PubMed Health⌕ Search

Biomedical subjects

K Gutensohn

Publications and source records attributed to K Gutensohn.

At least 19 recordsLinked to original sources

Detection of disseminated epithelial cancer cells by liquid culture--factors interfering with the standardization of assays.

BACKGROUND: Immunocytochemistry is the standard method for detection of disseminated breast-cancer cells. Tumor-cell enrichment by cell culture has been used by several investigators, however assays published have not been well-standardized. METHODS: Breast-cancer cells from two lines were diluted in hemopoietic cells of varying origins and cultured in different media and different flasks. Factors influencing successful tumor-cell amplification by liquid culture were identified by investigation of 277 cultures. Parallel clinical samples, consisting of BM aspirations, leukapheresis samples and peripheral blood samples obtained from women with breast cancer, were investigated in 113 cultures. Cancer-cell detection by cell culture could be compared to immunocytochemistry in 101 cases. RESULTS: The frequency of tumor-cell detection was not improved by liquid culture, but a significant correlation between conventional tumor-cell detection and detection after liquid culture was found. Factors influencing tumor-cell amplification in the dilution assay could not be transferred to the investigation of clinical samples. It was concluded that culture-enrichment of disseminated cancer cells was very complex, and could be influenced by a variety of factors-even when a model system was used. DISCUSSION: It should be recognized that culture-enriched cancer cells probably represent a highly selected population of disseminated cancer cells, despite the significant correlation between tumor cells detected by conventional methods and following conventional methods after liquid culture. There is currently no evidence to suggest that cancer-cell amplification by cell culture could become a standardized technique for the detection of disseminated epithelial tumor cells.

Artifacts↗

Enhanced platelet aggregation with TRAP-6 and collagen in platelet aggregometry in patients with venous thromboembolism.

The role of platelet hyperaggregability as a possible risk factor for venous thromboembolism is not well defined. Some authors described enhanced maximal platelet aggregation in platelet aggregometry as a contributing factor for arterial and venous thrombosis. This syndrome has been termed "sticky-platelet syndrome" (SPS). The diagnosis of SPS is based on the demonstration of platelet hyperaggregability in aggregometry after stimulation with epinephrine (EPI) and/or adenosine diphosphate (ADP). We investigated platelet hyperaggregability in platelet-rich plasma (PRP) of patients (n = 34) with unexplained venous thromboembolism in comparison to healthy individuals (n = 53). For analysis, platelet aggregometry was performed and the influence of epinephrine, adenosine diphosphate, collagen (Coll) and thrombin receptor-activated peptide (TRAP-6) as agonist were determined. Compared to the control group, patients with venous thromboembolism showed an enhanced maximal platelet aggregation with low concentrations of TRAP-6 (2 microM) and collagen (0.05 microM). In contrast, we could not detect an increased platelet aggregation with EPI or ADP. Our results indicate that platelet hyperaggregability may represent an independent risk factor in patients with otherwise unexplained venous thromboembolism. In our study, low concentrations of TRAP-6 and collagen are superior to EPI and ADP to define platelet hyperreactivity in platelet aggregometry.

Adult↗

Platelet function testing in apheresis products: flow cytometric, resonance thrombographic (RTG) and rotational thrombelastographic (roTEG) analyses.

During storage of platelet concentrates, quality control of the units is mandatory. This includes the important testing of the hemostatic function of platelets. So far, mostly platelet aggregation analyses have been performed. In this study, new approaches were tested to evaluate the applicability of modern techniques for quality monitoring. Plateletpheresis was performed with two different cell separators (AMICUS cell separator, Fenwal, Baxter Healthcare, Deerfield, USA; COBE Spectra, COBE BCT, Lakewood, USA). In each procedure split products (n = 22) were prepared and stored for 1-2 days (n = 22) or 3 5 days (n = 22). Platelet hemostatic capacity was tested by applying flow cytometry. platelet aggregation (platelet-rich-plasma [PRP]+agonist), resonance thrombography (RTG; PRP, no agonist) and rotational thrombelastography (roTEG; PRP+agonist). Flow cytometric analyses did not reveal significant changes in structural (CD41a. CD42b) or activation-dependent antigens (CD62p, CD63, LIBS, RIBS). Also, differences in the data from the flow cytometric reactivity tests were not significant between the two groups. In platelet aggregation assays, shape change (p = 0.8), maximum aggregation (p = 0.4), and maximum gradient (p = 0.8) did not show significant differences between the two groups. In the RTG test, differences between r-time (reaction time; p = 0.4), and f-time (clot formation time [fibrin influence]; p = 0.3), and in roTEG r-time (coagulation time; p = 0.1) and k-time (clot formation time; p = 1.0) were not significant. P-time (clot formation time [platelet influence]) and M (maximum amplitude) in RTG, and k-time and MA (maximum amplitude) in roTEG showed a slight decrease in platelet function (p < or = 0.05). We conclude that platelet function is well maintained during storage. This is reflected by the results of immunological and platelet function assays. Rotational thrombelastography (in the case of PRP) and especially resonance thrombography represent promising methods for quality control of platelet concentrates and rapidly provide information about the status of platelet function and the whole clotting process.

