PubMed · 6396386
Interrupted and continuous microarteriorrhaphy techniques: a hemodynamic comparison.
Abstract
The purpose of this study was to compare interrupted and continuous suturing techniques in laboratory microarteriorrhaphy. The comparison was based on rat femoral artery hemodynamic variables, including blood velocities, lumen diameters, and calculated blood flow. These variables were calculated by an offline computer from Doppler frequency shifts that were measured by a 20-MHz pulsed ultrasonic Doppler velocity meter. No statistical difference was noted postoperatively between the interrupted and continuous techniques relative to any hemodynamic variable. Average blood flow after the interrupted (n = 12) and continuous (n = 12) techniques was 6.59 +/- 1.12 and 6.74 +/- 1.20 ml/min, respectively. The two microarteriorrhaphy techniques result in equal postoperative vessel hemodynamics in a laboratory model.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
W F Blair, D R Pedersen, K Joos, D Bondi. 1984. Interrupted and continuous microarteriorrhaphy techniques: a hemodynamic comparison.. https://doi.org/10.1002/jor.1100020415
Cite the original work for its findings. Save a collection to share your selection of sources.