PubMed Health⌕ Search

Biomedical subjects

K Joos

Publications and source records attributed to K Joos.

8 recordsLinked to original sources

Acute IOP elevation with scleral suction: effects on retrobulbar haemodynamics.

AIMS/BACKGROUND: Mechanical and vascular factors may both contribute to glaucoma. This study investigated the relation of mechanical to vascular factors by examining how acute IOP elevation altered flow velocities in the central retinal and ophthalmic arteries. METHODS: IOP was elevated from a baseline near 14 to approximately 45 mm Hg using suction ophthalmodynamometry. During recovery from scleral suction, IOP fell to near 8 mm Hg. At each IOP, peak systolic and end diastolic velocities (PSV and EDV) were measured in the central retinal and ophthalmic arteries using colour Doppler imaging (Siemens Quantum 2000). Eleven healthy people served as subjects. RESULTS: Acute elevation in IOP had no effect upon PSV, EDV, or the derived resistance index in the ophthalmic artery: flow velocities in this vessel were identical at IOP of 8 mm Hg or 45 mm Hg. In contrast, in the central retinal artery, PSV and EDV fell, and the resistance index rose, in steady progression as IOP was acutely elevated (each p < 0.01). At IOP of 45 mm Hg, EDV was virtually absent and the resistance index was very nearly 1.0. CONCLUSION: Ophthalmic arterial haemodynamics are unrelated to acute fluctuations of the IOP over a wide range, suggesting that ocular hypertension itself cannot induce vascular dysfunction in this artery. In contrast, flow velocities in the central retinal artery were highly IOP dependent, implying that haemodynamic and mechanical factors are closely linked in this vascular bed.

Acute Disease↗

Laser Doppler flowmetry measurement of changes in human optic nerve head blood flow in response to blood gas perturbations.

PURPOSE: The objective of this study was to establish the ability of laser Doppler flowmetry to detect relative changes in human optic nerve head hemodynamics caused by physiologic blood gas perturbations. METHODS: Laser Doppler flowmetry permits the noninvasive assessment of relative blood velocity, volume, and flow (flux) in a sample volume of the nerve head. Such measurements were performed in two groups of healthy subjects. The first group (n = 11) was tested during normal room air breathing and then while breathing 100% oxygen (isocapnic hyperoxia). The second group (n = 10) was also tested under normal conditions as well as during isoxic hypercapnia (+ 15% end-tidal carbon dioxide). Results were analyzed by paired t tests. RESULTS: Hyperoxia created a significant 25% (p = 0.002) decrease in optic nerve head blood flow, with blood volume decreased by 9% (p = 0.095) and blood velocity reduced by 13% (p = 0.154) compared to the room air condition. During hypercapnia, optic nerve head blood flow was increased by 28% (p = 0.012), with blood volume increased by 22% (p = 0.017) and blood velocity increased by 9% (p = 0.218) as compared to the normal room air condition. CONCLUSION: Blood flow in the optic nerve head capillaries changes in response to hyperoxia and hypercapnia as demonstrated in the brain and retina. Laser Doppler flowmetry permits the noninvasive assessment of these responses in humans under conditions within the physiologic range.

Adult↗

Microarteriorrhaphy: blood flow after wound healing.

The present study tests the hypothesis that early wound healing effects blood flow after experimental microarteriorrhaphy. Hemodynamic variables were measured in the rat femoral artery prior to and 3 weeks after both interrupted and continuous microarteriorrhaphy techniques. The hemodynamic variables (blood velocities, lumen geometry, and calculated blood flow) were measured by 20-MHz pulsed ultrasonic Doppler velocity meter (PUDVM) methods. The control values (N = 22) and the 3 weeks postoperative values, for both the interrupted (N = 11) and continuous groups (N = 11), were not statistically different (P greater than .01). The average calculated blood flows were as follows: control group 10.85 +/- 1.45 cc/min, interrupted group 12.01 +/- .92 cc/min, and continuous group 8.50 +/- 1.45 cc/min. Three weeks of wound healing after microarteriorrhaphy did not significantly change blood flow variables compared to preoperative values.

Animals↗

Interrupted and continuous microarteriorrhaphy techniques: a hemodynamic comparison.

The purpose of this study was to compare interrupted and continuous suturing techniques in laboratory microarteriorrhaphy. The comparison was based on rat femoral artery hemodynamic variables, including blood velocities, lumen diameters, and calculated blood flow. These variables were calculated by an offline computer from Doppler frequency shifts that were measured by a 20-MHz pulsed ultrasonic Doppler velocity meter. No statistical difference was noted postoperatively between the interrupted and continuous techniques relative to any hemodynamic variable. Average blood flow after the interrupted (n = 12) and continuous (n = 12) techniques was 6.59 +/- 1.12 and 6.74 +/- 1.20 ml/min, respectively. The two microarteriorrhaphy techniques result in equal postoperative vessel hemodynamics in a laboratory model.

Animals↗