Cardiac and hemodynamic effects of hemodialysis and ultrafiltration.

Imbalance between cardiac oxygen supply and demand may trigger cardiac events in already vulnerable hemodialysis (HD) patients. We studied the effect of ultrafiltration (UF) and HD in nine chronic HD patients by continuously measuring blood volume (BV; by Critline), blood pressure (BP; by Portapres), and changes in hemodynamics (Modelflow) during isolated UF (iUF) of 500 mL in 30 minutes and subsequent HD combined with UF (HD + UF). Aortic pressure was reconstructed from finger pressure. Changes in cardiac oxygen supply were assessed by calculating the area under the aortic pressure curve during diastole (diastolic pressure time index [DPTI]). Changes in cardiac oxygen demand were assessed by calculating systolic pressure time index (SPTI). BV decreased 4.0% +/- 1.8% during UF and 7.3% +/- 3.3% during HD + UF (both P < 0.01). Systolic BP did not change; diastolic and mean BP increased 11 +/- 7.4 and 11 +/- 8.4 mm Hg during iUF, respectively (both P < 0.01), and stabilized during HD + UF. Overall pulse pressure decreased 19 +/- 11.1 mm Hg (P < 0.01). Heart rate increased 13 +/- 11 beats/min (P < 0.01) and systemic vascular resistance increased 59% +/- 51% (P < 0. 01), whereas stroke volume and cardiac output (CO) decreased by 40% +/- 17% and 30% +/- 13%, respectively (both P < 0.01). Both cardiac oxygen supply (DPTI) and demand (SPTI) increased during iUF, and both decreased during HD + UF. By the end of the procedure, DPTI/SPTI ratio had increased 9% +/- 8% (P < 0.05). Changes in CO correlated closely to changes in BV. Despite large changes in hemodynamics during uncomplicated UF and HD, the balance between cardiac oxygen supply and demand (DPTI/SPTI ratio) did not decrease, but improved slightly.

Adult

Estimation of beat-to-beat changes in stroke volume from arterial pressure: a comparison of two pressure wave analysis techniques during head-up tilt testing in young, healthy men.

OBJECTIVE: The aim of this study was to compare beat-to-beat changes in stroke volume (SV) estimated by two different pressure wave analysis techniques during orthostatic stress testing: pulse contour analysis and Modelflow, i.e., simulation of a three-element model of aortic input impedance. METHODS: A reduction in SV was introduced in eight healthy young men (mean age, 25; range, 19-32 y) by a 30-minute head-up tilt maneuver. Intrabrachial and noninvasive finger pressure were monitored simultaneously. Beat-to-beat changes in SV were estimated from intrabrachial pressure by pulse contour analysis and Modelflow. In addition, the relative differences in Modelflow SV obtained from intrabrachial pressure and noninvasive finger pressure were assessed. RESULTS: Beat-to-beat changes in Modelflow SV from intrabrachial pressure were comparable with pulse contour measures. The relative difference between the two methods amounted to 0.1+/-1% (mean +/- SEM) and was not dependent on the duration of tilt. The difference between Modelflow applied to intrabrachial pressure and finger pressure amounted to -2.7+/-1.3% (p = 0.04). This difference was not dependent on the duration of tilt or level of arterial pressure. CONCLUSIONS: Based on different mathematical models of the human arterial system, pulse contour and Modelflow compute similar changes in SV from intrabrachial pressure during orthostatic stress testing in young healthy men. The magnitude of the difference in SV derived from intrabrachial and finger pressure may vary among subjects; Modelflow SV from noninvasive finger pressure tracks fast and brisk changes in SV derived from intrabrachial pressure.

Adult

Effects of arteriovenous fistulas on cardiac oxygen supply and demand.

