluated with two independent testing databases. RESULTS: The scheme optimized with current images produced areas under the receiver operating characteristic curve of (0.89 +/- 0.01 and 0.65 +/- 0.02 when tested with current images and prior images, respectively. The scheme optimized with prior images produced areas under the receiver operating characteristic curve of 0.81 +/- 0.02 and 0.71 +/- 0.02 when tested with current images and prior images, respectively. Performance changes for both current and prior testing databases were significant (P < .01) for the two schemes. CONCLUSION: CAD schemes trained with current images do not perform optimally in detecting masses depicted on prior images. To optimize CAD schemes for early detection, it may be important to include in the training database a large fraction of prior images originally reported as negative and later proven to be positive.

Algorithms↗

Epidural labor analgesia for a patient with disseminated lymphangiomatosis.

IMPLICATIONS: We describe a case of a parturient with disseminated lymphangiomatosis involving the thorax, retroperitoneum, and lumbar vertebrae who received epidural labor analgesia. Clinical presentations vary depending on the organ systems involved, the extent of the disease, and the stage of pregnancy. Anesthetic implications are discussed.

Adult↗

Prescreening mammography by technologists: a preliminary assessment.

OBJECTIVE: We assessed the ability of technologists to accurately classify screening mammograms as either showing negative findings or requiring follow-up. SUBJECTS AND METHODS: In a prospective study, 33 technologists at a central facility and five satellite breast imaging facilities recorded whether mammograms obtained during 3019 examinations showed negative findings or findings that indicated that additional procedures were required. The technologists were not specifically trained for the experiment. The technologists' interpretations were compared with radiologists' interpretations. RESULTS: Technologists and radiologists agreed in 82% of the cases (77% negative findings and 5% requiring follow-up). Of the 175 cases recommended for follow-up by only the radiologists, 17 were ultimately biopsied and two were found to be malignant. CONCLUSION: Even without undergoing additional training, technologists can perform at reasonable levels of accuracy in classifying screening mammograms. The possibility of using technologists to group cases after the technologists have undergone training is an interesting concept that should be explored further.

Allied Health Personnel↗

Optimal reference mammography: a comparison of mammograms obtained 1 and 2 years before the present examination.

OBJECTIVE: We assessed and compared the benefit of using images acquired 1 year or 2 years previously during mammography interpretations. MATERIALS AND METHODS: Eleven radiologists and one resident reviewed 128 cases three times: once without prior mammograms for comparison, once with mammograms from the most recent (1 year) examination, and once with mammograms acquired 2 years previously. They were asked to determine whether the patient should be recalled for additional procedures. Performances under the three conditions were compared. RESULTS: Radiologists were significantly more accurate (p < 0.001) when comparison mammograms (obtained 1 or 2 years previously) were available. Although sensitivity was not significantly affected between the availability of mammograms from 1 or 2 years earlier (p > 0.10), the specificity was. Specificity using mammograms from the latest examination (obtained 1 year previously) as a reference was significantly better (p = 0.03) than specificity using mammograms obtained 2 years previously. CONCLUSION: Comparison mammograms are important for accurate diagnosis-in particular, for increasing specificity. The latest prior examination seems to be the optimal one for this purpose.

Breast Neoplasms↗