Blood Coagulation Tests↗

Stem cell mobilisation with 16 microg/kg vs 10 microg/kg of G-CSF for allogeneic transplantation in healthy donors.

We compared two doses of recombinant human granulocyte-stimulating factor (G-CSF) for stem cell mobilisation in 90 healthy donors for allogeneic stem cell transplantation in a retrospective analysis. Group I (n = 46) received 10 microg/kg G-CSF (filgrastim) given as 5 microg/kg twice daily, and group II (n = 44) received 16 microg/kg, given as 8 microg/kg twice daily with a 12-h interval. The groups were well-balanced for age and body-weight. G-CSF application was performed on an out-patient basis, and leukapheresis was started in all donors on day 5. The most frequent side-effects of G-CSF were grade I/II, bone pain, headache and fatigue in both groups, whereas grade III of bone pain, headache and fatigue occurred in the 2 x 8 microg/kg group only. One serious non-fatal event with non-traumatic spleen rupture occurred in the 2 x 5 microg/kg group. The CD34(+)cell count in the first apheresis of all donors was 5.1 x 10(6)/kg donor weight (range, 1.5-19.3). The CD34(+) cell harvest was higher in the 2 x 8 microg/kg group than in the 2 x 5 microg/kg group (7.1 x 10(6)/kg vs 4.9 x 10(6)/kg; P = 0.09). The target of collecting >5.0 x 10(6) CD34(+) cells/kg donor weight with one apheresis procedure was achieved in 45% of group I and in 61% of group II, respectively. Administering G-CSF at a dosage of 8 microg/kg twice daily leads to a higher CD34(+) cell yield than a dosage of 2 x 5 microg/kg, but is associated with increased toxicity and higher cost.

Adult↗

Platelet hemostasis capacity in smokers. In vitro function analyses with 3.2% citrated whole blood.

INTRODUCTION: Platelet function may be influenced by cigarette smoking. We therefore examined the effect of smoking on platelet hemostasis capacity (PHC) with an in vitro analyzer (PFA-100). METHODS AND RESULTS: Healthy blood donors (n=54) were included in the study and divided into four groups: nonsmoking males (n=14), nonsmoking females (n=14), smoking males (n=12) and smoking females (n=14). For in vitro analyses, in each participant citrated blood (3.2% buffered) was tested for PHC by two cartridges coated with collagen, and additionally with epinephrine (Col/Epi) or ADP (Col/ADP). Analyses were performed within 4 h after sample taking. PHC was expressed as the time in seconds to occlude the cartridge (closure time, CT). The average CT was significantly prolonged in female smokers compared to the female nonsmoking group for both types of cartridges (Col/Epi: P=.02; Col/ADP: P=.03). No significant differences were detected comparing the CT of smoking and nonsmoking males. After pooling male and female smokers and nonsmokers, no significant differences could be found, neither for the Col/Epi cartridges nor the Col/ADP cartridges. Plaletet aggregation assays performed in parallel showed no significant differences, except a reduced aggregability in male smokers compared to male nonsmokers using epinephrine 8.0 microM/ml as activating agent (P=.01). Furthermore, smoking volunteers presented with a significantly increased fibrinogen level compared to nonsmoking volunteers (P<.01). CONCLUSIONS: The results of our study show that in habitual smokers PHC (PFA-100) and the capability of platelets to react upon agonist stimulation in aggregation assays is not significantly influenced or increased compared to healthy nonsmokers. However, an immediate effect of cigarette smoking cannot be excluded.

Adult↗

Influence of preharvest tumor cell contamination in bone marrow or blood does not predict resultant tumor cell contamination of granulocyte colony-stimulating factor mobilized stem cells.

