Reproducibility of electrophysiological testing during antiarrhythmic therapy for ventricular arrhythmias unrelated to coronary artery disease.

Although electrophysiological studies are commonly used in the management of patients with ventricular tachycardia (VT), the reproducibility of these studies during therapy has not been established in patients in whom VT is associated with conditions other than coronary artery disease. Therefore, we performed confirmation studies during drug therapy in 60 patients (mean age 48 +/- 18 years; 41 male) with sustained ventricular arrhythmias induced during initial study to assess the reproducibility of drug effect. The stimulation protocol used included the serial introduction of up to three premature ventricular stimuli during sinus rhythm and with ventricular pacing at two pacing rates. Rapid ventricular pacing techniques were also used. Antiarrhythmic drug efficacy was confirmed in 78% of patients. Sustained VT was induced at repeat electrophysiological study in 18% of patients during antiarrhythmic therapy that had been felt to be effective on the basis of a single drug study. We conclude that electrophysiological study results during antiarrhythmic therapy exhibit significant day-to-day variability. Sustained VT can be induced during antiarrhythmic therapy previously determined to be effective by electrophysiological techniques in many patients.

Anti-Arrhythmia Agents↗

Comparison and frequency of ventricular arrhythmias after defibrillator implantation by thoracotomy versus nonthoracotomy approaches.

Postoperative exacerbation of ventricular arrhythmias has been reported in some patients treated with thoracotomy implantable cardioverter-defibrillators (ICDs). This phenomenon, which may be related to epicardial patch electrodes, may be less frequent after nonthoracotomy ICD implantation. In this nonrandomized study, postoperative arrhythmias in thoracotomy approaches (n = 52) were compared with those in nonthoracotomy approaches (n = 59). Preoperatively, all patients were clinically stable receiving an antiarrhythmic regimen chosen by serial drug testing. Nine of 52 patients in the thoracotomy group developed sustained ventricular tachycardia postoperatively while receiving the same antiarrhythmic regimen chosen preoperatively, and 1 patient eventually died. Two additional patients developed frequent and prolonged episodes of nonsustained ventricular tachycardia requiring changes in the antiarrhythmic regimen. In the nonthoracotomy group, only 3 of 59 patients developed sustained ventricular tachycardia and 1 developed frequent nonsustained ventricular tachycardia. Thus, only 4 of 59 patients in the nonthoracotomy group developed clinically significant ventricular arrhythmia during the postoperative period compared with 11 of 52 patients in the thoracotomy group (p < 0.05). Surgical mortality was 6% in the thoracotomy group, and 0% in the nonthoracotomy group. In the remaining clinically stable patients, a marked (sevenfold) increase in asymptomatic ventricular arrhythmias was noted in 15 of 39 patients in the thoracotomy group, and in 3 of 55 patients in the nonthoracotomy group (p < 0.05). Thus, postoperative exacerbation of ventricular arrhythmia, sometimes noted with thoracotomy approaches, is very rare with nonthoracotomy approaches.

Aged↗

Comparison of defibrillator therapy and other therapeutic modalities for sustained ventricular tachycardia or ventricular fibrillation associated with coronary artery disease.

Outcomes of 282 patients referred to the arrhythmia service at Montefiore Medical Center for sustained ventricular tachycardia (n = 214) or ventricular fibrillation (n = 68) associated with coronary artery disease were analyzed retrospectively. All patients underwent serial drug trials by electrophysiologic testing and Holter monitoring. Sixty-eight patients who did not respond to drug therapy were treated with implantable cardioverter-defibrillators (ICD group), and 214 patients were treated with other methods guided by electrophysiologic testing and Holter monitoring (non-ICD group). The non-ICD group included 49 patients who responded to drug therapy as judged by electrophysiologic testing, as well as patients who did not respond and were not treated with defibrillator therapy for various reasons. Ten patients died in the hospital (2 patients in the ICD group, 8 in the non-ICD group). Actuarial survival rates free of total cardiac death at 1, 2, and 3 years were, respectively, 94%, 87%, and 85% in the ICD group, and 82%, 78%, and 73% in the non-ICD group (p = NS). Survival rates free of total death at 1, 2, and 3 years were 90%, 82%, and 76% in the ICD group, and 82%, 76%, and 70% in the non-ICD group, respectively (p = NS). Survival rates free of total cardiac and total deaths of 49 patients treated with an effective regimen determined by electrophysiologic testing were not significantly different from those of the ICD group. This retrospective study suggests that outcomes of patients treated with ICDs may not be dramatically different from those of patients treated with other methods guided primarily by electrophysiologic testing.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

ICD implantation via thoracoscopy, "mailslot" thoracotomy, and subxiphoid incision.

