A self-oscillating detuning-insensitive class-E transmitter for implantable microsystems.

This paper describes a low-cost, self-oscillating, detuning-in-sensitive, class-E driver for transcutaneous power and data transmission to implantable microsystems. A voltage feedback scheme using a fast comparator for zero-crossing detection and a CMOS start-up circuit were used to stabilize the class-E operation for various transmitter coil inductance values. This technique solves the common problem of mismatch between the switching frequency of the driving device and the resonant frequency of the load network, which can cause excessive power loss and damage to the active device. Data is transmitted by AM modulation of the carrier through switching the power supply between two levels. The transmitter uses a 9-V supply, consumes 212 mA, operates at 3.9 MHz, and has an efficiency of 71%. The efficiency is stable (< 2% change) against 13% variations in the inductance value of a pancake shaped transmitter coil. Index Terms-Biomedical microsystems, class-E transmitter, implantable electronics, inductive powering, transcutaneous links.

Electric Power Supplies↗

An ultralight biotelemetry backpack for recording EMG signals in moths.

A two-channel FM biopotential recording system fabricated on a foldable, lightweight, polyimide substrate is presented. Each channel consists of a biopotential amplifier followed by a Colpitts oscillator with operating frequency tunable in the 88-108 MHz commercial FM band. The overall system measures 10 mm X 10 mm X 3 mm, weighs 0.74 g, uses two 1.5-V batteries, dissipates about 2 mW, and has a transmission range of 2 m. Using this system, electromyogram signals have been recorded from the dorsal ventral muscle and the dorsal longitudinal muscle of a giant sphinx moth (manduca sexta).

Animals↗

The biocompatibility, integrity, and positional stability of an injectable microstimulator for reanimation of the paralyzed larynx.

The biocompatibility, integrity, positional stability, and potential use of hermetically sealed injectable wireless micromachined microstimulators were investigated for reanimation of the paralyzed larynx. The device, consisting of silicon and glass, has been tested and proven to be biocompatible with no evidence of pathological tissue reaction or rejection up to one-year implantation in the rat dorsum and canine larynx. By one month, each unit was encapsulated by a thin membrane, which thickened to form a fibrous layer of less than 500 microm at 6-12 months. The microstimulators demonstrated long-term in vivo durability: the hermetic seal of only one in ten devices was breached. Once implanted, migration of the device varied from 0 to 3 cm, depending upon the extent of surgical dissection. No discernable migration was noted when the tissue dissection was minimal. Studies utilizing a modified device equipped with electrodes indicated that migration was nominal with sufficient positional stability to ensure activation of target muscles for glottis opening. This study supported the feasibility of using a microstimulator for reanimation of paralyzed laryngeal muscles that open the airway during breathing. This innovative approach to treatment would alleviate the need for a tracheotomy or surgical resection of the vocal fold.

Animals↗

An all-silicon single-wafer micro-g accelerometer with a combined surface and bulk micromachining process.

This paper reports an all-silicon fully symmetrical z-axis micro-g accelerometer that is fabricated on a single-silicon wafer using a combined surface and bulk fabrication process. The microaccelerometer has high device sensitivity, low noise, and low/controllable damping that are the key factors for attaining micro g and sub-micro g resolution in capacitive accelerometers. The microfabrication process produces a large proof mass by using the whole wafer thickness and a large sense capacitance by utilizing a thin sacrificial layer. The sense/feedback electrodes are formed by a deposited 2-3 microns polysilicon film with embedded 25-35 microns-thick vertical stiffeners. These electrodes, while thin, are made very stiff by the thick embedded stiffeners so that force rebalancing of the proof mass becomes possible. The polysilicon electrodes are patterned to create damping holes. The microaccelerometers are batch-fabricated, packaged, and tested successfully. A device with a 2-mm x 1-mm proof mass and a full bridge support has a measured sensitivity of 2 pF/g. The measured sensitivity of a 4-mm x 1-mm accelerometer with a cantilever support is 19.4 pF/g. The calculated noise floor of these devices at atmosphere are 0.23 micro g/sqrt(Hz) and 0.16 micro g/sqrt(Hz), respectively.