BACKGROUND: Arteriovenous (AV) fistulas used for hemodialysis access may affect cardiac load by increasing the preload while decreasing the afterload. In dogs, AV fistulas have also been shown to affect coronary perfusion negatively. We investigated the net effect of AV fistulas on cardiac oxygen supply and demand. METHODS: Aortic pressure waves were reconstructed from finger pressure recordings obtained on the nonfistula arm using a wave-form filter. Changes in systolic, mean, and diastolic aortic pressure were calculated, together with changes in heart rate (HR), stroke volume (SV), cardiac output (CO), and systemic vascular resistance (SVR) during a 60-second compression of AV fistulas in 10 patients. Changes in cardiac supply and demand were estimated by calculating the area under the aortic pressure curve during diastole [diastolic pressure time index (DPTI)] and systole [systolic pressure time index (SPTI)], respectively. RESULTS: During fistula compression, systolic, mean and diastolic pressure increased by 4.2 +/- 4.3, 2.6 +/- 3.0, and 2.8 +/- 2.9 mm Hg (mean +/- SD, all P < 0.05). The HR decreased by 3.8 +/- 2.5 beats per minute (P < 0.01), and SV decreased 3.7 +/- 6.1% (NS). CO decreased 9.4 +/- 8.6%, and SVR increased 14.3 +/- 11.7% (both P < 0.05). The SPTI increased by 1.5 +/- 1.5 mm Hg.sec (P < 0.01), and the DPTI increased by 7.6 +/- 8.1 mm Hg.sec (14.8% increase, P < 0.05) during compression. The ratio of supply and demand (DPTI/SPTI) improved by 13.5 +/- 13.0% (P < 0.01) when the fistula was compressed. CONCLUSION: AV fistulas have a small effect on left ventricular oxygen demand, but decrease cardiac oxygen supply considerably.

Adult

Continuous cardiac output in septic shock by simulating a model of the aortic input impedance: a comparison with bolus injection thermodilution.

BACKGROUND: To compare continuous cardiac output obtained by simulation of an aortic input impedance model to bolus injection thermodilution (TDCO) in critically ill patients with septic shock. METHODS: In an open study, mechanically ventilated patients with septic shock were monitored for 1 (32 patients), 2 (15 patients), or 3 (5 patients) days. The hemodynamic state was altered by varying the dosages of dopamine, norepinephrine, or dobutamine. TDCO was estimated 189 times as the series average of four automated phase-controlled injections of iced 5% glucose, spread equally over the ventilatory cycle. Continuous model-simulated cardiac output (MCO) was computed from radial or femoral artery pressure. On each day, the first TDCO value was used to calibrate the model. RESULTS: TDCO ranged from 4.1 to 18.2 l/min. The bias (mean difference between MCO and TDCO) on the first day before calibration was -1.92 +/- 2.3 l/min (mean +/- SD; n = 32; 95% limits of agreement, -6.5 to 2.6 l/min). The bias increased at higher levels of cardiac output (P < 0.05). In 15 patients studied on two consecutive days, the precalibration ratio TDCO:MCO on day 1 was 1.39 +/- 0.28 (mean +/- SD) and did not change on day 2 (1.39 +/- 0.34). After calibration, the bias was -0.1 +/- 0.8 l/min with 82% of the comparisons (n = 112) < 1 l/min and 58% (n = 79) < 0.5 l/min, and independent of the level of cardiac output. CONCLUSIONS: In mechanically ventilated patients with septic shock, changes in bolus TDCO are reflected by calibrated MCO over a range of cardiac output values. A single calibration of the model appears sufficient to monitor continuous cardiac output over a 2-day period with a bias of -0.1 +/- 0.8 l/min.

Adult

Broad-band spectral analysis of 24 h continuous finger blood pressure: comparison with intra-arterial recordings.

The present study compares the spectral characteristics of 24-h blood pressure variability estimated invasively at the brachial artery level with those estimated by measurement of blood pressure at the finger artery using the non-invasive Portapres device. Broad-band spectra (from 3x10(-5) to 0.5 Hz) were derived from both finger and intra-brachial pressures recorded simultaneously for 24 h in eight normotensive and twelve hypertensive ambulant subjects. At frequencies lower than 0.07 Hz, higher spectral estimates were obtained by Portapres than by intra-brachial measurements. The maximum overestimation occurred in systolic pressure at around 10(-2) Hz, where the amplitude of the oscillations was two times greater when measured by Portapres. A less pronounced overestimation was found for diastolic pressures. The maximum overestimation was greater during daytime than during night-time. At around 0.1 Hz, invasive and non-invasive spectra were similar. At the respiratory frequencies (0.15-0.50 Hz), the power spectra were overestimated by Portapres during daytime, and underestimated at night. These results provide reference information for the correct interpretation of Portapres data in the estimation of 24-h blood pressure spectral power.

