PubMed Health⌕ Search

Biomedical subjects

K C Man

Publications and source records attributed to K C Man.

88 records · Page 5Linked to original sources

Effect of pacing site on the atrial electrogram at target sites for slow pathway ablation in patients with atrioventricular nodal reentrant tachycardia.

Atrial electrograms recorded from target sites during radiofrequency catheter ablation of the slow atrioventricular (AV) nodal pathway are often fractionated and may be associated with a late, high frequency component (the slow pathway potential). The purpose of the current study was to assess the effects of slow pathway ablation on the morphology of the atrial electrogram and to determine whether target site electrograms display direction dependent changes in morphology during atrial pacing maneuvers. Twenty-six patients with typical AV nodal reentry had electrograms recorded from target sites before and after successful ablation of the slow AV nodal pathway and during pacing from the high right atrium and distal coronary sinus at cycle lengths of 500 and 300 msec. There was no significant change in the duration or degree of fractionation of the atrial electrogram as the result of slow pathway ablation. In contrast, the duration and degree of fractionation were less when pacing from the coronary sinus compared with sinus rhythms or right atrial pacing. Pacing rate did not affect electrogram morphology. These data suggest that the morphology of the slow pathway target site electrogram is dependent on the direction of atrial activation and that the "slow pathway potential" does not represent activation of an anatomically discrete pathway.

Adult↗

Effects of partial and complete ablation of the slow pathway on fast pathway properties in patients with atrioventricular nodal reentrant tachycardia.

INTRODUCTION: The purpose of this study was to prospectively compare the effects of complete and partial ablation of slow pathway function on the fast pathway effective refractory period (ERP). METHODS AND RESULTS: The subjects were 20 patients (mean age 43 +/- 13 years) with atrioventricular nodal reentrant tachycardia (AVNRT), no structural heart disease, and easily inducible AVNRT. Autonomic blockade was achieved with propranolol (0.2 mg/kg) and atropine (0.04 mg/kg). After elimination of AVNRT and during autonomic blockade, the presence of residual slow pathway function was determined by the presence of a single AV nodal echo and/or dual AV nodal physiology. After autonomic blockade and before ablation, the mean fast pathway ERP was 319 +/- 44 msec and the mean slow pathway ERP was 251 +/- 31 msec. After slow pathway ablation and during autonomic blockade, 7 patients had residual slow pathway function and 13 did not. Complete loss of slow pathway function was associated with a shortening of the fast pathway ERP from 334 +/- 35 msec to 300 +/- 62 msec (P < 0.01), while the fast pathway ERP did not change significantly in patients with residual slow pathway function (291 +/- 29 msec vs 303 +/- 38 msec, respectively; P = 0.08). A shortening of 30 msec or more in the fast pathway ERP was observed in 11 of 13 patients who did not have residual slow pathway function, compared to 0 of 7 patients with residual slow pathway function (P < 0.001). CONCLUSION: Shortening of the fast pathway ERP after successful ablation of AVNRT is dependent upon complete loss of slow pathway function. This observation is consistent with electrotonic inhibition of the fast pathway by the slow pathway.

Adult↗

Implantation by electrophysiologists of 100 consecutive cardioverter defibrillators with nonthoracotomy lead systems.

