Finapres tracking of systolic pressure and baroreflex sensitivity improved by waveform filtering.

OBJECTIVE: Arterial pressure waveforms distort between brachial and finger arteries, causing differences mainly in systolic pressure. Distortion, reportedly, can be removed by applying a waveform filter to the finger pressure. DESIGN: We analysed the data from two studies that detected discrepancies in systolic tracking between Finapres and brachial pressures. The first set comprised waveforms of seven volunteers during incremental bicycle exercise to exhaustion and the second set comprised waveforms of eight volunteers during increasing phenylephrine infusion. METHODS: We applied the filter and compared 1 min averaged unfiltered and waveform-filtered finger and brachial pressures. RESULTS: During exercise, finger systolic pressure overestimated brachial increasingly, from 7(SD 10) mmHg at rest to 27(17) mmHg at maximal exertion. Differences were reduced by waveform filtering from 3 (SD 9)mmHg at rest to 1 (SD 15)mmHg at maximal exertion. During phenylephrine infusion finger systolic pressure overestimated brachial pressure, but the magnitude of the overestimate decreased from 14 (SD 15)mmHg at baseline to -1(SD 16)mmHg at maximal rate. After waveform filtering overestimation was an almost constant 6(SD 11)mmHg. Median baroreflex sensitivities from brachial, unfiltered and waveform-filtered finger pressure were 5.8, 7.5 and 5.3 ms/mmHg and correlation increased after filtering. The results indicate improved systolic pressure tracking after waveform filtering. CONCLUSIONS: Finger pressure distortion follows a general pattern correctable by waveform filtering. Waveform filtering allows a 'brachial' view to be obtained from Finapres data.

Adolescent↗

Finger arterial pressure measurement with Finapres.

Finger arterial pressure measurement with Finapres has been available since a decade. Its availability has promoted at least 300 methodological and research papers over these years, outlining the usefulness and the limitations of the method and the device. Finapres is based on the volume clamp method of Peñáz and the Physiocal criteria of Wesseling. Tracking of intraarterial pressure is usually satisfactory even under conditions of strongly changing hemodynamics and high and very low blood pressures. Finapres accuracy is similar to that of other non-invasive methods. Systolic pressure levels scatter more than mean and diastolic levels. One source of error is physiologic and determined by the peripheral measurement site of the finger, causing pulse waveform distortion and a pressure gradient. The Finapres waveform can be filtered, however, to obtain a brachial pressure wave. This decreases systolic scatter under vaso-constrictive drug infusion and dynamic exercise to exhaustion, conditions where precision of systolic tracking has been criticized in the literature. Recently, level correction techniques were found which shift finger pressure up or down based on a regression equation with finger systolic and diastolic pressures. This procedure requires no additional measurements yet improves systolic, diastolic and mean level accuracy and precision remarkably. Finally, we show how to judge the quality of a Finapres recording from the behavior of Physiocal.

Arteries↗

Catheter-manometer system damped blood pressures detected by neural nets.

Degraded catheter-manometer systems cause distortion of blood pressure waveforms, often leading to erroneously resonant or damped waveforms, requiring waveforms quality control. We have tried multilayer perceptron back-propagation trained neural nets of varying architecture to detect damping on sets of normal and artificially damped brachial arterial pressure waves. A second-order digital simulation of a catheter-manometer system is used to cause waveform distortion. Each beat in the waveforms is represented by an 11 parameter input vector. From a group of normotensive or (borderline) hypertensive subjects, pressure waves are used to statistically test and train the neural nets. For each patient and category 5-10 waves are available. The best neural nets correctly classify about 75-85% of the individual beats as either adequate or damped. Using a single majority vote classification per subject per damped or adequate situation, the best neural nets correctly classify at least 16 of the 18 situations in nine test subjects (binomial P = 0.001). More importantly, these neural nets can always detect damping before clinically relevant parameters such as systolic pressure and computed stroke volume are reduced by more than 2%. Neural nets seem remarkably well adapted to solving such subtle problems as detecting a slight damping of arterial pressure waves before it affects waveforms to a clinically relevant degree.

Adult↗

Incidence and hemodynamic characteristics of near-fainting in healthy 6- to 16-year old subjects.