An improved method of thoracoscopic implantable cardioverter defibrillators implantation is described. "Mailslot" thoracotomy is more expeditious than thoracoscopic implantation via multiple ports. If required for adequate defibrillation thresholds, subxiphoid, subdiaphragmatic implantation of a defibrillator patch may be performed.

Aged↗

Programmed ventricular stimulation using tandem versus simple sequential protocols.

UNLABELLED: The objective was to determine whether two commonly used ventricular stimulation protocols, one more complex than the other, produced concordant results. If such were the case, the simpler protocol would streamline activities in clinical electrophysiology laboratories. BACKGROUND: Two programmed ventricular stimulation protocols were compared. (1) With the tandem method, the first extrastimulus (S2) is moved stepwise to the effective refractory period and then moved out 50 msec; the second extrastimulus (S3) is then decremented until it fails to capture; S2 and S3 are then decremented in a semialternating (tandem) fashion so that both continue to capture. When S2 reaches the refractory period + 10 msec and S3 fails to capture, S3 is then moved out 50 msec, and S4 is decremented as described for S3. (2) With the simple sequential method, the first extrastimulus (S2) is decremented stepwise to the refractory period, and then moved out 10 msec to assure capture; S3 is then similarly decremented to the refractory period and then moved out 10 msec; and S4 is then similarly decremented. METHODS: This was a prospective, randomized, crossover, consecutive series study. Both protocols were tested in each patient on the same day in randomized order. RESULTS: There were 84 matched studies. Fifty-six patients provided data from baseline electrophysiological studies, and 28 of these provided additional data during drug trials. There was a 93% concordance between the two methods, including the primary outcomes of inducibility of clinical arrhythmias, inducibility of nonclinical arrhythmias, and noninducibility (P < 0.001). Discordances were few and evenly distributed between the two protocols (P = NS). Results were similar for baseline studies and drug trials. The simple sequential method required less time to perform (P < or = 0.01). CONCLUSIONS: Tandem and simple sequential protocols provide concordant results. No advantage could be demonstrated for the more complex tandem method.

Adolescent↗

Influence of left ventricular function on survival and mode of death after implantable defibrillator therapy (Cleveland Clinic Foundation and Montefiore Medical Center experience).

To determine the influence of left ventricular (LV) function on survival and mode of death in patients with an implantable cardioverter-defibrillator (ICD), sudden death, surgical mortality, total arrhythmia-related death, total cardiac death and total death were retrospectively evaluated in 377 consecutive patients. The outcomes were also compared between patients with an LV ejection fraction > or = 30% (214 patients, group 1) and < 30% (148 patients, group 2). Surgical mortality was 3.9% (1.8% in group 1, 7% in group 2). During the follow-up of 25 +/- 20 months, actuarial survival rates of all patients at 3 years were 96% for sudden deaths, 81% for total cardiac deaths and 74% for total mortality. When the 2 groups were compared, survival rates of groups 1 and 2 at 3 years, respectively, were 99 and 90% for sudden death (p < 0.05), 97 and 84% for sudden death and surgical mortality (p < 0.01), 94 and 80% for the total arrhythmia-related death (p < 0.001), 88 and 68% for total cardiac death (p < 0.0001), and 81 and 62% for total mortality (p < 0.002). In group 2, 73% of total cardiac deaths within 1 year were causally related to the arrhythmia. Thus, in patients with an ICD, sudden death rates were very low. However, total cardiac death and total death rates were relatively higher. The outcomes of patients with an ICD were strongly influenced by the degree of LV dysfunction.(ABSTRACT TRUNCATED AT 250 WORDS)

Actuarial Analysis↗

Rapid suppression of spontaneous ventricular arrhythmias during oral amiodarone loading.

