Comparison of implantation of nonthoracotomy defibrillators in the operating room versus the electrophysiology laboratory.

Implantable cardioverter-defibrillators (ICDs) with nonthoracotomy lead systems are widely available, and are implanted either in the electrophysiology laboratory or the operating room. The purpose of this study was to prospectively evaluate the safety and efficacy of nonthoracotomy ICD implantation in an electrophysiology laboratory versus an operating room. During a 7-month period, 62 consecutive ICDs with nonthoracotomy lead systems were implanted in patients in an electrophysiology laboratory. During the next 10 months, 110 consecutive ICDs were implanted in patients in a surgical operating room. All ICD implantations were performed under general anesthesia by electrophysiologists. There were no differences in age (58 +/- 14 vs 62 +/- 12 years, p = 0.06), gender distribution (p = 0.3), frequency of structural heart disease (97% vs 97%, p = 0.9), ejection fraction (0.31 +/- 0.15 vs 0.29 +/- 0.13, p = 0.3), or presentation with cardiac arrest (65% vs 53%, p = 0.2) between patients undergoing ICD implantation in the electrophysiology laboratory and operating room, respectively. The rate of successful implantation and of complications for systems implanted in the electrophysiology laboratory (95% and 13%, respectively) and in the operating room (98% and 14%, respectively) were similar (p = 0.4 and p = 0.8, respectively). Specifically, the rate of infection (0% vs 4%, p = 0.3) and hematoma formation (2% vs 4%, p = 0.8) were not statistically significantly different. Three patients who had undergone ICD implantation in an operating room died within 30 days. ICDs with nonthoracotomy lead systems can be implanted with a similarly high rate of success and acceptable complication rate in the electrophysiology laboratory and in the operating room.

Adult↗

Effect of accessory pathway location on the efficiency of heating during radiofrequency catheter ablation.

During radiofrequency catheter ablation of accessory pathways there is a poor correlation between applied power and temperature at target sites for catheter ablation. This study was designed to examine the relation between power and temperature during radiofrequency catheter ablation in patients with accessory pathways and to identify the factors that affect the efficiency of heating, defined as the ratio of applied power and temperature. Twenty-nine patients underwent radiofrequency catheter ablation of an accessory pathway. Among 257 energy applications, 108 were applied for ablation of a right-sided accessory pathway, 105 for a left-sided accessory pathway, and 44 for a posteroseptal accessory pathway. During each application of radiofrequency energy, temperature was continually monitored by use of an ablation catheter with a thermistor embedded in the tip of the distal electrode. During some applications of energy, fluctuations in temperature were observed. The average power, impedance, temperature, and efficiency of heating for all applications of radiofrequency energy was 37 +/- 11 W, 100 +/- 9 ohms, 53 +/- 9 degrees C, and 1.7 +/- 0.8 degrees C/W (range 0.9 degrees to 6.6 degrees C/W), respectively. The efficiency of heating varied by location (p < 0.0001), with the greatest efficiency of heating for posteroseptal energy applications (2.3 +/- 1.2 degrees C/W, which were significantly greater than for left-sided (1.8 +/- 0.8 degrees C/W; p < 0.01) or right-sided (1.2 +/- 0.4 degrees C/W; p < 0.0001) applications. Phasic fluctuation in temperature was observed during 127 (49%) energy applications, and the efficiency of heating was 1.5 +/- 0.7 degrees C/W.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Comparison of early and late complications in patients undergoing coronary artery bypass graft surgery with and without concomitant placement of an implantable cardioverter defibrillator.

Previous studies have reported a significant morbidity and mortality associated with coronary artery bypass graft (CABG) surgery in conjunction with the placement of an implantable cardioverter defibrillator (ICD) with an epicardial lead system. In the absence of a control group, how significantly the component of concomitant placement of the ICD system contributes to these untoward outcomes remains unknown. The purpose of this study was to assess the short- and long-term complications in patients undergoing CABG surgery in conjunction with the placement of an ICD with epicardial leads and to compare these complications with those of patients who had only CABG surgery (control group). The study group (group A) consisted of 56 patients who underwent CABG surgery and placement of an ICD pulse generator with epicardial leads. A control group (group B) consisted of 56 patients who underwent CABG surgery only during the same time period. The two groups were matched for age, sex distribution, left ventricular function, surgical approach, number of bypass grafts per patient, bypass pump time, and length of follow-up period. The early mortality for group A was 7.1% versus 1.8% for group B (p > 0.05). The incidence of early morbidity (congestive heart failure, infection, supraventricular and ventricular arrhythmias) for groups A and B was similar (26.8% vs 25.0%, p > 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Relation between impedance and temperature during radiofrequency ablation of accessory pathways.