Adult

Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress.

The relationship between aortic flow and pressure is described by a three-element model of the arterial input impedance, including continuous correction for variations in the diameter and the compliance of the aorta (Modelflow). We computed the aortic flow from arterial pressure by this model, and evaluated whether, under orthostatic stress, flow may be derived from both an invasive and a non-invasive determination of arterial pressure. In 10 young adults, Modelflow stroke volume (MFSV) was computed from both intra-brachial arterial pressure (IAP) and non-invasive finger pressure (FINAP) measurements. For comparison, a computer-controlled series of four thermodilution estimates (thermodilution-determined stroke volume; TDSV) were averaged for the following positions: supine, standing, head-down tilt at 20 degrees (HDT20) and head-up tilt at 30 degrees and 70 degrees (HUT30 and HUT70 respectively). Data from one subject were discarded due to malfunctioning thermodilution injections. A total of 155 recordings from 160 series were available for comparison. The supine TDSV of 113+/-13 ml (mean+/-S.D.) dropped by 40% to 68+/-14 ml during standing, by 24% to 86+/-12 ml during HUT30, and by 51% to 55+/-15 ml during HUT70. During HDT20, TDSV was 114+/-13 ml. MFSV for IAP underestimated TDSV during HDT20 (-6+/-6 ml; P<0.05), but that for FINAP did not (-4+/-7 ml; not significant). For HUT70 and standing, MFSV for IAP overestimated TDSV by 11+/-10 ml (HUT70; P<0.01) and 12+/-9 ml (standing; P<0.01). However, the offset of MFSV for FINAP was not significant for either HUT70 (3+/-8 ml) or standing (3+/-9 ml). In conclusion, due to orthostasis, changes in the aortic transmural pressure may lead to an offset in MFSV from IAP. However, Modelflow correctly calculated aortic flow from non-invasively determined finger pressure during orthostasis.

Adult

Fifteen years experience with finger arterial pressure monitoring: assessment of the technology.

We review the Finapres technology, embodied in several TNO-prototypes and in the Ohmeda 2300 and 2300e Finapres NIBP. Finapres is an acronym for FINger Arterial PRESsure, the device delivers a continuous finger arterial pressure waveform. Many papers report on the accuracy of the device in comparison with intra-arterial or with noninvasive but intermittent blood pressure measurements. We compiled the results of 43 such papers and found systolic, diastolic and mean accuracies, in this order, ranging from -48 to 30 mmHg, from -20 to 18 mmHg, and from -13 to 25 mmHg. Weighted for the number of subjects included pooled accuracies were -0.8 (SD 11.9), -1.6 (8.3) and -1.6 (7.6) mmHg respectively. Subdividing the pooled group according to criteria such as reference blood pressure, place of application, and prototype or commercial device we found no significant differences in mean differences or SD. Measurement at the finger allows uninterrupted recordings of long duration. The transmission of the pressure pulse along the arm arteries, however, causes distortion of the pulse waveform and depression of the mean blood pressure level. These effects can be reduced by appropriate filtering, and upper arm 'return-to-flow' calibration to bring accuracy and precision within AAMI limits. For the assessment of beat-to-beat changes in blood pressure and assessment of blood pressure variability Finapres proved a reliable alternative for invasive measurements when mean and diastolic pressures are concerned. Differences in systolic pressure are larger and reach statistical significance but are not of clinical relevance. Finger arteries are affected by contraction and dilatation in relation to psychological and physical (heat, cold, blood loss, orthostasis) stress. Effects of these phenomena are reduced by the built-in Physiocal algorithm. However, full smooth muscle contraction should be avoided in the awake patient by comforting the patient, and covering the hand. Arterial state can be monitored by observing the behaviour of the Physiocal algorithm. We conclude that Finapres accuracy and precision usually suffice for reliable tracking of changes in blood pressure. Diagnostic accuracy may be achieved with future application of corrective measures.

Blood Pressure Monitoring, Ambulatory

Estimation of blood pressure variability from 24-hour ambulatory finger blood pressure.