BACKGROUND: Traditional lead systems for implantable cardioverter defibrillators (ICDs) require a thoracotomy for placement. Nonthoracotomy lead systems are available and are usually implanted by an electrophysiologist and a surgeon. The purpose of this study was to prospectively evaluate the safety and efficacy of ICD implantation with a nonthoracotomy lead system by electrophysiologists. METHODS AND RESULTS: A consecutive series of 100 patients (mean age, 61 +/- 13 years, +/- SD) underwent ICD implantation with a nonthoracotomy lead system while intubated and under general anesthesia. Seventy-seven patients had coronary artery disease, 15 had idiopathic cardiomyopathy, 6 had miscellaneous heart disease, and 2 had structurally normal hearts. The mean ejection fraction was 0.29 +/- 0.13. Sixty-eight patients had suffered a cardiac arrest, and 32 had had ventricular tachycardia or syncope. All patients except 9 underwent electrophysiological testing and had failed 1 +/- 1 drug trials before ICD implantation. Three types of nonthoracotomy lead systems were used. The nonthoracotomy lead with an ICD was successfully implanted in 96 patients (96%). Of the unsuccessful implants, 1 patient did not have venous access, the passive fixation lead in 1 would not remain lodged, 1 had elevated defibrillation thresholds, and 1 developed a hemopneumothorax while venous access was being obtained. The mean defibrillation threshold was 17 +/- 6 J. The mean procedure duration was 161 +/- 57 minutes. When a subcutaneous patch was used (n = 58), the procedure duration was 189 +/- 5 minutes, and when a subcutaneous patch was not required (n = 40), the procedure lasted 123 +/- 37 minutes (P < .0001). Patients remained in the hospital 4.5 +/- 4.1 days after implantation, with no procedure-related deaths. Acute complications occurred in 10 patients; 2 had lead dislodgments, 1 with previous abdominal surgery had his abdominal cavity entered (without other complications) while the ICD pocket was being made, 1 had postoperative heart failure, 1 developed a large hematoma when anticoagulation therapy was initiated, 3 required reintubation because of excessive anesthesia, 1 developed superficial cellulitis, and 1 developed a hemopneumothorax secondary to a lacerated subclavian vein. During 6 +/- 3 months of follow-up, 2 patients developed lead fractures. CONCLUSIONS: (1) Electrophysiologists can implant an ICD with a nonthoracotomy lead system safely and with a high success rate; (2) use of a subcutaneous patch correlates with longer procedure durations; and (3) special precautions should be taken in patients with previous abdominal surgery.

Anesthesia, General↗

Analysis of junctional ectopy during radiofrequency ablation of the slow pathway in patients with atrioventricular nodal reentrant tachycardia.

BACKGROUND: Junctional ectopy may occur during radiofrequency (RF) catheter ablation of the slow pathway in patients with atrioventricular nodal reentrant tachycardia (AVNRT). The purpose of the present study was to characterize this junctional ectopy quantitatively. METHODS AND RESULTS: The subjects of this study were 52 consecutive patients with AVNRT who underwent slow pathway ablation and 5 additional patients included retrospectively because they had developed high-degree atrioventricular (AV) block during the procedure. A combined anatomic and electrogram mapping approach was used for slow pathway ablation, and AVNRT was successfully eliminated in all patients. In the group of 52 consecutive patients, the incidence of junctional ectopy was significantly higher during 52 effective applications of RF energy than during 366 ineffective applications (100% versus 65%, P < .001). Compared with ineffective RF energy applications, successful RF energy applications had a significantly longer duration of individual bursts of junctional ectopy (7.1 +/- 7.1 versus 5.0 +/- 7.0 seconds [+/- SD], P < .05), a greater total number of junctional beats during the applications (24 +/- 16 versus 15 +/- 8, P < .01), and a greater total span of time during which junctional ectopy occurred (19 +/- 15 versus 11 +/- 12 seconds, P < .01). Four of the 52 patients plus an additional 5 patients developed transient AV block lasting 34 +/- 37 seconds. In 1 of the 9 patients who had transient AV block, third-degree AV nodal block requiring a permanent pacemaker recurred 2 weeks later. In each of the 9 patients who developed AV block, there was ventriculoatrial (VA) block in association with junctional ectopy during the RF energy application immediately preceding the AV block. Among 48 patients who did not develop AV block, 17 patients had at least one episode of VA block during junctional ectopy. The positive predictive value of VA block during junctional ectopy for the development of AV block was 19% in the consecutive series of 52 patients. Among 31 patients who always had 1:1 VA conduction in association with junctional ectopy, 12 had poor VA conduction in the baseline state, with a VA block cycle length of at least 500 milliseconds during ventricular pacing. CONCLUSIONS: In patients with AVNRT undergoing slow pathway ablation, junctional ectopy during the application of RF energy is a sensitive but nonspecific marker of successful ablation. The bursts of junctional ectopy are significantly longer at effective target sites than at ineffective sites. VA conduction should be expected during the junctional ectopy that accompanies slow pathway ablation, even when there is poor VA conduction during baseline ventricular pacing. VA block during junctional ectopy is a harbinger of AV block in patients undergoing RF ablation of the slow pathway. If energy applications are discontinued as soon as VA block occurs, the risk of AV block may be markedly reduced.

Adolescent↗

Results and efficiency of programmed ventricular stimulation with four extrastimuli compared with one, two, and three extrastimuli.

