Specific coil design for SENSE: a six-element cardiac array.

In sensitivity encoding (SENSE), the effects of inhomogeneous spatial sensitivity of surface coils are utilized for signal localization in addition to common Fourier encoding using magnetic field gradients. Unlike standard Fourier MRI, SENSE images exhibit an inhomogeneous noise distribution, which crucially depends on the geometrical sensitivity relations of the coils used. Thus, for optimum signal-to-noise-ratio (SNR) and noise homogeneity, specialized coil configurations are called for. In this article we study the implications of SENSE imaging for coil layout by means of simulations and imaging experiments in a phantom and in vivo. New, specific design principles are identified. For SENSE imaging, the elements of a coil array should be smaller than for common phased-array imaging. Furthermore, adjacent coil elements should not overlap. Based on the findings of initial investigations, a configuration of six coils was designed and built specifically for cardiac applications. The in vivo evaluation of this array showed a considerable SNR increase in SENSE images, as compared with a conventional array. Magn Reson Med 45:495-504, 2001.

Fourier Analysis↗

Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE).

Diffusion-weighted single-shot EPI (sshEPI) is one of the most important tools for the diagnostic assessment of stroke patients, but it suffers from well known artifacts. Therefore, sshEPI was combined with SENSitivity Encoding (SENSE) to further increase EPI's potential for stroke imaging. Eight healthy volunteers and a consecutive series of patients (N = 8) with suspected stroke were examined with diffusion-weighted SENSE-sshEPI using different reduction factors (1.0 < or = R < or = 3.0). Additionally, a high-resolution diffusion-weighted SENSE-sshEPI scan was included. All examinations were diagnostic and of better quality than conventional sshEPI. No ghostings or aliasing artifacts were discernible, and EPI-related image distortions were markedly diminished. Chemical shift artifacts and eddy current-induced image warping were still present, although to a markedly smaller extent. Measured direction-dependent diffusion-coefficients and isotropic diffusion values were comparable to previous findings but showed less fluctuation. We have demonstrated the technical feasibility and clinical applicability of diffusion-weighted SENSE-sshEPI in patients with subacute stroke. Because of the faster k-space traversal, this novel technique is able to reduce typical EPI artifacts and increase spatial resolution while simultaneously remaining insensitive to bulk motion.

Adult↗

Advances in sensitivity encoding with arbitrary k-space trajectories.

New, efficient reconstruction procedures are proposed for sensitivity encoding (SENSE) with arbitrary k-space trajectories. The presented methods combine gridding principles with so-called conjugate-gradient iteration. In this fashion, the bulk of the work of reconstruction can be performed by fast Fourier transform (FFT), reducing the complexity of data processing to the same order of magnitude as in conventional gridding reconstruction. Using the proposed method, SENSE becomes practical with nonstandard k-space trajectories, enabling considerable scan time reduction with respect to mere gradient encoding. This is illustrated by imaging simulations with spiral, radial, and random k-space patterns. Simulations were also used for investigating the convergence behavior of the proposed algorithm and its dependence on the factor by which gradient encoding is reduced. The in vivo feasibility of non-Cartesian SENSE imaging with iterative reconstruction is demonstrated by examples of brain and cardiac imaging using spiral trajectories. In brain imaging with six receiver coils, the number of spiral interleaves was reduced by factors ranging from 2 to 6. In cardiac real-time imaging with four coils, spiral SENSE permitted reducing the scan time per image from 112 ms to 56 ms, thus doubling the frame-rate.

Brain↗

Sensitivity-encoded spectroscopic imaging.

Sensitivity encoding (SENSE) offers a new, highly effective approach to reducing the acquisition time in spectroscopic imaging (SI). In contrast to conventional fast SI techniques, which accelerate k-space sampling, this method permits reducing the number of phase encoding steps in each phase encoding dimension of conventional SI. Using a coil array for data acquisition, the missing encoding information is recovered exploiting knowledge of the distinct spatial sensitivities of the individual coil elements. In this work, SENSE is applied to 2D spectroscopic imaging. Fourfold reduction of scan time is achieved at preserved spectral and spatial resolution, maintaining a reasonable SNR. The basic properties of the proposed method are demonstrated by phantom experiments. The in vivo feasibility of SENSE-SI is verified by metabolic imaging of N-acetylaspartate, creatine, and choline in the human brain. These results are compared to conventional SI, with special attention to the spatial response and the SNR.

Brain↗

Sensitivity encoded cardiac MRI.