OBJECTIVE: To determine the time course of effects of amiodarone during an oral loading period. DESIGN: A prospective, nonrandomized study. SETTING: Arrhythmia referral center at a university hospital. PATIENTS: Fifty patients with refractory sustained ventricular tachycardia (n = 44) or ventricular fibrillation (n = 6) and frequent (greater than or equal to 30/h) ventricular premature complexes. INTERVENTION: Oral amiodarone, 1200 mg/d for 14 days and 400 mg/d thereafter. MEASUREMENTS: Ambulatory electrocardiographic monitorings, 12-lead electrocardiograms, and amiodarone blood levels on days 3, 5, 7, 9, 11, 13, and 28. RESULTS: Dramatic reductions of ventricular arrhythmias were noted during the first 72 hours of the therapy. Average ventricular premature complexes/h, couplets/h, and nonsustained ventricular tachycardias/24 h were 524 +/- 1224/h, 16 +/- 61/h, and 167 +/- 611/24 h, respectively, at baseline, and reduced to 140 +/- 243/h, 11 +/- 50/h, and 33 +/- 117/24 h, respectively, on day 3 (P less than 0.05 for all). Subsequent reductions of ventricular arrhythmias from day 3 to day 13 were more gradual but were still significant (P less than 0.05). A significant reduction of ventricular arrhythmias (greater than or equal to 70% reduction of ventricular premature complexes and greater than or equal to 90% reduction of nonsustained ventricular tachycardias) was noted in 50% of patients on day 3, in 65% on day 7, and in 83% on day 13. Prolongation of the QT interval exhibited a similar time course. There were no further differences in reduction of ventricular premature complexes or QT intervals between day 13 and day 28. CONCLUSIONS: Oral amiodarone given in loading doses produces rapid and dramatic reductions in spontaneous ventricular arrhythmias within 72 hours. Subsequent reductions of spontaneous arrhythmia were gradual and less dramatic.

Administration, Oral↗

Reproducibility of electrophysiologic testing during antiarrhythmic therapy for ventricular arrhythmias secondary to coronary artery disease.

Although electrophysiologic studies are often used to assess antiarrhythmic drug efficacy in patients with ventricular tachycardia (VT), the reproducibility of these studies during therapy has not been definitively established. Confirmation studies were performed during drug therapy in 64 patients (51 men, mean age 63 years) with sustained ventricular arrhythmias induced during initial study to assess the reproducibility of drug effect. All patients had coronary artery disease. The stimulation protocol used included the serial introduction of up to 3 premature ventricular stimuli during sinus rhythm and with ventricular pacing at 2 pacing rates. Rapid ventricular pacing techniques were also used. Antiarrhythmic drug efficacy was confirmed in 77% of patients. Sustained VT was induced at repeat electrophysiologic study in 19% of patients during antiarrhythmic therapy that was previously thought to be effective. In summary, electrophysiologic study results during antiarrhythmic therapy exhibit significant day-to-day variability. Sustained VT can be induced during antiarrhythmic therapy that was previously defined as effective by programmed stimulation in a substantial number of patients.

Adult↗

Implementation of a new DDDR algorithm for tachycardia prevention and treatment utilizing an implantable RAM-based software-controlled pacemaker.

Reentry within the atrioventricular node or over accessory pathways are common causes of symptomatic tachycardia. These arrhythmias are frequently initiated by a spontaneous atrial or ventricular premature beat. Appropriately timed atrial or ventricular extrastimuli can, in some patients, render one limb of the reentrant circuit refractory and prevent induction of tachycardia. Currently available implantable devices are not suitable for this application. The authors have implemented a new implantable pacing algorithm capable of extremely short atrial and ventricular refractory periods, rapid triggered ventricular pacing rates, protection against encroachment on the ventricular vulnerable period, protection against tachycardia induction by ventricular premature beats, automated antitachycardia pacing in either atrium and ventricle, as well as an extensive event storage capability. This application has been made possible by a new, RAM-based microprocessor controlled dual chamber pacemaker (Medtronic Prometheus Model 6100). Its use in intraatrial tachycardia with atrioventricular block as well as Wolff-Parkinson-White syndrome is demonstrated. This device is capable of prevention of tachycardia induction in some patients. Where prevention is not feasible or fails, it is backed up by automated or manually activated antitachycardia pacing. The great flexibility of a completely reprogrammable software based pacemaker has enabled the implementation of a very complex experimental pacemaker that will permit evaluation in the implanted setting of this new pacing strategy.

Algorithms↗

Programmed electrical stimulation protocols: variations on a theme.