BACKGROUND: Conventional programmed ventricular stimulation protocols are inefficient compared with more recently proposed protocols. The purpose of the present study was to determine if additional efficiency could be derived from a 6-step programmed ventricular stimulation protocol that exclusively uses four extrastimuli. METHODS AND RESULTS: The subjects were 209 consecutive patients with coronary artery disease and documented sustained monomorphic ventricular tachycardia, nonsustained ventricular tachycardia, aborted sudden death, or syncope. These patients underwent 159 electrophysiological tests in the absence of antiarrhythmic drug therapy and 105 electrophysiological tests in the presence of antiarrhythmic therapy. Programmed stimulation was performed with two protocols in random order in each patient. Both protocols used an eight-beat drive train, 4-s intertrain pause, and basic drive cycle lengths of 350, 400, and 600 ms. The 6-step protocol started with coupling intervals of 290, 280, 270, and 260 ms, which were shortened simultaneously in 10-ms steps until S2 was refractory. The 18-step protocol used one, two and three extrastimuli in conventional sequential fashion. The end points were 30 s of sustained monomorphic ventricular tachycardia, two episodes of polymorphic ventricular tachycardia requiring cardioversion, or completion of the protocol at two right ventricular sites. There was no significant difference in the yield of sustained monomorphic ventricular tachycardia using the two protocols, regardless of the clinical presentation or treatment with antiarrhythmic drugs. Polymorphic ventricular tachycardia occurred with the 18-step protocol twice as frequently as with the 6-step protocol (6% versus 3%, P < .001). The duration of the 18-step protocol was significantly longer than that of the 6-step protocol in patients with inducible ventricular tachycardia (5.5 +/- 7 versus 2.3 +/- 2 minutes, P < .001), as well as in patients without inducible ventricular tachycardia (25.4 +/- 7 versus 6.9 +/- 2 minutes, P < .001). CONCLUSION: A stimulation protocol that exclusively uses four extrastimuli improves the specificity and efficiency of programmed ventricular stimulation without compromising the yield of monomorphic ventricular tachycardia in patients with coronary artery disease.

Aged↗

A randomized comparison of the right- and left-sided approaches to ablation of the atrioventricular junction.

Radiofrequency ablation of the atrioventricular (AV) junction may be performed using either a right- or left-sided approach. This study prospectively compared the left-sided approach with persistent attempts from the right side in patients in whom initial radiofrequency applications on the right side were unsuccessful. Twenty-one of 54 patients did not have complete AV block induced after 3 right-sided radiofrequency applications. These 21 patients were randomly assigned to undergo either the left-sided approach (n = 10) or to undergo additional attempts from the right side (n = 11). The right-sided approach was performed by positioning the ablation catheter to record the largest possible atrial and His bundle electrograms. The left-sided approach was performed by positioning the ablation catheter along the left ventricular septum, where a His bundle potential was recorded. If either approach was not successful after an additional 17 radiofrequency applications, the alternative approach was then used. The AV junction was successfully ablated in all 10 patients randomized to the left-sided approach, but in only 6 of 11 patients randomized to persistent right-sided attempts (p < 0.05). The 5 patients in whom the AV junction was not successfully ablated using the right-sided approach underwent the left-sided approach and had a successful outcome after a mean of 1.2 +/- 0.4 radiofrequency applications. The left-sided approach required significantly fewer radiofrequency applications after randomization than the right-sided approach (3 +/- 3.4 vs 11 +/- 7.6, p < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Prospective, randomized comparison of conventional and high dose loading regimens of amiodarone in the treatment of ventricular tachycardia.