OBJECTIVES: We studied the incidence and hemodynamic characteristics of near-fainting under orthostatic stress in healthy children and teenagers. BACKGROUND: Orthostatic stress testing is increasingly used to identify young subjects with unexplained syncope. However, the associated incidence of syncope and hemodynamic responses in normal young subjects are not well known. METHODS: Eighty-four healthy subjects 6 to 16 years old performed forced breathing, stand-up and 70 degrees tilt-up tests. An intravenous line to sample blood for biochemical assessment of sympathetic function was introduced between the stand-up and tilt-up tests. Finger arterial pressure was measured continuously. Left ventricular stroke volume was computed from the pressure pulsations. RESULTS: Sixteen of the 84 subjects were excluded because of technical problems. The incidence of a near-fainting response in the remaining 68 subjects was 10% (7 of 68) for the stand-up test and 40% (29 of 68) for the tilt-up test. Baseline parasympathetic and sympathetic activity of nonfainting and near-fainting subjects was not different. Near-fainting was characterized by attenuated systemic vasoconstriction and exaggerated tachycardia that occurred as early as 1 min after return to the upright position. On tilt-up, plasma adrenaline levels increased by a factor of 2, with slightly higher increments in the near-fainting subjects. CONCLUSIONS: Inadequate vasoconstriction is the common underlying mechanism of near-fainting in young subjects. The remarkably high incidence of near-fainting during the tilt-up test after intravascular instrumentation raises serious doubts about the utility of this procedure in evaluating syncope of unknown origin in young subjects.

Adolescent↗

Comparison of intrabrachial and finger blood pressure in healthy elderly volunteers.

This study was performed to compare continuous Finapres (FIN) and intrabrachial (IAP) blood pressure in healthy elderly volunteers. Fifteen elderly subjects (age 71 to 83) without cardiovascular disease and an intraarterial mean (range) systolic and diastolic blood pressure of 162 (122 to 195) and 73 (62 to 88) mm Hg, respectively, participated in the study. A 10-min head-up tilt, 10 min active standing, a 15-sec Valsalva, and a 5-min mental arithmetic were performed in random order. Beat-to-beat values of systolic, diastolic, and mean arterial pressure were analyzed. At rest, FIN underestimated IAP by 16.8 +/- 2.6 (SE), 10.8 +/- 1.5, and 17.5 +/- 1.6 mm Hg for systolic, diastolic, and mean arterial blood pressure, respectively (P < .05). During head-up tilt, FIN overestimated the intraarterial systolic blood pressure response by 7.2 +/- 1.6 (SE) mm Hg (P < .05). Group-averaged changes in diastolic and mean arterial IAP were followed closely by FIN. During standing, Finapres closely followed intraarterial diastolic and mean arterial pressure but the increase in systolic blood pressure was higher at the finger as compared to intrabrachial recordings, resembling the results of head-up tilt. During the Valsalva maneuver, maximal responses in systolic, diastolic, and mean arterial pressure were underestimated by FIN by 12.1 +/- 3.3 (SE), 6.8 +/- 2.7, and 7.1 +/- 1.7 mm Hg, respectively (P < .05 for all parameters). During mental arithmetic, FIN underestimated the intraarterial systolic blood pressure response by 6.1 +/- 2.7 (SE) mm Hg (P < .05), while diastolic and mean arterial pressure responses were followed correctly by FIN. It is concluded that apart from systolic blood pressure, FIN closely follows intraarterial blood pressure responses for the orthostatic maneuvers and mental arithmetic. During Valsalva, the rapid changes in blood pressure were followed in direction but not in magnitude.

Aged↗

Effects of ketanserin on heart rate and blood pressure variability: implications for the effect on the baroreflex mechanisms.