Temperature monitoring is a useful tool for radiofrequency ablation of accessory pathways. Impedance monitoring is also helpful, and an impedance fall of 20 ohm may predict coagulum formation. Therefore the purpose of this study was to prospectively quantitate the correlation between impedance and temperature during radiofrequency ablation. Thirty-three consecutive patients underwent radiofrequency ablation with a thermistor ablation catheter with continuous temperature and impedance monitoring during each energy application. The initial and final impedance and temperature measurements for 319 applications of radiofrequency energy were 109 +/- 17 ohm and 102 +/- 17 ohm (p < 0.0001), respectively, and 37 +/- 1 degree C and 57 degrees +/- 11 degrees C (p < 0.0001), respectively. Among the 319 applications of radiofrequency energy, 158 were associated with > or = 20 degrees C increase in tissue temperature, and 10 were associated with coagulum formation. A > or = 20 degrees C increase in tissue temperature was observed in 84 of 104 applications associated with a 5 to 10 ohm decrease in impedance (81% positive predictive value and 93% negative predictive value). The mean change in impedance for applications associated with and without coagulum formation was -19 +/- 7 ohm and -6 +/- 6 ohm (p < 0.0001), respectively, and coagulum formation never occurred with less than a 12 ohm decrease. In conclusions successful tissue heating without coagulum formation can be achieved by titrating the power to achieve a 5 to 10 ohm decrement in impedance. Impedance decrements beyond 10 ohm increase the likelihood of coagulum formation.

Adult↗

Incidence of implantable defibrillator discharges after coronary revascularization in survivors of ischemic sudden cardiac death.

Coronary revascularization has been suggested as sole therapy for secondary prevention of sudden cardiac arrest associated with ischemia. The use of implantable defibrillators (ICD) in combination with coronary revascularization for this patient population is unclear. Among 412 consecutive patients receiving an ICD, 23 (6%) were identified as sudden cardiac arrest survivors who were noninducible with programmed stimulation and had unstable angina or ischemia on a functional study; they underwent successful coronary revascularization. During a follow-up of 34 +/- 18 months, 10 (43%) of the 23 patients received ICD shocks (8 +/- 8 per patient, range 1 to 22 shocks), and nine of the 10 patients had syncope/presyncope associated with at least one ICD discharge. Patients with ICD discharges were compared with those without ICD discharges, and no clinical characteristics were statistically different between the two groups. In conclusion, revascularization alone may be inadequate therapy for survivors of sudden cardiac arrest associated with ischemia who are noninducible with programmed stimulation, and clinical variables cannot predict which patients are likely to have recurrent malignant ventricular arrhythmias.

Aged↗

Effect of first-phase polarity of biphasic shocks on defibrillation threshold with a single transvenous lead system.

OBJECTIVES: The purpose of this study was to determine whether the polarity of the first phase of a biphasic shock affects the defibrillation threshold. BACKGROUND: The polarity of a monophasic shock has been shown to affect the defibrillation threshold. METHODS: A transvenous defibrillation lead with distal and proximal shocking electrodes was used in this study. In 15 consecutive patients, the defibrillation threshold was determined twice using a step-down protocol, in random order: with the distal coil as the anode for the initial phase (anodal biphasic shock) and with the polarity reversed (cathodal biphasic shock). The power to detect a 5.0-J difference in this study is 0.96. These patients were 61 +/- 11 years old (mean +/- SD), and the mean left ventricular ejection fraction was 0.32 +/- 0.10. RESULTS: Mean defibrillation threshold using anodal biphasic shocks was 9.9 +/- 4.8 J, compared with 9.5 +/- 4.2 J using cathodal biphasic shocks (p = 0.8). In three patients the defibrillation threshold was lower by a mean of 6.3 +/- 2.9 J with the former configuration; in three patients the defibrillation threshold was lower by a mean of 6.7 +/- 2.5 J with the latter configuration; and in nine patients it was the same. Using the standard cathodal configuration, a defibrillation threshold < or = 10 J was obtained in approximately 70% of patients, and a subcutaneous patch was not required in any patient. CONCLUSIONS: The polarity of the first phase of a biphasic shock used with a single transvenous lead does not affect the defibrillation threshold.

Defibrillators, Implantable↗

Radiofrequency ablation of idiopathic left anterior fascicular tachycardia.