Portapres is a noninvasive, beat-to-beat finger blood pressure (BP) monitor that has been shown to accurately estimate 24-hour intra-arterial BP at normal and high BPs. However, no information is available on the ability of this device to accurately track ambulatory BP variability. In 20 ambulatory normotensive and hypertensive subjects, we measured 24-hour BP by Portapres and through a brachial artery catheter. BP and pulse interval variabilities were quantified by (1) the SDs of the mean values (overall variability) and (2) spectral power, computed either by fast Fourier transform and autoregressive modeling of segments of 120-second duration for spectral components from 0.025 to 0.50 Hz or in a very low frequency range (between 0.00003 and 0.01 Hz) by broadband spectral analysis. The 24-hour SD of systolic BP obtained from Portapres (24+/-2 mm Hg) was greater than that obtained intra-arterially (17+/-1 mm Hg, P<0.01), but the overestimation was less evident for diastolic (3+/-1 mm Hg, P<0.01) and mean (3+/-1 mm Hg, P<0.01) BP. The BP spectral power <0.15 Hz was also overestimated by Portapres more for systolic than for diastolic and mean BPs; similar findings were obtained by the fast Fourier transform, the autoregressive approach, and focusing on the broadband spectral analysis. BP spectral power >0.15 Hz obtained by the Portapres was similar during the day but lower during the night when compared with those obtained by intra-arterial recordings (P<0.01). No differences were observed between Portapres and intra-arterial recordings for any estimation of pulse interval variabilities. The overestimation of BP variability by Portapres remained constant over virtually the entire 24-hour recording period. Thus, although clinical studies are still needed to demonstrate the clinical relevance of finger BP variability, our study shows that Portapres can be used with little error to estimate 24-hour BP variabilities if diastolic and mean BPs are used. For systolic BP, the greater error can be minimized by using correction factors.

Adult

The Valsalva manoeuvre as a cardiovascular reflex test in healthy children and teenagers.

The objective of this study was to determine whether the Valsalva manoeuvre is applicable as a test for neurocardiovascular control in healthy children and teenagers. Sixty-eight 6- to 16-year-old children and teenagers performed two Valsalva manoeuvres in the sitting position. They were instructed to maintain airway pressure (strain) for 15 s at 30 mmHg in the first and at 40 mmHg in the second manoeuvre. Finger arterial pressure and heart rate were monitored continuously. In three of the 68 subjects it was not possible to obtain a reliable blood pressure recording due to movements of the finger and/or hand. Only 10 subjects were able to reach a strain of 30 mmHg and to maintain this strain constant during 15 s; in the others the level or the duration of the strain varied substantially. Nine subjects kept strain at 40 mmHg during 15 s. With a Valsalva manoeuvre of 30 mmHg, control values of blood pressure and heart rate in the last 5 s prior to the manoeuvre increased in 11 subjects. Notwithstanding the large range in straining (15-55 mmHg), on visual inspection blood pressure and heart rate responses known from studies in adults could be recognized in 57 of the 65 subjects. In the other eight subjects atypical heart rate responses were observed. Forty-four of the 65 subjects could perform a Valsalva manoeuvre with a higher airway pressure compared to the first manoeuvre: range 35-55 mmHg. The higher airway pressure resulted in more pronounced blood pressure and heart rate responses. There was no correlation between age and gender versus airway pressure. It was concluded that the Valsalva manoeuvre generated blood pressure responses as found in adults. Heart rate responses were sometimes atypical, and needed underlying blood pressure measurement for full interpretation. For quantitative analysis the test was hampered by the inability of the majority of our young subjects to produce the exact strain during the 15-s period. Qualitatively, however, the Valsalva manoeuvre seems applicable as a cardiovascular reflex test to assess neurocardiovascular control in children and teenagers.

Adolescent

Compressed storage of arterial pressure waveforms by selection of significant points.

Continuous records of arterial blood pressure can be obtained non-invasively with Finapres, even for periods of 24 hours. Increasingly, storage of such records is done digitally, requiring large disc capacities. It is therefore necessary to find methods to store blood pressure waveforms in compressed form. The method of selection of significant points known from ECG data compression is adapted. Points are selected as significant wherever the first derivative of the pressure wave changes sign. As a second stage recursive partitioning is used to select additional points such that the difference between the selected points, linearly interpolated, and the original curve remains below a maximum. This method is tested on finger arterial pressure waveform epochs of 60 s duration taken from 32 patients with a wide range of blood pressures and heart rates. An average compression factor of 4.6 (SD 1.0) is obtained when accepting a maximum difference of 3 mmHg. The root mean squared error is 1 mmHg averaged over the group of patient waveforms. Clinically relevant parameters such as systolic, diastolic and mean pressure are reproduced with an offset error of less than 0.5 (0.3) mmHg and scatter less than 0.6 (0.1) mmHg. It is concluded that a substantial compression factor can be achieved with a simple and computationally fast algorithm and little deterioration in waveform quality and pressure level accuracy.

