Effect of anterior capsule polishing on the posterior capsule opacification-inhibiting properties of a sharp-edged, 3-piece, silicone intraocular lens: three- and 5-year results of a randomized trial.

PURPOSE: To evaluate the long-term effects of anterior capsule polishing on regeneratory posterior capsule opacification (PCO), anterior capsule opacification (ACO), and fibrotic PCO with a silicone intraocular lens (IOL) with sharp optic edges. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: This prospective bilateral randomized patient- and examiner-masked clinical trial comprised 130 eyes of 65 patients with bilateral age-related cataract. All eyes had implantation of a 3-piece silicone IOL with a truncated, sharp-edged optic (CeeOn Edge 911A, Advanced Medical Optics). In 1 eye, the anterior capsule was extensively polished using an aspiration curette after phacoemulsification and cortex aspiration. Regenerative PCO was quantified objectively, while ACO and fibrotic PCO were graded subjectively 1, 2, 3, and 5 years postoperatively. RESULTS: The mean ACO score was significantly lower in the eyes in which the anterior capsule had been polished (1 year, P<.02; 2 years, P<.03; 3 years, P<.01; 5 years, P<.01). The mean difference in regeneratory PCO and fibrotic PCO scores between the 2 groups was not statistically significant. CONCLUSIONS: Three years after cataract surgery, eyes in which the anterior capsule had been polished had significantly less ACO. However, polishing did not lower PCO intensity when a sharp-edged CeeOn 911A IOL was implanted in the bag. Although results indicate that anterior capsule polishing may enhance the development of regeneratory PCO, this trend did not reach statistical significance.

Cataract↗

Comparison of partial coherence interferometers: Acmaster versus laboratory prototype.

PURPOSE: To evaluate anterior segment biometry using the ACMaster (Carl Zeiss Meditec AG, Jena, Germany) in regard to precision of measurement and clinical performance compared to the original laboratory prototype of the partial coherence interferometry technique. METHODS: Ten phakic (20 eyes) and 27 pseudophakic (44 eyes) patients were included in this study. Anterior segment biometry of phakic and pseudophakic study eyes was performed using the ACMaster and the laboratory prototype of the partial coherence interferometry technique. The ACMaster is a commercially available device based on the partial coherence interferometry technique, which provides high precision anterior segment measurements in a quick and user-friendly fashion. Examination included measurement of central corneal thickness, anterior chamber depth, and lens thickness, the latter only in the phakic eyes. RESULTS: The consistency of anterior segment measurements performed with both units was excellent in phakic as well as in pseudophakic eyes. In pseudophakic eyes, the measurement of anterior chamber thickness and lens thickness with the ACMaster produced several (typical) measurement artifacts in some cases, which partially aggravated the identification of the A-scan peak representing the anterior intraocular lens surface. CONCLUSIONS: The ACMaster is a user-friendly device that enables axial anterior segment biometry using the partial coherence interferometry technique with a reproducibility similar to that of the original laboratory prototype.

Anterior Eye Segment↗

Comparison of pilocarpine-induced and stimulus-driven accommodation in phakic eyes.

With the recent introduction of potentially accommodative intraocular lenses (IOL), there is a need for methods to evaluate their accommodative potential. In most studies assessing IOL movement, pilocarpine is used to stimulate contraction of the ciliary muscle. The aim of this study is to determine if pilocarpine-induced ciliary muscle contraction is comparable to physiological stimulus-driven accommodation in young and presbyopic subjects. Ten emmetropic young subjects (23-25 years) and 11 emmetropic presbyopic subjects (51-62 years) were included in this study. Anterior chamber depth (ACD) and lens thickness (LT) were assessed with partial coherence interferometry (PCI). A moveable stimulus was coupled to the PCI equipment for measurement of biometric lens changes. ACD was measured with the stimulus at infinity and then at the subjects individual nearpoint, and after application of two drops of 2% pilocarpine. In young subjects, there was no significant difference in lens change between nearpoint and pilocarpine stimulation. Presbyopic subjects showed no relevant lens change when accommodating at the nearpoint, however, under pharmacologically induced ciliary muscle contraction with pilocarpine, there was a significant forward shift of the anterior and posterior lens pole, leading to a translational forward lens shift of about 150 microm. This study demonstrates that pilocarpine acts "physiologically" in young phakic subjects, but is a "superstimulus" in presbyopic phakic subjects. Therefore, IOL movement may be overestimated when using pilocarpine to stimulate accommodation.

Accommodation, Ocular↗

Change in IOL position and capsular bag size with an angulated intraocular lens early after cataract surgery.

PURPOSE: To investigate the axial movement in the first postoperative week and the influence of capsular bag size with an angulated, 3-piece, open-loop, acrylic intraocular lens (IOL). SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: Twenty-nine eyes of 29 patients with age-related cataract were included in this study. In study 1, an open-loop, 3-piece IOL (AR40e, AMO) was implanted in a standardized fashion in 15 eyes of 15 patients. In study 2, before IOL implantation, a capsular tension ring (CTR) was inserted (14 eyes of 14 patients). Anterior chamber depth (ACD) was assessed with partial coherence interferometry 2 hours; 1, 3, and 5 days; 1 week; and 1 month postoperatively. The capsular bag diameter (CBD) was assessed using gonioscopic measurement of the eyelets of the CTR 1 day, 1 week, and 1 month postoperatively. RESULTS: In the first postoperative week, there was a significant mean forward movement of -196 microm +/- 117 (SD) (P < .005) in study 1 and -139 +/- 97 microm in study 2 (P < .005). These movements correspond to refractive changes of -0.31 diopter (D) and -0.20 D, respectively. The movement was linear in the first 5 days after surgery. Different patterns of early postoperative movement were seen, illustrating interindividual variability. A significant correlation of 0.67 (P < .05) was found between the change in ACD and CBD. CONCLUSIONS: A linear forward movement of the IOL during the first postoperative week was followed by a relatively stable IOL position. Loss of haptic memory seemed to be the most likely cause. Myopic eyes with large capsular bags showed less IOL shift in the early postoperative period than hyperopic eyes with smaller capsular bags.