A series of prospective protocols were designed to determine the yield ratio (true positives vs. false positives = nonclinical) in various patient groups using a variety of programmed electrical stimulation (PES) variables. First, a PES protocol was used in 772 patients. Single, double, and triple extrastimuli were delivered in sequence (leaving each successive extrastimulus just beyond its refractory period before moving to the next extrastimulus) during sinus rhythm and two ventricular paced rates at the RV apex, before moving to the outflow tract and repeating the sequence and then moving on to isoproterenol infusion with the PES sequence repeated at the apex. This protocol met NASPE standards for induction of VT in patients with coronary artery disease and a history of VT, while failing to induce monomorphic VT in any control patient. The best yield ratios combined with the greatest likelihood of inducing clinical tachycardia were achieved with sinus rhythm and three extrastimuli, and pacing at the lower rate and three extrastimuli. Pacing at the faster rate and triple extrastimuli was highly inductive of clinical arrhythmias, but had a low yield ratio due to induction of more nonclinical arrhythmias than other steps. The next protocol was performed in 61 patients with inducible ventricular tachycardia. In each case, the protocol described above was completed at the RV apex, even if tachycardia was also induced at an earlier point in the protocol. This allowed for more accurate yield ratios to be established for each step in the protocol, since each patient was exposed to each of these steps.(ABSTRACT TRUNCATED AT 250 WORDS)

Arrhythmias, Cardiac↗

Programmed electrical stimulation of the ventricle: an efficient, sensitive, and specific protocol.

A relatively simple and efficient ventricular programmed electrical stimulation (PES) protocol was developed, capable of achieving high degrees of sensitivity and specificity. In a series of 481 subjects, 1, 2, and 3 extrastimuli (ES) were used successively during sinus rhythm and ventricular pacing at two drive cycle lengths, at one or more ventricular sites, together with rapid ventricular pacing, and other maneuvers such as isoproterenol infusion. Three ES were used immediately after two ES at each drive rate, rather than returning after completion of the protocol with two ES. Using the protocol, appropriate arrhythmias could be induced in 88% of all patients with ventricular fibrillation, 84% of all patients with sustained ventricular tachycardia (91% with underlying coronary disease), and 58% of patients with severe nonsustained ventricular tachycardia. There were significant differences in inducibility between patients whose ventricular arrhythmias were due to coronary artery disease and other causes. In contrast, sustained ventricular arrhythmias (all ventricular fibrillation) could be induced in only 5% of a control group of control patients, for a specificity of 95%. The protocol described is simpler and more efficient than those that use exhaustive testing of two ES before going to three ES. Three ES during sinus rhythm proved to be the most productive step, with a higher yield ratio (true: false-positives) than two ES or three ES during pacing, especially at faster rates. Greater efficiency is also achieved by leaving the timing of an extrastimulus just beyond its effective refractory period when an additional extrastimulus is to be added, compared to protocols in which the extrastimulus is moved later in the cycle and then decremented in tandem with the additional extrastimulus. Coupling intervals less than 200 msec produced some false-positives, but fewer overall than intervals greater than or equal to 200 msec, and with yield ratios comparable to other protocol steps. The protocol described meets NASPE standards for ventricular programmed stimulation protocols, and with its demonstrated specificity and relative simplicity and efficiency may be useful as a model for groups not yet committed to an alternative protocol.

Cardiac Pacing, Artificial↗

Stimulation hierarchy: optimal sequence for double and triple extrastimuli during electrophysiological studies.

To determine the optimal ventricular stimulation sequence, an 11-step programmed electrical stimulation (PES) protocol was completed, even if a ventricular arrhythmia (VA) was induced with earlier steps. The protocol consisted of one, two, and three extrastimuli during sinus rhythm (SR), and at two drive pacing rates (VP1 and VP2) plus rapid burst and ramp pacing. By analyzing the 79 completed protocols that induced the clinical arrhythmia, the following were determined: (1) the frequency of induced clinical and nonclinical VA with each stimulation step; (2) the yield ratio (YR) of each step, defined as the probability of inducing clinical versus nonclinical arrhythmia; (3) the cumulative yield of induced clinical and nonclinical arrhythmia with two widely used stimulation sequences, i.e., triple extrastimuli delivered early in the stimulation protocol (MMC sequence) and triple extrastimuli delayed until after double extrastimuli failed to induce the clinical arrhythmia (B sequence); (4) the relative efficiency of these sequences were determined. The percentage of induced clinical and nonclinical arrhythmia with SR + 3 extrastimuli, VP1 + 2 extrastimuli, and VP2 + 2 extrastimuli were (53%, 5%), (36%, 5%), and (41%, 9%), respectively. The cumulative yield of induced clinical VA with the MMC-type sequence reached 55% by the third step of the protocol, whereas 50% was attained only at the eighth step of the B-type sequence. The cumulative percentage of induced nonclinical VA with either sequence was similar during the early steps of the protocol. The MMC sequence was more efficient, requiring overall 36% of potential steps for clinical arrhythmia induction, compared with 48% for the B sequence (P less than 0.001). For questionable arrhythmia states, e.g., syncope of unknown origin and nonsustained VT, a modified sequence is proposed that may further reduce the induction of uninterpretable arrhythmias.