Blood Pressure

Models of brachial to finger pulse wave distortion and pressure decrement.

OBJECTIVE: To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. METHODS: Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by the Finapres technique in 53 adult human subjects. Mean pressure was subtracted from each pressure waveform and Fourier analysis applied to the pulsations. A distortion model was estimated for each subject and averaged over the group. The average inverse model was applied to the full finger pressure waveform. The pressure decrement was modelled by multiple regression on finger systolic and diastolic levels. RESULTS: Waveform distortion could be described by a general, frequency dependent model having a resonance at 7.3 Hz. The general inverse model has an anti-resonance at this frequency. It converts finger to brachial pulsations thereby reducing average waveform distortion from 9.7 (s.d. 3.2) mmHg per sample for the finger pulse to 3.7 (1.7) mmHg for the converted pulse. Systolic and diastolic level differences between finger and brachial arterial pressures changed from -4 (15) and -8 (11) to +8 (14) and +8 (12) mmHg, respectively, after inverse modelling, with pulse pressures correct on average. The pressure decrement model reduced both the mean and the standard deviation of systolic and diastolic level differences to 0 (13) and 0 (8) mmHg. Diastolic differences were thus reduced most. CONCLUSION: Brachial to finger pulse wave distortion due to wave reflection in arteries is almost identical in all subjects and can be modelled by a single resonance. The pressure decrement due to flow in arteries is greatest for high pulse pressures superimposed on low means.

Adult

Variability of near-fainting responses in healthy 6-16-year-old subjects.

1. Fainting is a common phenomenon in young subjects, but the final events before the actual faint are not well known. The aim of the present study was to study the inter-individual variability of haemodynamic events associated with near-fainting in children and teenagers. 2. Sixty-eight healthy subjects (aged 6-16 years) performed a 70 degrees tilt-up test with intravascular instrumentation for 5 min. Responses in 29 near-fainting subjects were analysed and compared with 39 non-fainting subjects. Arterial pressure was measured by Finapres. Left ventricular stroke volume was computed from the pressure pulsation waveform. 3. Inability to maintain vasomotor tone was the mechanism underlying near-fainting in the vast majority of near-fainting subjects. The three classical haemodynamic responses (vasovagal, vasodepressor and vagal) could be recognized, but large individual differences were found. After tilt back, blood pressure in near-fainters showed a mirror response to the stage before tilt-back; blood pressure gradually increased and was normal at 1 min after tilt-back. 4. The variability in haemodynamic responses on approach of an orthostatic faint is wide in the young.

Adolescent

Aortic and peripheral blood pressure during isometric and dynamic exercise.

The purpose of this study was to compare aortic blood pressure (AOR) to peripheral measurements by the Riva-Rocci/Korotkov (RRK) and Finapres continuous finger pressure (FIN) methods during dynamic and static exercise. A tip manometer was introduced in the ascending aorta after coronary angiography in 7 cardiac patients with good exercise capability. Static exercise was of moderate intensity and led to an increase of average diastolic and systolic AOR of 20 and 18 mmHg, respectively. The corresponding RKK values were 20 and 30 mmHg and the FIN values were 16 and 14 mmHg, respectively. In maximal cycle ergometry the discrepancies were larger, especially in the 4 subjects who reached 80% or more of predicted maximal work load. Diastolic and systolic increases in AOR in these 4 subjects were 12 and 38 mmHg, respectively. The RRK values were 17 and 76 mmHg. Increases in FIN values of 17 and 74 mmHg for diastolic and systolic measurements, respectively, were found. The peripheral FIN and RRK measurements give a systolic increase that is twice as large as that for AOR. It is concluded that RRK and FIN greatly overestimate the load to the cardiovascular system in dynamic exercise. When the cardiovascular load is estimated by the rate-pressure product, RRK produces an increase of 197%, FIN of 181%, while AOR gives an increase of only 133%. This suggests that the present criteria for blood pressure in exercise testing should be critically examined.

