PubMed HealthSearch

Biomedical subjects

K D Wise

Publications and source records attributed to K D Wise.

16 recordsLinked to original sources

A multichannel neural probe for selective chemical delivery at the cellular level.

A bulk-micromachined multichannel silicon probe capable of selectively delivering chemicals at the cellular level as well as electrically recording from and stimulating neurons in vivo has been developed. The process buries multiple flow channels in the probe substrate, resulting in a hollow-core device. Microchannel formation requires only one mask in addition to those normally used for probe fabrication and is compatible with on-chip signal-processing circuitry. Flow in these microchannels has been studied theoretically and experimentally. For an effective channel diameter of 10 microns, a channel length of 4 mm, and water as the injected fluid, the flow velocity at 11 torr is about 1.3 mm/s, delivering 100 pl in 1 s. Intermixing of chemicals with the tissue fluid due to natural diffusion through the outlet orifice becomes significant for dwell times in excess of about 30 min, and a shutter is proposed for chronic use. The probe has been used for acute monitoring of the neural responses to various chemical stimuli in guinea pig superior and inferior colliculus.

Action Potentials

A silicon probe with integrated microheaters for thermal marking and monitoring of neural tissue.

This paper describes a microheater structure and its integration on a silicon microprobe. The 30-micron-diameter microstructure can be used to heat local areas of tissue or to measure local tissue temperature with an accuracy of < 0.3 degree C. The polysilicon microheater is suspended on a dielectric membrane to reduce undesired heat conduction to the probe substrate. The heating efficiency is 4.4 degrees C/mW in still water and 2.2 degrees C/mW in guinea pig cortex. Six milliwatts applied for 2 min in cortex produces a temperature of 50 degrees C, creating a well-defined 50-micron-wide lesion for determining probe position histologically. Fabrication of the heaters requires no additional masking or processing steps in addition to those normally used for recording or stimulating probes.

Animals

Silicon ribbon cables for chronically implantable microelectrode arrays.

This paper describes the design, fabrication, and testing of miniature ultraflexible ribbon cables for use with micromachined silicon microprobes capable of chronic recording and/or stimulation in the central nervous system (CNS). These interconnects are of critical importance in reliably linking these microelectrodes to the external world through a percutaneous connector. The silicon cables allow the realization of multilead, multistrand shielded local interconnects that are extremely flexible and yet strong enough to withstand normal handling and surgical manipulation. Cables 5 microns thick, 1-5 cm long, and from 60 to 250 microns wide have been fabricated with up to eight leads. The series lead resistance is typically 4 k omega/cm for polysilicon and 500 omega/cm for tantalum, with shunt capacitance values of 5-10 pF/cm and an interlead capacitance below 10 fF/cm. Soak tests in buffered saline performed under electrical and mechanical stress have been underway for over three years and show subpicoampere leakage levels. Silicon microprobes with built-in ribbon cables have remained functional for up to one year in the guinea pig CNS, recording driven single-unit activity and maintaining impedance levels in the 1-7 M omega range.

Animals

A three-dimensional microelectrode array for chronic neural recording.

This paper describes a 3-D microelectrode array for the chronic recording of single-unit activity in the central nervous system. The array is formed by a microassembly of planar silicon multishank microprobes, which are precisely positioned in a micromachined platform that resides on the surface of the cortex. Interconnects between the probes and the platform are formed using electroplated nickel lead transfers, implemented using automated computer control. All dimensions are controlled to +/- 1 micron and sank/probe separations as small as 100 microns are possible. Four-probe 16-shank prototype arrays have been tested chronically in guinea pig cortex. After three months in vivo, no significant tissue reaction has been observed surrounding these structures when they remain free to move with the brain, with normal appearing tissue between shanks spaced at 150 microns to 200 microns intervals. The array structure is compatible with the use of signal processing circuitry both on the probes and on the platform. A platform-based signal processing system has been designed to interface with several active probes, providing direct analog access to the recording sites, performing on-chip analog-to-digital conversion of neural activity, and providing simple binary-output recognition of single-unit spike events using a user-input threshold voltage.

Animals

Microfabrication techniques for integrated sensors and microsystems.

Integrated sensors and actuators are rapidly evolving to provide an important link between very large scale integrated circuits and nonelectronic monitoring and control applications ranging from biomedicine to automated manufacturing. As they continue to expand, entire microsystems merging electrical, mechanical, thermal, optical, magnetic, and perhaps chemical components should be possible on a common substrate.

Biosensing Techniques

A low-noise demultiplexing system for active multichannel microelectrode arrays.

This paper reports a low-noise demultiplexing system capable of reconstructing multichannel single-unit neural signals derived from multiplexed microelectrode arrays. The overall multiplexing-demultiplexing system realizes ten channels, a per-channel gain of 68 dB, a bandwidth from 100 Hz to 6 kHz, and an equivalent noise level (referred to the probe input) of 13 microV rms. It provides for signaling over the power supply to allow control of on-chip probe functions such as self-testing. The interchannel crosstalk is less than 3%, and switching noise is suppressed by blanking the transition intervals. The 200 kHz probe sample clock is tracked automatically over a range from 150 to 250 kHz. Neural signals as low as 20 microV (typically 640 microV at the demultiplexing system input) can be reconstructed. The overall system organization is compatible with the demultiplexing of as many as 40 time-multiplexed electrode channels from a single probe data line.

Electric Conductivity

Scaling limitations of silicon multichannel recording probes.

This paper describes the scaling limitations of multichannel recording probes fabricated for use in neurophysiology using silicon integrated circuit technologies. Scaled silicon probe substrates 8 microns thick and 16 microns wide can be fabricated using boron etch-stop techniques. Theoretical expressions for calculating the thickness and width of silicon substrates have been derived and agree closely with experimental results. The effects of scaling probe dimensions on its strength and stiffness are described. The probe shank dimensions can be designed to vary the strength and stiffness for different applications. The scaled silicon substrates have a fracture stress of about 2 x 10(10) dyn/cm2, which is about six times that of bulk silicon, and are strong and very flexible. Scaling the feature sizes of recording electrode arrays down to 1 micron is possible with less than 1 percent electrical crosstalk between channels.

Electronics, Medical

Batch-fabricated thin-film electrodes for stimulation of the central auditory system.

Silicon micromachining and thin-film technology have been employed to fabricate iridium stimulating arrays which can be used to excite discrete volumes of the central nervous system. Silicon multichannel probes with thicknesses ranging from 1 to 40 microns and arbitrary two-dimensional shapes can be fabricated using a high-yield, circuit-compatible process. Iridium stimulating sites are shown to have similar characteristics to iridium wire electrodes. Accelerated pulse testing with over 8 million 100 microA biphasic current pulses on 8000 microns 2 sites has demonstrated the long-term stability of iridium and activated iridium sites. In vivo tests have been performed in the central auditory pathways to demonstrate neural activation using the devices. These tests show a selective activation both as a function of site separation and site size.

Animals