OBJECTIVES: The purpose of this prospective randomized study was to compare the electrophysiologic effects of conventional and high dose loading regimens of amiodarone in patients with sustained ventricular tachycardia. BACKGROUND: Uncontrolled studies in which patients have been treated with an oral loading dose of 2 to 4 g/day of amiodarone have suggested that, compared with a conventional loading dose, this dosing regimen results in more rapid control of spontaneous ventricular tachycardia and ventricular tachycardia induced by programmed stimulation. METHODS: Patients in whom sustained monomorphic ventricular tachycardia was inducible by programmed stimulation and who were refractory to class I antiarrhythmic medications were randomly assigned to receive either a conventional (n = 15) or a high (n = 17) loading dose of amiodarone. The conventional dose consisted of 600 mg twice a day for 10 days. The high dose regimen consisted of 50 mg/kg body weight per day on days 1 to 3, 30 mg/kg per day on days 4 and 5 and 600 mg twice a day on days 6 to 10. An electrophysiologic test was performed in the baseline state and after 3 and 10 days of therapy. An adequate response to amiodarone was defined as the inability to induce ventricular tachycardia or the ability to induce only relatively slow (cycle length > or = 350 ms) hemodynamically stable ventricular tachycardia. RESULTS: After 3 days of therapy, 2 of 14 patients who received the conventional loading dose and 6 of 15 patients who received the high dose loading regimen had an adequate response to amiodarone (p = 0.08). After 10 days of therapy, four patients in each group had an adequate response to amiodarone (p = NS). Three patients who received the high dose and one patient who received the conventional dose of amiodarone had an adequate response after 3 days of therapy but not after 10 days of therapy. There were significant increases in the sinus cycle length, atrioventricular block cycle length, ventricular effective refractory period and ventricular tachycardia cycle length after 3 and 10 days of therapy compared with baseline values regardless of the dosing regimen. The extent of the effects of amiodarone on these variables after 3 and 10 days of therapy was similar with both dosing regimens. CONCLUSIONS: The therapeutic and electrophysiologic effects of conventional and high dose loading regimens of amiodarone do not differ significantly after 3 or 10 days of therapy. High oral loading doses of amiodarone do not offer any significant clinical advantage over a conventional loading dose of amiodarone for controlling ventricular tachycardia induced by programmed stimulation.

Aged↗

Recognition and catheter ablation of subepicardial accessory pathways.

OBJECTIVES: The purpose of this study was to characterize left-sided accessory pathways that traverse the atrioventricular (AV) groove subepicardially and to describe results of radiofrequency catheter ablation within the coronary sinus in the patients studied. BACKGROUND: Radiofrequency catheter ablation has proved to be a safe and effective method for treatment of accessory pathways; however, subepicardial accessory pathways may account for some of the failures encountered during endocardial ablation. METHODS: The study group comprised 51 consecutive patients with a left-sided accessory pathway who were undergoing radio-frequency catheter ablation. Initially, the ablation catheter was introduced into a femoral artery and positioned on the ventricular aspect of the mitral annulus. If this endocardial approach was unsuccessful, the ablation catheter was introduced into the coronary sinus and energy applied at sites with shorter activation times than those recorded from the endocardium. RESULTS: Five (10%) of 51 patients with a left-sided accessory pathway could not have accessory pathway conduction interrupted with a median of 18 endocardial radiofrequency energy applications. Accessory pathway potentials were less frequent during endocardial mapping in these 5 patients than in the 46 patients whose accessory pathway was successfully ablated from the endocardial surface. All five of these patients later had successful ablation using one or two applications of radiofrequency energy from within the coronary sinus. Effective target site electrograms in the coronary sinus were characterized by an accessory pathway potential that was larger than the corresponding atrial or ventricular electrogram. There were no complications or recurrences after ablation within the coronary sinus. CONCLUSIONS: Some left-sided accessory pathways may be difficult to ablate from the endocardial surface because they traverse the AV groove subepicardially. The absence of an accessory pathway potential during endocardial mapping in combination with a relatively large accessory pathway potential within the coronary sinus may be a useful marker of a subepicardial pathway. In this select group of patients, radiofrequency catheter ablation from within the coronary sinus appears to enhance efficacy.

Action Potentials↗

Interference from a hand held radiofrequency remote control causing discharge of an implantable defibrillator.

A 46-year-old man with a history of sustained monomorphic ventricular tachycardia underwent an implantation of a third generation multiprogrammable implantable cardioverter defibrillator. One year post implant, while manipulating a remote control to a radiofrequency modulated toy car, the patient experienced a defibrillator discharge not preceded by an arrhythmia prodrome. Subsequent interrogation of the defibrillator revealed that a 34-joule shock had been delivered and had been preceded by RR intervals ranging from 141-406 msec, consistent with sensing lead noise. The remote control utilizes a 12-volt battery and has a carrier frequency of 75.95 MHz and a modulating frequency of 50 Hz. Evaluation of the remote control and defibrillator interaction revealed that the remote control was able to trigger tachyarrhythmia sensing and reproduce the clinical episode. Interference was present only when the remote control was within 8 cm of the pulse generator and at specific angles relative to the device and only when the antenna length was > 45 cm. Interference was eliminated when a ground wire was attached to the antenna and when an aluminium shield was placed between the pulse generator and the remote control. This case report suggests that patients with third generation multiprogrammable defibrillators should be cautioned against close contact with potential sources of electromagnetic interference, such as remote control units.