Tumor cell contamination of stem cell collections harvested from breast cancer patients is a common phenomenon described by several investigators but with findings that vary among reports. Although so-called co-mobilization of these cells has been hypothesized, the origin of tumor cell contamination in stem cells is still unknown. A total of 47 G-CSF mobilized stem cell grafts from patients with nodal-positive (n = 30), chemosensitive metastatic (n = 11), and 5 women with inflammatory breast cancer were evaluated for cancer cells by immunocytochemistry. Additionally, 40 bone marrow aspirations and 23 peripheral blood samples collected prior to apheresis and after one to two cycles of conventional chemotherapy were available for examination. Tumor cell contamination of leukapheresis correlated best with preharvest blood state. This was valid when the nominal (positive/negative) presence of tumor cells in blood was compared to the nominal presence of tumor cells in apheresis samples and when the it was correlated to the tumor cell load of apheresis samples (TCL = tumor cells per 10(6) nucleated cells investigated). The correlation between blood and stem cells was better (nominal and quantitative) than that between marrow and stem cells, despite the larger sample size of marrow aspirations. The presence or absence of cancer cells in apheresis samples could not be safely predicted by the presence or absence of tumor cells in marrow or blood alone. Diagnostic specificity seems to improve from a combination of results from marrow and blood analysis. No correlation was found in quantitative analysis of tumor cell contamination between marrow and blood. In conclusion, the results suggest that blood and bone marrow represent different compartments for epithelial cancer cells and that contaminating tumor cells in stem cell harvests may be derived from the blood and/or marrow compartment. The tumor cell contamination of a stem cell harvest cannot be safely predicted by a preceding blood or marrow analysis.

Bone Marrow↗

Disseminated breast cancer cells prior to and after high-dose therapy.

Women with breast cancer in a distinct stage of disease can benefit from high-dose therapy (HDT) with autologous stem cell support; however, a significant number of these patients relapse despite this intensive treatment. This study investigates the persistence of malignancy on the single-cell level. A total of 194 data sets consisting of bone marrow and blood samples obtained prior to and after HDT and of aliquots of apheresis products were searched with immunocytochemistry and reverse transcriptase polymerase chain reaction (RT-PCR) for disseminated cancer cells. Presence of cancer cells in the marrow is frequent prior to and after HDT, but HDT reduces the amount of malignant cells in marrow significantly. In contrast, there was no effect on the number of circulating cancer cells. Reinfusion of contaminated apheresis products was surprisingly associated with a low number of malignant cells in bone marrow after HDT and vice versa. The impact of disseminated tumor cells in bone marrow, apheresis, and peripheral blood on disease-free survival after HDT could be investigated in a total of 165 samples. Surprisingly, neither the presence of tumor cells in marrow or blood nor in apheresis was associated with a bad prognosis in Kaplan-Meyer survival analysis. These results suggest that apheresis products and bone marrow should be regarded as different biological compartments for epithelial cancer cells. It can be concluded that complete elimination of disseminated cancer cells by HDT is not always possible. The theory of reinduction of metastatic breast cancer by accidentally reinfused contaminants is not supported by this study so far. However, further research is necessary to identify distinct cell populations with the potentially capacity to metastasize.

Antineoplastic Combined Chemotherapy Protocols↗

Xenon does not affect human platelet function in vitro.

We sought to determine whether xenon affects platelet glycoprotein expression and platelet-related hemostasis in vitro at a clinically relevant concentration. Human whole blood was stimulated with either adenosine diphosphate or the thrombin receptor agonist peptide (TRAP)-6 after incubation with 65% xenon. Halothane at 2 minimum alveolar anesthetic concentration was used as a positive control. Platelet function and activation were evaluated with two-color flow cytometry. The expression of the platelet glycoproteins GPIIb/IIIa, GPIb, and P selectin were detected with fluorochrome-conjugated monoclonal antibodies. In vitro measurement of platelet-related hemostasis under conditions of high shear stress was performed in citrated whole blood with a platelet function analyzer (PFA-100((R))) by using collagen/epinephrine and collagen/adenosine diphosphate cartridges. Xenon did not affect basal or agonist-induced expression of platelet membrane glycoproteins, activation-dependent conformational changes of the GPIIb/IIIa receptor, expression of P selectin, or PFA closure times. In contrast, halothane reduced TRAP-6-induced activation of the GPIIb/IIIa complex. Furthermore, collagen/epinephrine-induced PFA closure time was significantly prolonged. These results demonstrate that xenon does not affect the unstimulated or agonist-induced platelet glycoprotein expression, activation of GPIIb/IIIa, or platelet-related hemostasis.