Ketanserin is an antihypertensive drug with affinity to both serotonin S2- and alpha 1-adrenoceptors. The specific effects of ketanserin on the baroreflex are not fully understood. We, therefore, studied baroreflex regulation based on blood pressure (BP) and heart rate (HR) responses to several maneuvers before and after the administration of 2 x 5 mg of ketanserin i.v. both in supine and in standing posture. Seven young healthy volunteers were investigated. We measured spontaneous variability in HR and BP (Finapres), and performed deep inspiration, Valsalva, and lying-to-standing tests. We also used a modified Valsalva maneuver that consist of Deep Inspiration Breath-holding with closed glottis and EXpiration: DIBEX maneuver. From the BP recordings, peripheral resistance (TPR) and stroke volume (SV) were estimated by the Modelflow method. Thirty minutes after the administration of ketanserin, there was no significant change in mean HR, BP, spectral power of HR and BP variability, baroreflex sensitivity, or Valsalva ratio. Thus ketanserin did not affect the cardiac baroreflex mechanism. However, in standing position, SV increased and TPR decreased under the influence of ketanserin, and BP overshoot after the Valsalva and DIBEX maneuver was significantly decreased as well. There was also no reflex recovery of BP during the DIBEX maneuver in three volunteers, who felt faint. These observations indicate that there is a lack of vasoconstriction. We conclude that ketanserin is not a vasodilator but seems to inhibit vasoconstriction.

Adult↗

Circadian profile of systemic hemodynamics.

We determined the continuous 24-hour profile of mean arterial pressure, heart rate, stroke volume, cardiac output, and total peripheral resistance in eight healthy ambulatory volunteers. Beat-to-beat intra-arterial blood pressure was recorded with the Oxford system; subjects were ambulant during daytime and slept at night. Beat-to-beat stroke volume was determined by the pulse contour method from the arterial pulse wave. During the nighttime, compared with the daytime average, there was a decrease in blood pressure (9 mm Hg), heart rate (18 beats per minute), and cardiac output (29%); stroke volume showed a small decrease (7%), and total peripheral resistance increased unexpectedly by 22%. When subjects arose in the morning a steep increase in cardiac output and decrease in total peripheral resistance were found. Comparable changes were seen during a period of supine resting in the afternoon, whereas physical exercise caused opposite changes in hemodynamics. This pattern was observed in all subjects. We conclude that the circadian pattern of cardiac output and total peripheral resistance originates from the day-night pattern in physical activity: during the nighttime, blood flow to the skeletal muscles is decreased through local autoregulation, which increases total peripheral resistance and decreases cardiac output compared with the daytime.

Adolescent↗

Effect of regional and systemic changes in vasomotor tone on finger pressure amplification.

Pulse wave amplification, which leads to increased peripheral systolic pressure, is observed during vasoconstriction after head-up tilt and during exercise. This may influence finger pressure measurements with the Finapres. To distinguish between changes in regional vascular tone and changes in systemic hemodynamics as a cause of pulse wave amplification, we measured finger pressure, intra-arterial brachial artery pressure, heart rate, and left ventricular ejection time during high-dose intravenous and low-dose intra-arterial infusions of phenylephrine and sodium nitroprusside in eight subjects. Forearm blood flow was measured by means of venous occlusion plethysmography. Intravenous phenylephrine at the highest dose caused an increase in mean brachial artery pressure of 24 +/- 3 mm Hg, a decrease in heart rate of 10 +/- 11 beats per minute, and an increase in ejection time of 23 +/- 9 milliseconds (all P < .01), whereas pulse wave amplification was reduced. Finapres underestimated the rise in systolic brachial artery pressure of 41 +/- 9 mm Hg by 11 +/- 12 mm Hg (P < .01). Forearm blood flow did not change. Intravenous nitroprusside caused a decrease in mean brachial artery pressure of 23 +/- 9 mm Hg, an increase in heart rate of 18 +/- 11 beats per minute, and a decrease in ejection time of 36 +/- 31 milliseconds (all P < .01), whereas pulse wave amplification increased. Finapres underestimated the fall in systolic brachial artery pressure of 30 +/- 13 mm Hg by 9 +/- 10 mm Hg (P < .05). Forearm blood flow did not change. During regional infusion of phenylephrine and nitroprusside forearm flow halved and doubled, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Computation of aortic flow from pressure in humans using a nonlinear, three-element model.