INTRODUCTION: A 45-year-old man with idiopathic ventricular tachycardia (VT) having a right bundle branch block configuration with right-axis deviation underwent an electrophysiologic test. METHODS AND RESULTS: Mapping demonstrated a site on the anterobasal wall of the left ventricle where there was an excellent pace map and an endocardial activation time of -20 msec, but radiofrequency catheter ablation at this site was unsuccessful. At a nearby site, a presumed Purkinje potential preceded the by 30 msec during VT and sinus rhythm, and catheter ablation was effective despite a poor pace map and an endocardial ventricular activation time of zero. CONCLUSION: Idiopathic VT with a right bundle branch configuration and right-axis deviation may originate in the area of the left anterior fascicle. A potential presumed to represent a Purkinje potential may be more helpful than endocardial ventricular activation mapping or pace mapping in guiding ablation of this type of VT.

Catheter Ablation↗

Assessment of pacing maneuvers used to validate anterograde accessory pathway potentials.

Four pacing maneuvers have been proposed to validate an anterograde accessory pathway potential (APP): (1) atrial pacing to induce complete block between the atrial electrogram and the APP; (2) ventricular pacing to advance the APP without altering the timing of the atrial electrogram; (3) atrial pacing to induce complete block between the APP and the ventricular electrogram; and (4) ventricular pacing to advance the ventricular electrogram without altering the timing of the APP. The purpose of this study was to assess these validation techniques by applying them to electrograms that simulated APPs but which were known to be atrial in origin. In 32 patients undergoing an electrophysiology procedure, a split atrial electrogram containing two components separated by at least 30 msec (mean 54 +/- 15 msec) was recorded. Using an atrial extrastimulus technique, complete block between the two components of the atrial electrogram (criterion 1) could never be induced, but complete block between the second component of the atrial electrogram and the ventricular electrogram (criterion 3) consistently was induced. Using a ventricular extrastimulus technique, the second component of the atrial electrogram consistently could be advanced by 10 to 40 msec without altering the timing of the first component (criterion 2). In addition, with ventricular pacing, the ventricular electrogram consistently was advanced without altering the timing of the two components of the atrial electrogram (criterion 4). In conclusion, among the four pacing maneuvers used to validate an anterograde APP, the only one that may be specific for an APP is the ability to induce complete block between the atrial electrogram and the APP.

Adult↗

A quantitative fluoroscopic comparison of the coronary sinus ostium in patients with and without AV nodal reentrant tachycardia.

INTRODUCTION: The purpose of this study was to perform a quantitative fluoroscopic analysis of the coronary sinus ostium and its relationship to the His bundle in patients with and without AV nodal reentrant tachycardia. Sites of slow pathway ablation are often near the coronary sinus ostium, which can be located within a few millimeters of the His bundle. Whether such close proximity of the coronary sinus ostium to the His bundle is unique to patients with AV nodal reentrant tachycardia is unknown. METHODS AND RESULTS: Fifty consecutive patients (mean age 39 +/- 14 years) with no structural heart disease underwent electrophysiologic testing and radiofrequency ablation. The study group consisted of 28 patients with inducible AV nodal reentrant tachycardia or dual AV nodal physiology and 22 patients in the control group. A coronary sinus venogram was performed in each patient. The coronary sinus ostium was similar in size in the study group (11.4 +/- 4.5 mm) and in the control group (10.5 +/- 3.6 mm, P = 0.2). The coronary sinus ostium was funnel shaped in half of the study patients and in half of the control patients (P = 1.0). The mean distance from the upper lip of the coronary sinus ostium to the tip of the His bundle catheter was 9.7 +/- 5.5 mm in the study group and 10.4 +/- 5.1 mm in the control group (P = 0.7). The mean distance from the lower lip of the coronary sinus ostium to the tip of the His-bundle catheter in the study group was 20.1 +/- 6.1 mm and 19.5 +/- 5.6 mm in the control group (P = 0.7). CONCLUSION: This study demonstrates a wide range of normal coronary sinus ostium diameters, morphology, and anatomic relationships with surrounding structures, with no demonstrable correlation to the presence or absence of dual AV node physiology or AV nodal reentrant tachycardia.

Adolescent↗

Comparison of atrial-His intervals during tachycardia and atrial pacing in patients with long RP tachycardia.