Anesthetics, Inhalation↗

In vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity.

Coronary artery stents can induce platelet activation by shear forces, contact to the biomaterial, and release of metal ions. This activation is one important trigger for thrombosis. Coating of stents is a possible approach to prevent this side effect. The purpose of this study was to evaluate in vitro the biocompatibility of stents coated with diamond-like carbon (DLC). Semiquantitative energy-dispersive X-ray microanalyses showed a complete coverage of the DLC stents. Flow cytometric analyses revealed a significantly higher increase of mean channel fluorescence intensity for the activation-dependent antigens CD62p and CD63 in non-coated compared to DLC-coated stents (p<0.05). Atomic adsorption spectrophotometry analyses revealed a significant release of nickel and chromium metal ions by non-coated stents over a storage period of 96 hours in human plasma (p<0.05). In contrast, only minimal concentrations of released ions could be detected in the case of DLC-coated stents. Similar observations were made with inductively coupled plasma mass spectrometry analyses. Here, high concentrations of molybdenum and manganese ions were released from non-coated stents (p<0.05), while release of these ions from DLC-coated stents was virtually undetectable (p=0.1 for molybdenum and p=0.4 for manganese). Coating of intracoronary stents with diamond-like carbon significantly improves biocompatibility. This biocompatible coating may therefore contribute to a reduction in thrombogenicity.

Alloys↗

Cytomegalovirus cultured from different major leukocyte subpopulations: association with clinical features in CMV immunoglobulin G-positive renal allograft recipients.

Cytomegalovirus (CMV) cultured from peripheral blood mononuclear cells (PBMCs) was shown to be associated more closely with clinical manifestations than infectious CMV in polymorphonuclear leukocytes (PMNLs) of renal allograft recipients with secondary CMV infection. Shell vial culture was carried out with ficoll-purified PBMCs and PMNLs of 71 CMV IgG-positive patients after kidney transplantation. Thirty-six patients experienced active CMV infections. Of these, 17 developed clinical symptoms. The diagnostic value of PMNLs and PBMCs viremia was determined in comparison to pp65 antigenemia, leukoDNAemia, plasma DNAemia, and detection of cytomegalic endothelial cells. In both PMNLs and PBMCs (with or without detectable endothelial cells), frequencies and levels of viremia were significantly higher among symptomatic patients. Regarding the occurrence of clinical CMV manifestations, the sensitivity of culture from PMNLs and from PBMCs fractions was 100%. Viremia in PBMCs, however, was far more specific (94%) than in PMNLs (74%). Cutoff values established previously for pp65 antigenemia and leukoDNAemia, standard markers in the laboratory, had similar specificity (96% each) to PBMCs viremia, but were less sensitive (88% each). Plasma DNA-emia was both less sensitive (82%) and less specific (69%) than PBMCs viremia. Detection of endothelemia showed maximal specificity (100%), but inferior sensitivity (47%). All patients had PBMCs viremia before the onset of symptoms. In conclusion, infectious CMV present in PBMCs may prove to be a determinant of clinical CMV manifestations in seropositive immunocompromised individuals. Factors involved in PBMCs tropism may help to understand the pathogenetic mechanisms of CMV dissemination in this group of patients.

Cells, Cultured↗

[Flow-cytometric analysis of platelet activation during rotablation].

Acute occlusion and subacute restenosis of the coronary artery are still the limiting factors of the otherwise successful interventional cardiology. Platelets and especially activated platelet populations play a key role concerning these typical and sometimes fatal complications. In this study we used flow-cytometry to determine the influence of the modern interventional technique of rotablation on platelet antigens and their possible alteration. A PTCA control group was included. We analyzed the fluorescence expression of structural antigens CD41a (GPII-IIIa) and CD42b (GPIb-V-IX), and of the activation-dependent antigens CD62p (P-selectin, PADGEM, GMP-140) and CD63 (GP53). Furthermore we analyzed the binding of fibrinogen to the platelet flow-cytometrically. CD41a and CD42b did not show significant alternations in fluorescence before, directly after and thirty minutes after finishing PTCA and rotablation (PTCA: CD41a p=0.8 and 0.9; CD42b p=0.5 and 0.2; rotablation: CD41a p=0.2 and 0.2; CD42b p=0.4 and 0.1). But platelet activation could be detected directly after PTCA and rotablation measuring the mean channel fluorescence intensity (MCFI) of CD62p, CD63 and fibrinogen binding (all p<0.05). Thirty minutes after finishing the procedures there were again significant changes in MCFI in PTCA (CD62p, CD63, fibrinogen binding; all p<0.05), but not in rotablation (CD62p p=0.1; CD63 p=0. 9; fibrinogen binding p=0.5). But MCFI for CD62p and fibrinogen binding in rotablation was higher than in PTCA. The results of our study show that rotablation also induces significant platelet activation that is higher than in PTCA alone. Flow cytometry is a sensitive and specific, multiparametric tool in establishing platelet activation. The individual platelet activation process is part of a complex cascade of events happening in the rotablated coronary segment leading to a vascular-molecular inflammatory process and consecutive clinical problems in some patients.