We computed aortic flow pulsations from arterial pressure by simulating a nonlinear, time-varying three-element model of aortic input impedance. The model elements represent aortic characteristic impedance, arterial compliance, and systemic vascular resistance. Parameter values for the first two elements were computed from a published, age-dependent, aortic pressure-area relationship (G. J. Langewouters et al. J. Biomech. 17:425-435, 1984). Peripheral resistance was predicted from mean pressure and model mean flow. Model flow pulsations from aortic pressure showed the visual aspects of an aortic flow curve. For evaluation we compared model mean flow from radial arterial pressure with thermodilution cardiac output estimations, 76 times, in eight open heart surgical patients. The pooled mean difference was +7%, the SD 22%. After using one comparison per patient to calibrate the model, however, we followed quantitative changes in cardiac output that occurred either during changes in the state of the patient or subsequent to vasoactive drugs. The mean deviation from thermodilution cardiac output was +2%, the SD 8%. Given these small errors the method could monitor cardiac output continuously.

Aged↗

Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.

We tested Portapres, an innovative portable, battery-operated device for the continuous, noninvasive, 24-hour ambulatory measurement of blood pressure in the finger. Portapres is based on Finapres, a stationary device for the measurement of finger arterial pressure. Systems were added to record signals on tape, to alternate measurements between fingers automatically each 30 minutes, and to correct for the hydrostatic height of the hand. We compared the pressure as measured by Portapres with contralateral intrabrachial pressure measured with an Oxford device. Results were obtained in eight volunteers and 16 hypertensive patients. Time lost due to artifact was about 10% for each device. In two patients a full 24-hour Oxford profile was not obtained. In the remaining 22 subjects finger systolic, diastolic, and mean pressures differed +1 (SD 9), -8 (6), and -10 (6) mm Hg, respectively, from intrabrachial pressure. These diastolic and mean pressure underestimations are similar to what was found earlier for Finapres, are typical for the technique, and are systematic. Avoiding brisk hand movements resulted in fewer waveform artifacts. The hand had to be kept covered to continue recording at low outside temperatures. Sleep was not disturbed by Portapres, and arterial pressure showed a marked fall during siesta and nighttime. There were no major limitations in behavior, and no discomfort that originated from continuous monitoring was reported. Measurements continued normally during physical exercise. Portapres provides for the first time continuous 24-hour, noninvasive ambulatory blood pressure waveform monitoring and offers real and obvious advantages over current noninvasive and invasive devices.

Adult↗

The reliability of noninvasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease.

In conditions of compromised peripheral circulation, the measurement of noninvasive continuous finger blood pressure with the Finapres device may show reduced accuracy. We therefore compared Finapres blood pressure (FINAP) with intrabrachial blood pressure (IAP) responses to the Valsalva maneuver and arising in 12 patients in whom the peripheral circulation was expected to be compromised due to the combination of therapy-resistant hypertension and vascular disease. During a 30 sec control period the FINAP--IAP differences were -15.7 +/- 18.8 mm Hg (mean +/- SD) for systolic, -20.1 +/- 15.7 mm Hg for mean, and -13.5 +/- 15.7 mm Hg for diastolic pressure. During the Valsalva maneuver and prolonged standing Finapres reproduced the essential characteristics of the changes in IAP in all patients. However, in individual patients, the magnitude of the intraarterial blood pressure response was sometimes over- or underestimated by Finapres. Nevertheless, the group averaged blood pressure, in particular mean and diastolic pressure, response to cardiovascular stimuli, was well reproduced by Finapres. In conclusion, as expected physiologically, individual Finapres measurements in patients with vascular disease do not always equal the intrabrachial pressure and should thus be evaluated with care. However, the Finapres device can be used with sufficient confidence to study the group averaged responses to cardiovascular stimuli in these patients.

Aged↗

Influence of short-term blood pressure variability on blood pressure determinations.

To evaluate the effect of blood pressure variability on Riva Rocci Korotkoff blood pressure determinations, we studied the intra-arterial pressure during Riva Rocci Korotkoff determinations in 25 patients. In 50 measurements with a cuff deflation rate of 2.5 mm Hg/sec, the systolic intra-arterial pressure at Korotkoff phase 1 was 2.1 (95% confidence interval 1.2-3.0) mm Hg higher than the average systolic intra-arterial pressure in the 20 seconds surrounding this moment (p less than 0.01). This elevation was shown to increase with increasing blood pressure variability, as expressed by the standard deviation of the systolic blood pressure. The elevation caused by the proposed mechanism was amplified when a slow cuff deflation rate of 1.5 mm Hg/sec was used. No significant difference was noted in the diastolic intra-arterial pressure at Korotkoff phase 5, when a normal deflation rate of 2.5 mm Hg/sec was used. A slow cuff deflation rate caused a small elevation in diastolic pressure at the moment of Korotkoff phase 5. We conclude that even normally occurring blood pressure variability might lead to a consistent elevation of systolic Riva Rocci Korotkoff blood pressure measurements. This effect is reinforced by an increasing blood pressure variability and by a slower cuff deflation rate.