Anti-Arrhythmia Agents↗

Influence of left ventricular function on outcome of patients treated with implantable defibrillators.

BACKGROUND: The outcomes of patients treated with implantable defibrillators were compared between patients with left ventricular ejection fraction greater than or equal to 30% and less than 30%. METHODS AND RESULTS: Of 68 consecutive patients treated with implantable defibrillators, 40 patients (group 1) had left ventricular ejection fraction greater than or equal to 30%, and 28 patients (group 2) had left ventricular ejection fraction less than 30%. Sudden death, surgical mortality, nonsudden arrhythmia-related death (death within 24 hours after an arrhythmic event despite initial termination of the arrhythmia by the implantable defibrillator), total arrhythmia-related death (including sudden death, surgical death, and nonsudden arrhythmia-related death), and total cardiac death were compared between the two groups. Surgical mortality was 4.4% (0% in group 1, 11% in group 2). During the follow-up of 31 +/- 27 months, actuarial survival rates free of events were 97%, 97%, and 97% in group 1 and 96%, 91%, and 82% in group 2 at 12, 24, and 36 months, respectively, for sudden death (p = NS); 97%, 97%, and 97% in group 1 and 85%, 81%, and 72% in group 2 at 12, 24, and 36 months, respectively, for sudden death and surgical mortality (p less than 0.05); 97%, 97%, and 97% in group 1 and 82%, 78%, and 70% in group 2 at 12, 24, and 36 months, respectively, for total arrhythmia-related death (p less than 0.05); and 95%, 95%, and 95% in group 1 and 82%, 69%, and 57% in group 2 at 12, 24, and 36 months, respectively, for total cardiac death (p less than 0.05). Four (57%) of seven nonsudden cardiac deaths during the initial 36-month follow-up period were causally related to arrhythmia (three surgical deaths and one arrhythmia-related nonsudden death). CONCLUSIONS: The outcome of patients treated with implantable defibrillators is strongly influenced by the degree of left ventricular dysfunction. In group 1 patients, surgical mortality, sudden death, and total cardiac death are rare. In group 2, sudden death rate may not be markedly different from that of group 1 patients. However, the risk of therapy (surgical mortality) is high. Many nonsudden cardiac deaths are causally related to arrhythmia (surgical mortality or nonsudden arrhythmia-related death). Therefore, the survival rate free of total arrhythmia-related death is significantly lower in group 2 (70% versus 97% in group 1 at 3 years). Further studies are needed to determine the roles of defibrillator therapy and other therapies in various clinical settings.

Actuarial Analysis↗

Exacerbation of ventricular arrhythmias during the postoperative period after implantation of an automatic defibrillator.

The postoperative course of 68 consecutive patients treated with an implantable defibrillator during the period from 1982 through 1990 was studied. In 46 patients (group 1), no concomitant surgery was performed during the implantation. In 22 patients (group 2), concomitant surgery (coronary artery bypass [n = 12], valve replacement [n = 3] or arrhythmia surgery [n = 7]) was performed. All patients in group 1 were clinically stable before surgery, receiving an antiarrhythmic regimen chosen by serial drug testings. The same regimen was continued postoperatively. Eight of the 46 patients in group 1 whose condition had been stable in the hospital for 19 +/- 25 days preoperatively developed multiple episodes of sustained ventricular tachycardia 4 +/- 9 days after implantation while receiving the same antiarrhythmic regimen. Although the exacerbation was transient in some patients, six required different antiarrhythmic therapy and one eventually died. Two additional patients had frequent and prolonged episodes of nonsustained ventricular tachycardia that could trigger the defibrillator, requiring changes in the antiarrhythmic regimen. Another patient had progressive cardiac failure and died on day 5. A marked (sevenfold) increase in asymptomatic ventricular arrhythmias was noted in 42% of the remaining 35 patients. In group 2 (combined surgery), one patient developed refractory ventricular tachycardia 3 days postoperatively and died on that day. Three patients developed frequent nonsustained ventricular tachycardia postoperatively, requiring changes in the antiarrhythmic regimen. The overall surgical mortality rate was 4.4% (4.3% in group 1 and 4.5% in group 2) and was due to refractory ventricular tachycardia in two patients and cardiac failure in one.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