Mammography with computer-aided detection: reproducibility assessment initial experience.

Abstract

PURPOSE: To examine the performance and reproducibility of a commercially available computer-aided detection (CAD) system with a set of mammograms obtained in 100 patients who had undergone biopsy after positive findings at mammography. MATERIALS AND METHODS: One hundred positive mammographic examinations (four views each), depicting 96 masses and 50 microcalcification clusters, were scanned and analyzed three times by the CAD system. Reproducibility of detection sensitivity and the individual CAD-generated cues in the three images were examined. Both abnormality- and region-based detection sensitivities were compared. RESULTS: Forty-eight (96.0%) of 50 microcalcification clusters were marked on all three images in the abnormality-based analysis. Of the remaining two clusters, one was marked in two images and one was marked in only one. The abnormality-based sensitivity for mass detection ranged from 66.7% (64 of 96) to 70.8% (68 of 96). The system generated identical patterns (including images with and those without cues) for all three images in 53.3% (213 of 400) of images. For true-positive cluster regions, 88.9% (80 of 90) were marked at the same location in all images. For true-positive mass regions, 69.5% (82 of 118) were marked at the same locations in all images. In false-positive detections, only 44.0% (81 of 184) of false-positive mass regions and 31.9% (38 of 119) of false-positive cluster regions were marked at the same locations on all three images. CONCLUSION: Reproducibility of marked regions generated by the CAD system is improved from that reported previously, largely as a result of the substantial reduction in the false-positive detection rates. Reproducibility of true-positive identification of masses remains an important issue that may have methodologic and clinical practice implications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bin Zheng, Lara A Hardesty, William R Poller, Jules H Sumkin, Sara Golla. 2003-05-20. Mammography with computer-aided detection: reproducibility assessment initial experience.. https://doi.org/10.1148/radiol.2281020489

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Non-radical diagnostic biopsies do not negatively influence melanoma patient survival.

BACKGROUND: In fair-skinned Caucasian populations both the incidence and mortality rates of cutaneous melanoma have been increasing over the past decades. With adjuvant therapies still being under investigation, early detection is the only way to improve melanoma patient survival. The influence of incisional biopsies on melanoma patient survival has been discussed for many years. This study investigates both the influence of diagnostic biopsy type and the presence of residual tumor cells in the re-excision specimen on disease free and overall survival. METHODS: After (partial) removal of a pigmented skin lesion 471 patients were diagnosed with stage I/II melanoma and underwent re-excision and a sentinel node biopsy. All patients were followed prospectively, mean follow up >5 years. Patients were divided according to their diagnostic biopsy type (wide excision biopsy, narrow excision biopsy, excision biopsy with positive margins and incisional biopsy) and the presence of residual tumor cells in their re-excision specimen. Survival analysis was done using Cox's proportional hazard model adjusted for eight important confounders of melanoma patient survival. RESULTS: The diagnostic biopsy was wide in 279 patients, narrow in 109 patients, 52 patients underwent an excision biopsy with positive margins and 31 patients an incisional biopsy. In 41 patients residual tumor cells were present in the re-excision specimen. Both the diagnostic biopsy type and the presence of tumor cells in the re-excision specimen did not influence disease free and overall survival of melanoma patients. CONCLUSIONS: Non-radical diagnostic biopsies do not negatively influence melanoma patient survival.

Biopsy↗