Adult

Reconstruction of brachial artery pressure from noninvasive finger pressure measurements.

BACKGROUND: Pulse wave distortions, mainly caused by reflections, and pressure gradients, caused by flow in the resistive vascular tree, may cause differences between finger and brachial artery pressures. These differences may limit the use of finger pressure measurements. We investigated whether brachial artery pressure waves could be reconstructed from finger pressure measurements by correcting for the pressure gradient in addition to correction for pulse wave distortion with a previously described filter. METHODS AND RESULTS: Finger artery pressure (with Finapres), intra-arterial brachial artery pressure (BAP), Riva-Rocci/ Korotkoff (RRK), oscillometric, and return-to-flow (RTF) measurements were simultaneously performed in 57 healthy elderly subjects and patients with vascular disease and/or hypertension. A generalized waveform filter was used to correct for pulse wave distortions. Correction equations for the pressure gradient, based on finger pressure, RRK, RTF, or oscillometric measurements, were obtained in 28 randomly selected subjects and tested in 29. Before reconstruction, Finapres underestimated mean and diastolic BAP (finger pressure minus BAP: systolic, -3.2 +/- 16.9 mm Hg; mean, -13.0 +/- 10.5 mm Hg; diastolic, -8.4 +/- 9.0 mm Hg [mean +/- SD]). After filtering, reconstructed BAP waves were similar to actual BAP in shape but not in pressure level. Optimal correction for the pressure gradient with an equation based on RTF measurements reduced the pressure differences to meet American Association for the Advancement of Medical Instrumentation criteria (reconstructed finger pressure minus BAP: systolic, 3.7 +/- 7.0 mm Hg; mean, 0.7 +/- 4.6 mm Hg; and diastolic, 1.0 +/- 4.9 mm Hg). CONCLUSIONS: BAP waves can be reconstructed from noninvasive finger pressure registrations when finger pressure waves are corrected for pulse wave distortion and individual pressure gradients.

Adult

Finger arterial versus intrabrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects.

1. The aims of this study were to determine the clinical feasibility of continuous, non-invasive Finapres recordings as a replacement for intrabrachial pressure during a 30 min head-up tilt, and the reliability of continuous cardiac output computation by pulse contour analysis from the finger arterial versus the brachial waveform. 2. In eight healthy subjects a 30 min 70 degrees passive head-up tilt was performed. Finger arterial (FINAP) and intrabrachial (IAP) pressures were measured simultaneously. Beat-to-beat changes in stroke volume were computed using a pulse contour algorithm. 3. Accuracy (the group-averaged FINAP-IAP difference) and precision (the SD of the difference) of Finapres measurements were 4 and 9 mmHg for systolic blood pressure, -5 and 9 mmHg for mean blood pressure and -5 and 9mmHg for diastolic blood pressure. 4. The time course of the FINAP-IAP differences during head-up tilt showed a linear trend (P < 0.001 for all pressure levels). Averaged for the group, the difference increased 7 mmHg for mean blood pressure. The difference in stroke volume computed from FINAP and IAP was 0.3 +/- 5% (mean +/- SD), and independent of the duration of the tilt (P > 0.05). This difference did not change at low blood pressure levels (0.5 +/- 6%). 5. The qualitative performance of the Finapres allows it to be used in the clinical setting as a monitor of sudden changes in blood pressure induced by a 30 min head-up tilt. Relative changes in stroke volume, as obtained by pulse contour analysis of the finger arterial waveform, closely follow intrabrachial values during long-duration head-up tilt and associated arterial hypotension.

Adult

Single injection thermodilution. A flow-corrected method.