INTRODUCTION: The purpose of this study is to describe a simple and reliable diagnostic maneuver that allows for the rapid differentiation of atypical AV nodal reentrant tachycardia (AVNRT) from other causes of long RP tachycardia. Long RP tachycardias may be caused by atypical AVNRT, orthodromic reciprocating tachycardia (ORT) involving a slowly conducting retrograde accessory pathway, or atrial tachycardia. The differentiation of atypical AVNRT from ORT or atrial tachycardia may be difficult, especially when the differential diagnosis includes a posteroseptal accessory pathway or an atrial tachycardia arising in the posteroseptal right atrium. METHODS AND RESULTS: Twelve patients with atypical AVNRT, 21 with ORT, and 12 with an atrial tachycardia diagnosed using conventional criteria were enrolled in this study. The atrial-His (AH) interval was measured at the His-bundle position during the tachycardia and during atrial pacing from the high right atrium at the tachycardia cycle length in the setting of sinus rhythm. In patients with atypical AVNRT, the mean AH interval was 69 69 msec +/- 50 msec (+/- SD) longer during high right atrial pacing than during the tachycardia (P < 0.001). In 10 of 12 patients with atypical AVNRT, the AH interval during atrial pacing was more than 40 msec longer than the AH interval measured during the tachycardia. In contrast, in patients with ORT or atrial tachycardia, the differences in AH interval between atrial pacing and tachycardia were never more than 20 and 10 msec, respectively. CONCLUSION: The difference in the AH interval between atrial pacing and the tachycardia allows a simple and rapid means of differentiating atypical AVNRT from other types of long RP tachycardias.

Adult↗

Electrophysiologic effects of sotalol and amiodarone in patients with sustained monomorphic ventricular tachycardia.

No prospective studies have compared sotalol and amiodarone during electropharmacologic testing. The purpose of this prospective, randomized study was to compare the electrophysiologic effects of sotalol and amiodarone in patients with coronary artery disease and sustained monomorphic ventricular tachycardia (VT). Patients with coronary artery disease and sustained monomorphic VT inducible by programmed stimulation were randomly assigned to receive either sotalol (n = 17) or amiodarone (n = 17). The sotalol dose was titrated to 240 mg twice daily over 7 days. Amiodarone dosing consisted of 600 mg 3 times daily for 10 days. An electrophysiologic test was performed in the baseline state and at the end of the loading regimen. An adequate response was defined as the inability to induce VT or the ability to induce only relatively slow hemodynamically stable VT. During the follow-up electrophysiologic test, 24% of patients taking sotalol and 41% of those taking amiodarone had an adequate response to therapy (p = 0.30). Amiodarone lengthened the mean VT cycle length to a greater degree than sotalol (28% vs 12%, p < 0.01). There were no significant differences in the effects of sotalol and amiodarone on the ventricular effective refractory period. In patients with coronary artery disease, amiodarone and sotalol are similar in efficacy in the treatment of VT as assessed by electropharmacologic testing. The effects of the 2 drugs on ventricular refractoriness are similar, but amiodarone slows VT to a greater extent than sotalol.

Aged↗

Radiofrequency catheter modification of atrioventricular conduction to control the ventricular rate during atrial fibrillation.

BACKGROUND: In some patients with atrial fibrillation, the ventricular rate may be difficult to control with medications. We evaluated a radiofrequency catheter technique to modify atrioventricular conduction in atrial fibrillation in order to control the ventricular rate without creating pathologic atrioventricular block. METHODS: We studied 19 consecutive patients with atrial fibrillation and uncontrolled ventricular rates refractory to drug therapy. They had had atrial fibrillation for a mean (+/- SD) of 5.5 +/- 4.9 years, had had 4.9 +/- 0.9 unsuccessful drug trials, and were 62 +/- 15 years old. Before the procedure, the maximal ventricular rate during exercise was 180 +/- 39 beats per minute. A total of 11 +/- 5 radiofrequency-energy applications were delivered to the posterior septal or midseptal right atrium, near the ostium of the coronary sinus. RESULTS: Successful control of the ventricular rate without pathologic atrioventricular block was achieved in 14 of the 19 patients (74 percent). Persistent third-degree atrioventricular block requiring a permanent pacemaker occurred inadvertently in four patients (21 percent). Atrioventricular conduction was intentionally ablated in one patient. The 14 patients who had successful modification of conduction had persistent reductions in maximal ventricular rate during exercise (rate at three months, 126 +/- 24 beats per minute; P < 0.01). These patients had resolution of symptoms related to rapid rates during 8 +/- 2 months of follow-up. One patient had a recurrence of a rapid ventricular rate but was again asymptomatic after a second modification procedure. One patient with dilated cardiomyopathy died suddenly, five months after a successful procedure. CONCLUSIONS: A catheter technique to modify atrioventricular conduction without creating pathologic atrioventricular block is feasible in the majority of patients with symptomatic atrial fibrillation and a rapid ventricular rate refractory to drug therapy.