Artifacts↗

Radiofrequency catheter ablation of atypical atrioventricular nodal reentrant tachycardia.

INTRODUCTION: Published reports of radiofrequency ablation of atypical atrioventricular nodal reentrant tachycardia (AVNRT) have been limited. We present our experience in 10 consecutive patients with atypical AVNRT who underwent radiofrequency ablation of the "slow" AV nodal pathway. METHODS AND RESULTS: There were 9 females and 1 male; their mean age was 44 +/- 19 years (+/- SD). The mean AVNRT cycle length and ventriculoatrial (VA) interval at the His position during AVNRT were 340 +/- 50 msec and 200 +/- 70 msec, respectively. The slow pathway was successfully ablated in all patients with a mean of 10 +/- 7 radiofrequency energy applications in the posteroseptal right atrium near the coronary sinus os. The mean procedure duration was 100 +/- 35 minutes. There were no complications. In 4 patients, target sites were identified during sinus rhythm by mapping for possible slow pathway potentials. In the other 6 patients, target sites were identified by mapping retrograde atrial activation during AVNRT or ventricular pacing. The VA times at successful target sites were a mean of 45 +/- 30 msec less than the VA time at the His catheter during AVNRT. There were no differences in success rate, number of radiofrequency energy applications, or procedure duration between patients in whom mapping was guided by possible slow pathway potentials or by retrograde atrial activation. During 6 +/- 3 months of follow-up, 1 patient had a recurrence of atypical AVNRT and underwent a second ablation procedure, which was successful. CONCLUSION: Radiofrequency ablation of atypical AVNRT can be safely and effectively accomplished when target sites are identified based either on possible slow pathway potentials during sinus rhythm or retrograde atrial activation times during tachycardia.

Adult↗

A radiochemical assay for mitochondrial acetyl-CoA synthase and octanoyl-CoA synthase from rat heart.

A simple radiochemical assay is described for measuring the activity of rat heart mitochondrial acetyl-CoA synthase (EC 6.2.1.1) and octanoyl-CoA synthase (EC 6.2.1.2) using labelled acetate and octanoate. Separation of 14C-labelled reactant from its reaction products was achieved by lyophilization. Enzyme activity was determined by the measurement of incorporation of 14C-labelled short and medium-chain fatty acid into their CoA-derivatives. The method is applicable to the assay of other enzymes where products and substrate may be separated on the basis of the volatilization of one of them during lyophilization.

Acetate-CoA Ligase↗

Interorgan metabolism of amino acids in streptozotocin-diabetic ketoacidotic rat.

Amino acid concentrations in whole blood, liver, kidney, skeletal muscle, and brain were measured and arteriovenous differences calculated for head, hindlimb, kidney, gut, and liver in control and streptozotocin-diabetic rats. In the control rats, glutamine was released by muscle and utilized by intestine, intestine released citrulline and alanine, liver removed alanine, and the kidneys removed glycine and produced serine. In diabetic rats, the major changes from the pattern of fluxes seen in the normal rat were the release of many amino acids from muscle, with glutamine and alanine predominating, and the uptake of these amino acids by the liver. Glutamine removal by the intestine was suppressed in diabetes, but a large renal uptake of glutamine was evident. Branched-chain amino acids were removed by the diabetic brain, and consequently, brain levels of a number of large neutral amino acids were decreased in diabetes.

Amino Acids↗

Inhibition of medium and short-chain fatty acid oxidation in rat heart mitochondria by dichloroacetate.

The effect of dichloroacetate (DCA) on the oxidation of medium-chain and short-chain fatty acids was studied in rat heart mitochondria. Dichloroacetate (1-10 mM) markedly decreased medium-chain and the short-chain fatty acid oxidation (oxygen uptake and release of 14CO2 from labelled fatty acids) by heart mitochondria; the oxidation of long-chain fatty acid, however, was unaffected by the compound. THe oxidation of acylcarnitines was not influenced by DCA. Dichloroacetate inhibited medium-chain and short-chain fatty acid oxidation by inhibiting the activity of mitochondrial acyl-CoA synthases. Inhibition of the enzyme activity by DCA was rapid and not due to its effect on pyruvate dehydrogenase.

Acetates↗