Aged↗

Pseudohypertension and the measurement of blood pressure.

Riva-Rocci Korotkoff (RRK) blood pressure measurements may overestimate the intra-arterial pressure (IAP) in individual patients. To study pseudohypertension, defined as an overestimation larger than 10 mm Hg, we compared RRK and IAP measurements in 76 patients. These patients were considered to be at risk for pseudohypertension because of high age, hypertension, or vascular disease. RRK measurements underestimated simultaneously measured systolic IAP values by 6.0 +/- 6.5 (mean +/- SD) mm Hg, whereas simultaneous diastolic RRK readings overestimated the IAP by 1.9 +/- 5.6 mm Hg. Diastolic overestimation increased slightly with age. Vascular rigidity, as measured by counterpressure plethysmography, did not correlate with these errors. Systolic and diastolic pseudohypertension was observed in two and five patients, respectively. Pseudohypertension was only present in the group in which IAP was measured in the aorta. However, the number of patients with systolic and diastolic pseudohypertension could be increased to three and seven by using the average intra-arterial systolic and diastolic pressure during an RRK measurement or to six and 11 by using the IAP during a control period just before an RRK measurement rather than the IAP at the moment of appearance or disappearance of the Korotkoff sounds. The widely diverging prevalence of pseudohypertension described in the literature might be explained because of such different comparison techniques.

Adult↗

Effects of graded vasoconstriction upon the measurement of finger arterial pressure.

OBJECTIVE: To assess the effects of incremental phenylephrine infusion rates and subsequent graded vasoconstriction upon the performance of the Ohmeda Finapres. DESIGN: Blood pressure in eight hypertensive patients in the finger and the brachial artery was recorded simultaneously. Systolic blood pressure (SBP), diastolic blood pressure (DPB) and mean arterial pressure (MAP) were compared as well as additional waveform characteristics like the pressure at moment of the dicrotic notch and calculation of the pulsatile-systolic areas. RESULTS: Before phenylephrine infusion SBP and DBP were higher in the finger. At maximal infusion (1.6 micrograms/kg/min) the increase in brachial SBP was significantly underestimated by Finapres. Thus, the computed sensitivities of baroreflex control for SBP differed significantly between the two measurements. Under control conditions, the shape of the finger waveform differed from the brachial-artery waveform in terms of: (1) a more peaked appearance; (2) a dicrotic notch (Pnotch) which is located at a lower percentage of pulse pressure; and (3) a larger pulsatile-systolic area. At maximal infusion rates finger Pnotch increased whilst intrabrachial Pnotch did not. In contrast, the brachial and finger pulsatile-systolic areas changed fully in parallel. CONCLUSIONS: Phenylephrine infusion caused a significant, and clinically important, underestimation of the increase in brachial SBP when assessed by Finapres, whereas MAP and DBP and pulsatile-systolic area track intra-arterial pressure reliably.

Arteries↗

Circulatory responses to stand up: discrimination between the effects of respiration, orthostasis and exercise.

The initial circulatory responses to an active change in posture (stand up from supine) were compared with the responses induced by a passive change in posture (head-up tilt) and a burst of muscular exercise on a bicycle ergometer (upright cycling) in order to differentiate between exercise- and orthostasis-induced effects. In eight subjects heart rate responses and in four subjects intra-arterial pressure transients were measured. In addition the effects of respiration on heart rate responses to the three manoeuvres were assessed. Both stand up and cycling induced almost superimposable and pronounced heart rate responses lasting for about 30 s. This contrasts with the more gradual increases following head-up tilt. Changing the respiratory phase during the performance of the manoeuvres exerted its effect on heart rate responses in the first 5 s only. Like stand up, cycling induced a transient blood pressure fall lasting for 30 s on average. As both manoeuvres were performed during inspiration the transients observed are not caused by involuntary Valsalva straining. In conclusion, the maximum and duration of the heart rate responses induced by stand up, cycling and head-up tilt are not influenced by respiratory activity. The initial fall in blood pressure following stand up is probably the result of the muscular effort of the manoeuvre and not due to the effects of orthostasis or Valsalva straining.