Adult↗

Relation between impedance and endocardial contact during radiofrequency catheter ablation.

Lesion size during radiofrequency catheter ablation in patients with paroxysmal supraventricular tachycardia (PSVT) is thought to be related to multiple factors, including contact pressure at the catheter-endocardial interface. Therefore a predictor of contact pressure at a potential target site for ablation might be useful. In this study 25 patients underwent duplicate 2 W applications of radiofrequency energy with the catheter in poor and firm contact with the right ventricular endocardium after successful ablation treatment for PSVT. The mean age of the patients was 44 +/- 15 years. Fifteen patients underwent slow pathway ablation for atrioventricular nodal reentrant tachycardia, and 10 patients underwent ablation for an accessory pathway. The mean impedance for low-energy applications in firm contact (139 +/- 24 ohms) was 22% +/- 13% greater (p 0.0001) than in poor contact with the right ventricle (113 +/- 16 ohms). The maximum impedance was 27% greater when the catheter was in firm (147 +/- 28 ohms) rather than poor contact (116 +/- 16 ohms), with the endocardium (p 0.0001). These results suggest that higher impedance measurements may be obtained with low-energy applications of 2 W when the ablation catheter is in firm contact with the endocardium.

Adult↗

Effect of shock polarity on ventricular defibrillation threshold using a transvenous lead system.

OBJECTIVES: The purpose of this study was to determine whether the polarity of a monophasic shock used with a transvenous lead system affects the defibrillation threshold. BACKGROUND: The ability to implant an automatic defibrillator depends on achieving an adequate defibrillation threshold. METHODS: A transvenous defibrillation lead with distal and proximal shocking electrodes was used in this study. In 29 consecutive patients, the defibrillation threshold, using a stepdown protocol was determined twice in random order: 1) with the distal coil as the anode, and 2) with the polarity reversed. Only the 20 patients in whom an adequate defibrillation threshold could be obtained with the transvenous lead alone were included in this study. These patients were 61 +/- 14 years old (mean +/- SD) and had a mean ejection fraction of 28 +/- 12%. RESULTS: The mean defibrillation threshold was 11.5 +/- 5.0 J with the distal coil as the anode versus 16.9 +/- 7.7 J with the distal coil as the cathode (p = 0.04). The defibrillation threshold was lower by a mean of 9 +/- 7 J with the former configuration in 14 patients and was lower by a mean of 7 +/- 6 J with the latter configuration in 3 patients; in 3 patients it was the same with both configurations. Use of a subcutaneous patch was avoided in five patients by utilizing the distal electrode as the anode. CONCLUSIONS: Defibrillation thresholds with monophasic shocks are approximately 30% lower with the distal electrode as the anode. The use of anodal shocks may obviate the need for a subcutaneous patch and allow more frequent implantation of a transvenous lead system.

Adult↗

The economic impact of transvenous defibrillation lead systems.

The purpose of this study was to compare implant charges and convalescence for transvenous and epicardial defibrillation systems. Hospital stay, intensive care utilization, professional fees, and hospital bills were compared in 44 patients who underwent implantation of a cardiac defibrillator between September 1991 and May 1993. Twenty-five consecutive patients received an epicardial lead system, while 19 consecutive patients underwent implantation of the entire transvenous defibrillation system in the electrophysiology laboratory. There were no significant differences between the two groups in mean age or left ventricular ejection fraction. There was a significant reduction in postoperative hospital convalescence from 7.2 +/- 2.0 days with epicardial systems to 3.1 +/- 1.5 days with transvenous systems (P < 0.001). Postoperative intensive care unit stay was significantly reduced with transvenous systems compared with epicardial systems (0.1 +/- 0.2 vs 1.5 +/- 0.9 days; P < 0.001). Hospital charges were also significantly reduced with the transvenous lead system implants. Mean implant charges were lower with transvenous systems: $32,090 +/- $2,620 vs $38,307 +/- $2,701 (P < 0.001); convalescence charges were lower: $5,861 +/- $5,010 $12,447 +/- $4,969 (P < 0.001); the total hospital bill was also significantly lower with transvenous systems: $53,459 +/- $12,588 vs $71,981 +/- $16,172 (P < 0.001). Professional fees for implantation ($4,131 +/- $1,724 vs $6,100 +/- 0, P < 0.001), convalescence care ($1,258 +/- $960 vs $2,846 +/- $1,770; P < 0.001), and total professional fees ($12,925 +/- $4,772 vs $15,731 +/- $4,055, P < 0.05) were lower in the transvenous defibrillation group.(ABSTRACT TRUNCATED AT 250 WORDS)

Convalescence↗