Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme.

Abstract

Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest as well as under physiological stress. Sample images are presented with scan times per image down to 13 msec at a spatial resolution of 4.1 mm, and 27 msec at a resolution of 2.6 mm. Moreover, multiple slice real-time imaging is demonstrated at a rate of 38 double-frames per second.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Weiger, K P Pruessmann, P Boesiger. 2000. Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme.. https://doi.org/10.1002/(sici)1522-2594(200002)43%3A2%3C177%3A%3Aaid-mrm3%3E3.0.co%3B2-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

The cell in absence of aggregation artifacts.

Eduard Kellenberger understood that the conventional resin-embedding, he helped to develop (Ryter, A., Kellenberger, E., 1958. L'inclusion au polyester pour l'ultramicrotomie. J. Ultrastruct. Res. , 2, 200-214), was prone to aggregation artifacts (Kellenberger, E., 1987. The response to biological macromolecules and supramolecular structures to the physics of specimen cryo-preparation. In: Steinbrecht, R.A., Zierold, K. (Eds.), Cryo-techniques in Biological Electron Microscopy, Springer, Berlin, pp. 35-63). He was instrumental in developing various methods to overcome this limitation, for instance, by using low temperature-embedding and partially hydrophilic resins (Carlemalm, E., Garavito, R.M., Villiger, W., 1982. Resin development for electron microscopy and an analysis of embedding at low temperature. J. Microstruct., 126, 123-143; Villiger,W., 1993. Low temperature-embedding with Lowicryl resins. In: Robards, A.W., Wilson, A.J. (Eds.), Procedures in electron microscopy, Wiley, Chichester, UK, pp. 16:7.3-16:7.6). In principle, cryo-electron microscopy of vitreous sections is free of any aggregation artifact since the material remains fully hydrated and is free of chemical fixation or staining. The method is technically difficult still, but recent progress has made it amenable to routine practical applications. We compare here electron microscopical aspects of Zea mays meristem cells prepared by: (1) conventional resin-embedding and sectioning; (2) low temperature-embedding and sectioning of freeze substituted samples; and (3) cryo-sections of vitrified samples. The appearance of the extra-cellular space, the cytoplasm and the nucleoplasm are very different in conditions (1) and (3). They appear as compact, irregular and well delineated structures in conventional resin sections, whereas they are more diffuse and homogeneous in the vitreous sections. In the resin sections, the material seems to form a complex matrix, whereas it looks more like a thick soup in the vitreous sample. Low temperature-embedding (condition 2) shows an intermediate appearance. We suggest that regardless of the difference due to staining and different sectioning conditions, the other image differences are the consequence of aggregation artifacts in the resin-embedded specimens.

Artifacts↗

Interactions of Escherichia coli RNA with bacteriophage MS2 coat protein: genomic SELEX.

Genomic SELEX is a method for studying the network of nucleic acid-protein interactions within any organism. Here we report the discovery of several interesting and potentially biologically important interactions using genomic SELEX. We have found that bacteriophage MS2 coat protein binds several Escherichia coli mRNA fragments more tightly than it binds the natural, well-studied, phage mRNA site. MS2 coat protein binds mRNA fragments from rffG (involved in formation of lipopolysaccharide in the bacterial outer membrane), ebgR (lactose utilization repressor), as well as from several other genes. Genomic SELEX may yield experimentally induced artifacts, such as molecules in which the fixed sequences participate in binding. We describe several methods (annealing of oligonucleotides complementary to fixed sequences or switching fixed sequences) to eliminate some, or almost all, of these artifacts. Such methods may be useful tools for both randomized sequence SELEX and genomic SELEX.

Artifacts↗