Adult↗

Initial blood pressure fall on stand up and exercise explained by changes in total peripheral resistance.

To elucidate the underlying mechanisms of the initial fall in blood pressure on standing upright from the supine position, we measured the beat-to-beat changes in intra-arterial pressure in eight healthy male subjects in response to standing. Changes in stroke volume, cardiac output, and total peripheral resistance were computed from the pressure waveform using a pulse contour method. To determine possible mechanisms for the changes observed on standing, similar measures were made on passive tilting and a brief (3-s) bout of cycle exercise. Standing elicited a transient 25% (23-mmHg) fall in mean blood pressure as a result of a 36% fall in total peripheral resistance. Head-up tilt elicited a gradual change in haemodynamic parameters, which reached plateau levels in 20-30 s. Cycling elicited a transient 17% (18-mmHg) fall in blood pressure and a 41% fall in total peripheral resistance. In addition, we measured right atrial and esophageal pressures in two subjects on standing and cycling and found a 10- to 15-mmHg rise in right atrial pressure without a corresponding change in esophageal pressure. This points to the cardiopulmonary reflex as the primary effector of peripheral vasodilation, but we cannot exclude the possibility that 1) local metabolic vasodilation and 2) central command-mediated cholinergic vasodilation contributed to the fall in vascular resistance.

Adult↗

Singing-induced hypotension: a complication of a high spinal cord lesion.

Cardiovascular autonomic control was studied in a patient with an incomplete high spinal cord lesion who presented with the symptoms of severe dizziness during debating and singing but not during orthostasis. The marked falls in blood pressure upon singing and orthostasis (45 degrees passive head-up tilt) were comparable in magnitude but different in time course. The fall in blood pressure upon graded Valsalva manoeuvres, however, was comparable to singing in magnitude and time course; similarly, 20 and 30 mmHg strain evoked complaints of dizziness. These differential circulatory responses upon orthostasis versus singing and Valsalva in tetraplegic patients have not been described before. We suggest that rapidly developing hypotension such as that induced by a moderate Valsalva strain represents the instantaneous mechanical effects of a raised intrathoracic pressure with lack of abdominal compression on the cardiovascular system when baroreflex vasomotor modulation is disrupted.

Adult↗

Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure.

STUDY OBJECTIVE: The aim of the study was to evaluate whether invasive blood pressure responses to orthostatic stress can be replaced by non-invasive continuous finger blood pressure responses. DESIGN - Intrabrachial and Finapres blood pressures were simultaneously measured during passive head up tilt and during active standing from the supine or sitting position in healthy volunteers. SUBJECTS: Subjects (n = 11) were healthy males aged 22-40 years, mean age 30 years. MEASUREMENTS AND MAIN RESULTS: Beat to beat values of systolic, diastolic, and mean arterial pressures were calculated for both methods of measurement and the differences compared during a 30 s control period before, and during the first 120 s after, the change of posture. In the control period the difference between finger pressure and intra-arterial pressure was +2 (SD11) mm Hg for systolic, -4(8) mm Hg for mean, and -3(7) mm Hg for diastolic pressure. Compared to these control differences, the average finger minus intra-arterial pressure differences for mean and diastolic pressures during the three orthostatic manoeuvres were always within the range -6 to +6 mm Hg. The average systolic deviations were larger, ranging from -10 to +11 mm Hg. Despite these differences the characteristic changes in intra-arterial pressure during the initial phase (first 30 s after change of posture), as well as during the early steady state phase (1-2 min after the change of posture) were well reflected by finger pressure measurements in all subjects. CONCLUSIONS: For the assessment of the continuous blood pressure responses to orthostatic stress similar information can be obtained with non-invasive Finapres blood pressure recordings as with invasive recordings.

Adult↗