Angioplasty, Balloon, Coronary↗

Immunomagnetic tumor cell selection--implications for the detection of disseminated cancer cells.

BACKGROUND: The optimal method for the detection of disseminated epithelial cancer cells has not yet been found. The standard method, using immunocytochemistry, offers a sensitivity of up to 10(-6). Molecular methods such as cytokeratin-19 RT-PCR are about 10 times as sensitive, but they are hampered by interference such as illegitimate gene expression. STUDY DESIGN AND METHODS: Immunomagnetic bead selection of epithelial cancer cells using conjugates directed against the human epithelial antigen (HEA) followed by immunocytochemistry testing was investigated in this trial. RESULTS: No cytokeratin-positive cells could be enriched from 56 control samples. In 104 clinical samples of bone marrow aspirations, PBPC collections, and venous blood obtained from breast cancer patients, the cytokeratin-positive rate increased significantly, from 29.9 percent before selection to 54.8 percent after enrichment. Even the yield of detected cancer cells was significantly higher after selection. Up to 2.5 x 10(8) MNCs were easily processed. However, the mean cancer cell recovery after HEA enrichment was only 24.4 percent. Subsequently, selected epithelial cells were successfully immunophenotyped by use of a double-stain technique detecting cytokeratin-positive cells and the urokinase-like plasminogen activator receptor. CONCLUSION: HEA bead selection in combination with the standard immunocytochemistry method is a powerful and specific tool for the detection of disseminated cancer cells without false-positive results. Furthermore, it delivers enough cells for subsequent investigations such as characterization studies.

Antigens, Surface↗

False-positive results of plasma PCR for cytomegalovirus DNA due to delayed sample preparation.

Positive results by cytomegalovirus (CMV) PCR of plasma are considered predictive of active CMV infection in kidney allograft recipients. To assess whether contamination with leukocyte-derived CMV DNA can distort the results, aliquots of whole-blood samples from 60 CMV immunoglobulin G-positive patients with leukocyte CMV DNAemia were stored for up to 24 h at room temperature (RT) and at 4 degrees C before plasma preparation. Native and ultrafiltered plasma samples were tested by CMV and beta-globin PCRs. Among 30 latently infected patients (negative for CMV pp65 antigens), low baseline rates (10%) and levels (median number of copies, 10 [per 10 microl]) of CMV plasma DNAemia in native plasma samples increased significantly over time (after 4 h at RT, 37% [P < 0.001]; median number of copies, 45 [P < 0.001]). Similar effects were found during storage at 4 degrees C. Ultrafiltration reduced the levels of CMV plasma DNAemia, but by 6 h of storage the levels were significantly elevated as well. CMV and beta-globin DNA kinetics in plasma were parallel. In contrast, 30 actively infected patients (pp65 positive) had high baseline rates (87% in native samples) and levels (median number of copies, 75) of CMV plasma DNAemia. No significant effects of storage or ultrafiltration and no concordance with beta-globin DNA kinetics were seen. In conclusion, delayed preparation of plasma samples bears a significant risk of false-positive CMV PCR results, probably due to leukocyte lysis. This has important implications in the clinical setting and for PCR standardization.

Blood Specimen Collection↗

Extracorporeal plateletpheresis induces the interaction of activated platelets with white blood cells.

BACKGROUND AND OBJECTIVES: In this study we investigated whether platelet activation during apheresis results in the binding of platelets to white blood cells. MATERIAL AND METHODS: Analysis of platelet-leukocyte interaction was performed using multiparameter, three-color flow cytometry. RESULTS: Over the duration of the procedure, there was an increase in the surface expression of CD62p (P-selectin) and CD63 (p<0.05), and also in the binding of platelets to monocytes (p<0.05), neutrophilic granulocytes (p<0.05) and to CD3+ cells (initially to a low degree; p<0.05). Platelet binding to CD19+ cells did not change significantly. CONCLUSION: This study demonstrates that platelets become activated during apheresis and that following this process, interaction with monocytes and neutrophilic granulocytes occurs.