BACKGROUND: Application of the Stewart-Hamilton equation in the thermodilution technique requires flow to be constant. In patients in whom ventilation of the lungs is controlled, flow modulations may occur leading to large errors in the estimation of mean cardiac output. METHODS: To eliminate these errors, a modified equation was developed. The resulting flow-corrected equation needs an additional measure of the relative changes of blood flow during the period of the dilution curve. Relative flow was computed from the pulmonary artery pressure with use of the pulse contour method. Measurements were obtained in 16 patients undergoing elective coronary artery bypass surgery. In 11 patients (group A), pulmonary artery pressure was measured with a catheter tip transducer, in a partially overlapping group of 11 patients (group B), it was measured with a fluid-filled system. For reference cardiac output we used the proven method of four uncorrected thermodilution estimates equally spread over the ventilatory cycle. RESULTS: A total of 208 cardiac output estimates was obtained in group A, and 228 in group B. In group B, 48 estimates could not be corrected because of insufficient pulmonary artery pressure waveform quality from the fluid-filled system. Individual uncorrected Stewart-Hamilton estimates showed a large variability with respect to their mean. In group A, mean cardiac output was 5.01 l/min with a standard deviation of 0.53 l/min, or 10.6%. After flow correction, this scatter decreased to 5.0% (P < 0.0001). With no bias, the corresponding limits of agreement decreased from +/- 1.06 to +/- 0.5 l/min after flow correction. In group B, the scatter decreased similarly and the limits of agreement also became +/- 0.5 l/min after flow correction. CONCLUSION: It was concluded that a single thermodilution cardiac output estimate using the flow-corrected equation is clinically feasible. This is obtained at the cost of a more complex computation and an extra pressure measurement, which often is already available. With this technique it is possible to reduce the fluid load to the patient considerably.

Adult

Finapres tracking of systolic pressure and baroreflex sensitivity improved by waveform filtering.

OBJECTIVE: Arterial pressure waveforms distort between brachial and finger arteries, causing differences mainly in systolic pressure. Distortion, reportedly, can be removed by applying a waveform filter to the finger pressure. DESIGN: We analysed the data from two studies that detected discrepancies in systolic tracking between Finapres and brachial pressures. The first set comprised waveforms of seven volunteers during incremental bicycle exercise to exhaustion and the second set comprised waveforms of eight volunteers during increasing phenylephrine infusion. METHODS: We applied the filter and compared 1 min averaged unfiltered and waveform-filtered finger and brachial pressures. RESULTS: During exercise, finger systolic pressure overestimated brachial increasingly, from 7(SD 10) mmHg at rest to 27(17) mmHg at maximal exertion. Differences were reduced by waveform filtering from 3 (SD 9)mmHg at rest to 1 (SD 15)mmHg at maximal exertion. During phenylephrine infusion finger systolic pressure overestimated brachial pressure, but the magnitude of the overestimate decreased from 14 (SD 15)mmHg at baseline to -1(SD 16)mmHg at maximal rate. After waveform filtering overestimation was an almost constant 6(SD 11)mmHg. Median baroreflex sensitivities from brachial, unfiltered and waveform-filtered finger pressure were 5.8, 7.5 and 5.3 ms/mmHg and correlation increased after filtering. The results indicate improved systolic pressure tracking after waveform filtering. CONCLUSIONS: Finger pressure distortion follows a general pattern correctable by waveform filtering. Waveform filtering allows a 'brachial' view to be obtained from Finapres data.

Adolescent

Finger arterial pressure measurement with Finapres.

Finger arterial pressure measurement with Finapres has been available since a decade. Its availability has promoted at least 300 methodological and research papers over these years, outlining the usefulness and the limitations of the method and the device. Finapres is based on the volume clamp method of Peñáz and the Physiocal criteria of Wesseling. Tracking of intraarterial pressure is usually satisfactory even under conditions of strongly changing hemodynamics and high and very low blood pressures. Finapres accuracy is similar to that of other non-invasive methods. Systolic pressure levels scatter more than mean and diastolic levels. One source of error is physiologic and determined by the peripheral measurement site of the finger, causing pulse waveform distortion and a pressure gradient. The Finapres waveform can be filtered, however, to obtain a brachial pressure wave. This decreases systolic scatter under vaso-constrictive drug infusion and dynamic exercise to exhaustion, conditions where precision of systolic tracking has been criticized in the literature. Recently, level correction techniques were found which shift finger pressure up or down based on a regression equation with finger systolic and diastolic pressures. This procedure requires no additional measurements yet improves systolic, diastolic and mean level accuracy and precision remarkably. Finally, we show how to judge the quality of a Finapres recording from the behavior of Physiocal.

Arteries