Imaging speed is a key factor in most cardiovascular applications of magnetic resonance imaging. Recently, simultaneous signal acquisition with multiple coils has received increasing attention as a means of enhancing scan speed in MRI. Based on this approach, the sensitivity encoding technique SENSE enables substantial scan time reduction by exploiting the inherent spatial encoding effect of receiver coil sensitivity. This work studies the benefit of sensitivity encoding for cardiovascular MRI. SENSE is applied to accelerate common breath-hold imaging as well as real-time imaging by factors up to 3.2. In the breath-hold mode with ECG triggering, this speed benefit has been used both for reducing the breath-hold interval and for improving spatial resolution. In cardiac real-time imaging without triggering and breath control, the SENSE approach has enabled significantly enhanced temporal resolution, ranging down to 13 ms (77 frames/s). Cardiac real-time SENSE is demonstrated in several modes, including real-time imaging of three parallel slices at a rate of 25 triple frames per second.

Electrocardiography↗

Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme.

Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest as well as under physiological stress. Sample images are presented with scan times per image down to 13 msec at a spatial resolution of 4.1 mm, and 27 msec at a resolution of 2.6 mm. Moreover, multiple slice real-time imaging is demonstrated at a rate of 38 double-frames per second.

Artifacts↗

Contrast-enhanced 3D MRA using SENSE.

Sensitivity encoding (SENSE) was used to improve the performance of three-dimensional contrast-enhanced magnetic resonance angiography (3D CE-MRA). Utilizing an array of receiver coils for sensitivity encoding, the encoding efficiency of gradient-echo imaging was increased by factors of up to three. The feasibility of the approach was demonstrated for imaging of the abdominal vasculature. On the one hand, using a SENSE reduction factor of two, the spatial resolution of a breath-hold scan of 17 seconds was improved to 1.0 x 2.0 x 2.0 mm(3). On the other hand, using threefold reduction, time-resolved 3D CE-MRA was performed with a true temporal resolution of 4 seconds, at a spatial resolution of 1.6 x 2.1 x 4.0 mm(3). CE-MRA with SENSE was performed in healthy volunteers and patients and compared with a standard protocol. Throughout, diagnostic quality images were obtained, showing the ability of sensitivity encoding to enhance spatial and/or temporal resolution considerably in clinical angiographic examinations.

Aged↗

PRESTO-SENSE: an ultrafast whole-brain fMRI technique.

A new ultrafast MR imaging method is proposed and tested, which enables whole-brain fMRI with a true temporal resolution of 1 sec. The method combines a 3D PRESTO pulse sequence with the concept of sensitivity-encoding with multiple receiver coils (SENSE). The so-called PRESTO-SENSE technique is demonstrated on a set of functional block-type motor and visual experiments and compared with conventional functional imaging techniques, such as PRESTO and EPI. Comparable image quality and activation areas are found with all sequences. The noise characteristics of the proposed method are analyzed in detail and their implications for ultrafast fMRI studies are discussed. Magn Reson Med 43:779-786, 2000.

Brain↗

Transfer insensitive labeling technique (TILT): application to multislice functional perfusion imaging.

Cerebral blood flow can be studied in a multislice mode with a recently proposed perfusion sequence using inversion of water spins as an endogenous tracer without magnetization transfer artifacts. The magnetization transfer insensitive labeling technique (TILT) has been used for mapping blood flow changes at a microvascular level under motor activation in a multislice mode. In TILT, perfusion mapping is achieved by subtraction of a perfusion-sensitized image from a control image. Perfusion weighting is accomplished by proximal blood labeling using two 90 degrees radiofrequency excitation pulses. For control preparation the labeling pulses are modified such that they have no net effect on blood water magnetization. The percentage of blood flow change, as well as its spatial extent, has been studied in single and multislice modes with varying delays between labeling and imaging. The average perfusion signal change due to activation was 36.9 +/- 9.1% in the single-slice experiments and 38.1 +/- 7.9% in the multislice experiments. The volume of activated brain areas amounted to 1.51 +/- 0.95 cm3 in the contralateral primary motor (M1) area, 0.90 +/- 0.72 cc in the ipsilateral M1 area, 1.27 +/- 0.39 cm3 in the contralateral and 1.42 +/- 0.75 cm3 in the ipsilateral premotor areas, and 0.71 +/- 0.19 cm3 in the supplementary motor area.

Artifacts↗

SENSE: sensitivity encoding for fast MRI.

New theoretical and practical concepts are presented for considerably enhancing the performance of magnetic resonance imaging (MRI) by means of arrays of multiple receiver coils. Sensitivity encoding (SENSE) is based on the fact that receiver sensitivity generally has an encoding effect complementary to Fourier preparation by linear field gradients. Thus, by using multiple receiver coils in parallel scan time in Fourier imaging can be considerably reduced. The problem of image reconstruction from sensitivity encoded data is formulated in a general fashion and solved for arbitrary coil configurations and k-space sampling patterns. Special attention is given to the currently most practical case, namely, sampling a common Cartesian grid with reduced density. For this case the feasibility of the proposed methods was verified both in vitro and in vivo. Scan time was reduced to one-half using a two-coil array in brain imaging. With an array of five coils double-oblique heart images were obtained in one-third of conventional scan time. Magn Reson Med 42:952-962, 1999.

Brain↗