Adult↗

Efficacy of further attempts to mobilize CD34+ peripheral stem cells with alternative procedures after primary failure.

19 patients who failed the target collection of at least 2.5 x 10(6) CD34+ cells/kg underwent further mobilization procedures either with granulocyte-colony-stimulating factor (G-CSF) alone after failure to chemotherapy plus G-CSF (group 1), or with chemotherapy plus G-CSF (group 2), or with high-dose G-CSF (24 microg/kg) alone (group 3) after failure to respond to standard dose of G-CSF (10 microg/kg) alone. In all groups, an increase in median CD34+ cell yield could be observed following alternative procedures (1.1- to 1.9 x 10(6) kg; p = 0.02). The highest increase in CD34+ cell harvest was achieved in group 1 (0.85 to 2.2 x 10(6) kg), followed by group 2 (1. 2 to 1.7) and group 3 (1.0 to 1.4), but without statistically significant difference between the mobilization technologies. All patients with more than 1.0 x 10(6) CD34+ cells/kg in the first apheresis procedure reached the overall target of 2.5 x 10(6) CD34+ cells/kg after a second or subsequent mobilization procedure. In contrast, only 3 of 8 patients (37%) with less than 1.0 x 10(6) CD34+ cells in the first harvest could reach the target of 2.5 x 10(6) CD34+ cells after further mobilization attempts.

Adolescent↗

Flow cytometry: the standard for monitoring the onset of apheresis and for the evaluation of stem and progenitor cell graft quality.

Several high-quality protocols exist that describe the methodological and technical aspects of the flow cytometric analyses of stem and progenitor cells. In addition, recent advances in automation and quantitative analyses show promising results. For further improvement of the test quality and more objective control, internal as well as external quality control is mandatory. In addition, cost aspects move into the focus of interest and have to be considered. Alternative methods such as volumetric capillary cytometry or haematological analyzers are of limited use for stem and progenitor cell analyses. Currently, flow cytometry represents the gold standard for monitoring the onset of apheresis and to evaluate the quality of stem and progenitor cell grafts. In the near future, only in vitro diagnostics that are CE-labelled or FDA-approved should be used for these analyses.

Blood Component Removal↗

A randomized comparison of once versus twice daily recombinant human granulocyte colony-stimulating factor (filgrastim) for stem cell mobilization in healthy donors for allogeneic transplantation.

To evaluate the schedule dependency of granulocyte colony-stimulating factor (G-CSF) (filgrastim) for stem cell mobilization, we conducted a randomized comparison in 50 healthy donors, with one subcutaneous daily injection of 10 microg/kg G-CSF (n = 25) compared with twice injections daily of 5 microg/kg G-CSF (n = 25). The two groups were well balanced for age, body weight and sex. G-CSF application was performed on an out-patient basis and leukapheresis was started in all donors on day 5. The most frequent side-effects of G-CSF were mild to moderate bone pain (88%), mild headache (72%), mild fatigue (48-60%) and nausea (8%) without differences between the two groups. The CD34(+) cell count in the first apheresis was 5.4 x 10(6)/kg donor weight (range 2.8-13.3) in the 2 x 5 microg/kg group compared with 4.0 x 10(6)/kg (range 0.4-8.8) in the 1 x 10 microg/kg group (P = 0.007). The target of collecting > 3.0 x 10(6) CD34(+) cells/kg donor weight with one apheresis procedure was achieved in 24/25 (96%) donors in the 2 x 5 microg/kg group and in 17/25 (68%) donors in the 1 x 10 microg/kg group. The target of collecting > 5.0 x 10(6) CD34(+) cells/kg in the first apheresis was achieved in 64% in the 2 x 5 microg/kg group, but in only 36% in the 1 x 10 microg/kg group. The progenitor cell assay for granulocyte-macrophage colony-forming units (CFU-GM) and erythroid burst-forming units (BFU-E) was higher in the 2 x 5 microg/kg group than in the 1 x 10 microg/kg group (7.0 vs. 3.5 x 10(5)/kg, P = 0.01; 6.6 vs. 5.0 x 10(5)/kg; P = 0.1). Administering G-CSF (filgrastim) at a dosage of 5 microg/kg twice daily rather than 10 microg/kg once daily is recommended; this leads to a higher CD34(+) cell yield and requires fewer apheresis procedures without increasing toxicity or cost.

Adult↗