Acceleration↗

A modular micromachined high-density connector system for biomedical applications.

This paper presents a high-density, modular, low-profile, small, and removable connector system developed using micromachining technologies for biomedical applications. This system consists of a silicon or polyimide electrode with one end in contact with the biological tissue and its back-end supported in a titanium base (12.5 mm in diameter and 2.5 mm in height) that is fixed on the test subject. An external glass substrate (6 x 6 x 0.75 mm3), which supports a flexible polyimide diaphragm and CMOS buffers, is attached to the titanium base whenever electrical contact is required. The polyimide flexible diaphragm contains high-density gold electroplated pads (32 pads, each having an area of 100 x 100 micron 2 and separated by 150 microns) which match similar pads on the electrode back-end. When vacuum is applied between the two, the polyimide diaphragm deflects and the corresponding gold pads touch, therefore, establishing electrical connection. In vitro electrical tests in saline solution have been performed on a 32-site connector system demonstrating < 5 omega contact resistance, which remained stable after 70 connections, and -55 dB crosstalk at 1 kHz between adjacent channels. In vivo experiments have also confirmed the establishment of multiple contacts and have produced simultaneous biopotential recordings from the guinea pig occipital cortex.

Animals↗

Long term chronic recordings from peripheral sensory fibers using a sieve electrode array.

The use of an implanted micromachined silicon sieve electrode array to make long term chronic recordings from the glossopharyngeal nerve is described. The implant consists of an array of small holes in a silicon substrate, four of which are surrounded by electrodes connected with an integrally fabricated ribbon cable to a percutaneous headcap. Using this device we have been able to monitor the integrity of the electrodes from the time of implantation and subsequently to record evoked sensory responses from mechanoreceptors on the tongue.

Animals↗

Corneal endothelial toxicity of topical anesthesia.

PURPOSE: To determine the relative corneal endothelial toxicities of the following topical anesthetic agents: bupivacaine HCl 0.75%, unpreserved lidocaine HCl 4%, proparacaine HCl 0.5%, and tetracaine HCl 0.5%. METHODS: The experiment was conducted using pigmented rabbits. Approximately nine animals each were randomly assigned to eight groups. Right eyes received injections of 0.2 ml of one of the four anesthetic agents at one of two concentrations and left eyes received injections of 0.2 ml of balanced salt solution. Corneal thickness and clarity were measured before surgery and on postoperative days 1, 3, and 7. RESULTS: A statistically significant increase (P < 0.05) in corneal thickness and opacification over preoperative measurements was noted with injections of bupivacaine, lidocaine, and proparacaine, controlling for changes occurring in control eyes from surgery alone. Proparacaine was statistically more toxic than were the others. The toxicity of tetracaine was statistically indistinguishable from balanced salt solution, although mild toxicity was evident clinically. Injection of 1:10 dilutions of the same anesthetic agents failed to produce a statistically significant increase in corneal thickness or opacification on any postoperative examination. CONCLUSIONS: Anterior chamber injection of bupivacaine HCl 0.75%, unpreserved lidocaine HCl 4%, and proparacaine HCl 0.5% produces corneal thickening and opacification that is clinically and statistically significant. Tetracaine HCl 0.5% injection produces corneal thickening and opacification that is clinically apparent in some eyes but statistically insignificant. Ophthalmic surgeons should be aware of the potential for endothelial cell injury if anesthetic agents enter or are injected into the eye during cataract surgery in the concentrations supplied commercially.

Administration, Topical↗

Short-term bladder-wall response to implantation of microstimulators.

This study examined the histological response of the bladder wall serosa to the implantation of wireless microstimulators secured with a single polypropylene suture. Two to three microstimulators were implanted in each of three casts for an eight week implantation period to allow sufficient time for a bladder-wall injury-response to develop. Gross observation revealed encapsulation of the microstimulators with no perforation to the bladder lumen or migration from the bladder wall. Histological evaluation confirmed that all the microstimutators were encapsulated with a thin connective tissue sheath and a thickened subserosal layer. There was no remarkable difference in tissue morphology compared with normal bladder wall sections for five of seven stimulators. Two microstimulators in one cat revealed a moderate to severe inflammatory response confined to a small area around the stimulator. In a second cat, a suture extended through the bladder wall. The microstimulators were observed with a scanning electron microscope after explantation. The electrode surfaces, bonding interface between silicon and glass and insulating films that were exposed to biological fluids were carefully inspected. All these observations indicate that the glass capsule reliably protected the sealed cavity of the microstimulators from moisture. These results indicate the microstimulator should be considered for further studies such as effects of stimulation and long-term implantation.

Animals↗

A single-channel implantable microstimulator for functional neuromuscular stimulation.

This paper describes a single-channel implantable microstimulator for functional neuromuscular stimulation. This device measures 2 x 2 x 10 mm3 and can be inserted into paralyzed muscle groups by expulsion from a hypodermic needle. Power and data to the device are supplied from outside by RF telemetry using an amplitude-modulated 2-MHz RF carrier generated using a high-efficiency class-E transmitter. The transmitted signal carries a 5-b address which selects one of the 32 possible microstimulators. The selected device then delivers up to 2 microC of charge store in a tantalum chip capacitor for up to 200 microseconds (10 mA) into loads of < 800 omega through a high-current thin-film iridium-oxide (IrOx) electrode (approximately 0.3 mm2 in area). A bi-CMOS receiver circuitry is used to: generate two regulated voltage supplies (4.5 and 9 V), recover a 2-MHz clock from the carrier, demodulate the address code, and activate the output current delivery circuitry upon the reception of an external command. The overall power dissipation of the receiver circuitry is 45-55 mW. The implant is hermetically packaged using a custom-made glass capsule.

Electric Stimulation Therapy↗

A micromachined silicon sieve electrode for nerve regeneration applications.

A micromachined silicon sieve electrode has been developed and fabricated to record from and stimulate axons/fibers of the peripheral nervous system by utilizing the nerve regeneration principle. The electrode consists of a 15-microns-thick silicon support rim, a 4-microns-thick diaphragm containing different size holes to allow nerve regeneration, thin-film iridium recording/stimulating sites, and an integrated silicon ribbon cable, all fabricated using boron etch-step and silicon micromachining techniques. The thin diaphragm is patterned using reactive ion etching to obtain different size holes with diameters as small as 1 micron and center-center spacings as small as 10 microns. The holes are surrounded by 100-200 microns 2 anodized iridium oxide sites, which can be used for both recording and stimulation. These sites have impedances of less than 100 k omega @ 1 kHz and charge delivery capacities in the 4-6 mC/cm2 range. The fabrication process is single-sided, has high yield, requires only five masks, and is compatible with integrated multilead silicon ribbon cables. The electrodes were implanted between the cut ends of peripheral taste fibers of rats (glossopharyngeal nerve), and axons functionally regenerated through holes, responding to chemical, mechanical, and thermal stimuli.

Animals↗

Silicon ribbon cables for chronically implantable microelectrode arrays.

This paper describes the design, fabrication, and testing of miniature ultraflexible ribbon cables for use with micromachined silicon microprobes capable of chronic recording and/or stimulation in the central nervous system (CNS). These interconnects are of critical importance in reliably linking these microelectrodes to the external world through a percutaneous connector. The silicon cables allow the realization of multilead, multistrand shielded local interconnects that are extremely flexible and yet strong enough to withstand normal handling and surgical manipulation. Cables 5 microns thick, 1-5 cm long, and from 60 to 250 microns wide have been fabricated with up to eight leads. The series lead resistance is typically 4 k omega/cm for polysilicon and 500 omega/cm for tantalum, with shunt capacitance values of 5-10 pF/cm and an interlead capacitance below 10 fF/cm. Soak tests in buffered saline performed under electrical and mechanical stress have been underway for over three years and show subpicoampere leakage levels. Silicon microprobes with built-in ribbon cables have remained functional for up to one year in the guinea pig CNS, recording driven single-unit activity and maintaining impedance levels in the 1-7 M omega range.

Animals↗

Artificial neural networks as adjuncts for assessing medical students' problem solving performances on computer-based simulations.

Artificial neural networks were trained by supervised learning to recognize the test selection patterns associated with students' successful solutions to seven immunology computer-based simulations. New test selection patterns evaluated by the trained neural network were correctly classified as successful or unsuccessful solutions to the problem > 90% of the time. The examination of the neural networks output weights after each test selection revealed a progressive and selective increase for the relevant problem suggesting that a successful solution is represented by the neural network as the accumulation of relevant tests. Unsuccessful problem solutions were classified by the neural network software into two patterns of students performance. The first pattern was characterized by low neural network output weights for all seven problems reflecting extensive searching and lack of recognition of relevant information. In the second pattern, the output weights from the neural network were biased toward one of the remaining six incorrect problems suggesting that the student misrepresented the current problem as an instance of a previous problem. Finally, neural network analysis could detect cases where the students switched hypotheses during the problem solving exercises.

California↗

Functional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays.

To assess the potential of micromachined silicon sieve electrodes for long term recordings from single afferent sensory fibers, we implanted them between the cut ends of rat glossopharyngeal nerves which innervate taste and somatosensory receptors on the posterior tongue. After the implants had been in place for an average of 101 days nerve regeneration was measured using histological and electrophysiological methods. Axons of the glossopharyngeal nerve regenerated through holes in the sieves and supported the functional regeneration of taste, thermal and mechanoreceptors.

Animals↗

Can artificial neural networks provide an "expert's" view of medical students performances on computer based simulations?

Artificial neural networks were trained to recognize the test selection patterns of students' successful solutions to seven immunology computer based simulations. When new student's test selections were presented to the trained neural network, their problem solutions were correctly classified as successful or non-successful > 90% of the time. Examination of the neural networks output weights after each test selection revealed a progressive increase for the relevant problem suggesting that a successful solution was represented by the neural network as the accumulation of relevant tests. Unsuccessful problem solutions revealed two patterns of students performances. The first pattern was characterized by low neural network output weights for all seven problems reflecting extensive searching and lack of recognition of relevant information. In the second pattern, the output weights from the neural network were biased towards one of the remaining six incorrect problems suggesting that the student mis-represented the current problem as an instance of a previous problem.

Allergy and Immunology↗

Microfabrication techniques for integrated sensors and microsystems.

Integrated sensors and actuators are rapidly evolving to provide an important link between very large scale integrated circuits and nonelectronic monitoring and control applications ranging from biomedicine to automated manufacturing. As they continue to expand, entire microsystems merging electrical, mechanical, thermal, optical, magnetic, and perhaps chemical components should be possible on a common substrate.

Biosensing Techniques↗

A low-noise demultiplexing system for active multichannel microelectrode arrays.

This paper reports a low-noise demultiplexing system capable of reconstructing multichannel single-unit neural signals derived from multiplexed microelectrode arrays. The overall multiplexing-demultiplexing system realizes ten channels, a per-channel gain of 68 dB, a bandwidth from 100 Hz to 6 kHz, and an equivalent noise level (referred to the probe input) of 13 microV rms. It provides for signaling over the power supply to allow control of on-chip probe functions such as self-testing. The interchannel crosstalk is less than 3%, and switching noise is suppressed by blanking the transition intervals. The 200 kHz probe sample clock is tracked automatically over a range from 150 to 250 kHz. Neural signals as low as 20 microV (typically 640 microV at the demultiplexing system input) can be reconstructed. The overall system organization is compatible with the demultiplexing of as many as 40 time-multiplexed electrode channels from a single probe data line.

Electric Conductivity↗