Adult↗

Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification.

PURPOSE: To compare the posterior capsule opacification (PCO) inhibiting effect of the sharp posterior optic edge design of the Sensar OptiEdge AR40e intraocular lens (IOL) with that of the double-round edge design of the Sensar AR40 IOL over a period of 3 years. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: Fifty-three patients with bilateral age-related cataract (106 eyes) were included in this randomized prospective bilateral patient- and examiner-masked clinical trial with intraindividual comparison. Each study patient had cataract surgery in both eyes and received a Sensar AR40 IOL (anterior and posterior round optic edges) in 1 eye and a Sensar OptiEdge AR40e IOL (round anterior and sharp posterior optic edge) in the other eye. Follow-up examinations were at 1 week, 1 and 6 months, and 1, 2, and 3 years. Digital retroillumination images were taken of each eye. The amount of PCO was assessed subjectively at the slitlamp and objectively using automated image-analysis software (AQUA) 1, 2, and 3 years after surgery. RESULTS: The sharp-edged AR40e lens showed significantly less regeneratory and fibrotic PCO 1, 2, and 3 years after surgery. The mean AQUA PCO score was 2.18 for the AR40 and 1.00 for the AR40e lens after 1 year; 2.94 and 1.56 after 2 years, and estimated at 3.13 and 1.77, respectively, after 3 years (scale 0 to 10; P<.001). The neodymium:YAG laser capsulotomy rate was significantly higher in the AR40 group. The AR40e lens also led to less peripheral fibrotic PCO. There was no significant difference in complaints concerning edge glare between the groups. CONCLUSION: Compared with the AR40 IOL, the sharp posterior optic edge design of the Sensar OptiEdge AR40e IOL led to significantly less PCO 1, 2, and 3 years postoperatively. In contrast with most past studies on PCO-preventative factors, this study varied only 1 parameter, namely the optic edge design, and the main outcome measure (PCO) was assessed with an objective image-analysis system.

Acrylic Resins↗

Pilocarpine-induced shift of an accommodating intraocular lens: AT-45 Crystalens.

PURPOSE: To measure the shift of an accommodating plate-haptic intraocular lens (IOL) along the visual axis induced by ciliary muscle contraction after application of pilocarpine. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: Fifty-four eyes of 28 patients with age-related cataract comprised this prospective study. Each patient received an AT-45 silicone accommodating IOL (Crystalens, Eyeonics Corp.) after standardized cataract surgery. In a subgroup of 24 eyes, capsular bag fibrosis was reduced by extensive polishing of the anterior capsule with a slit cannula. Assessment included measurements of anterior chamber depth, assessed with partial coherence interferometry, before and after application of pilocarpine 2% and evaluation of near visual acuity 1 month and 3 months postoperatively. RESULTS: A slight backward shift of the IOL of 151 mum in the nonpolished group (P < .001) and 122 mum in the polished group (P < .005) could be detected after application of pilocarpine. Polishing the capsule did not influence IOL shift. The median near visual acuity with distance correction 1 month and 3 months postoperatively was J5 and J4, respectively, in the nonpolished group and J6 at both times in the polished group. CONCLUSIONS: Pilocarpine induced a counterproductive active backward shift of the AT-45 IOL. Polishing of the capsular bag had no impact on accommodative ability. The reading performance of patients with the AT-45 IOL patients at 1 and 3 months was not significantly different from that of with a standard IOL under similar testing methods.

Accommodation, Ocular↗

Effect of anterior capsule polishing on posterior capsule opacification and neodymium:YAG capsulotomy rates: three-year randomized trial.

PURPOSE: To compare the long-term effect of extensive polishing and nonpolishing of the anterior lens capsule on posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG) capsulotomy rates. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: This prospective randomized bilateral double-masked study included 108 eyes of 54 consecutive patients with age-related cataract. Following phacoemulsification, 3-piece intraocular lenses (IOLs) with round-edged silicone optics were implanted. Patients received an Allergan SI-40 IOL with a truncated, round optic edge or a Domilens Silens6 IOL with a fully round optic edge. Patients were randomly assigned to have extensive anterior capsule polishing with the Menapace aspiration curette or no treatment in the first eye; the second eye received the opposite treatment. Digital retroillumination images were taken at 1 week, 1 year, and 3 years, and Nd:YAG capsulotomy rates were evaluated. Posterior capsule opacification was objectively scored using automated image analysis software (AQUA) or estimated based on clearly defined assumptions if a capsulotomy had been performed. RESULTS: Thirty-nine patients (78 eyes) concluded the study. Three-year PCO scores after polishing did not differ significantly (P>.05). However, 21 polished eyes (53.8%) required Nd:YAG laser capsulotomy compared with 14 nonpolished eyes (35.9%). The mismatch between PCO scores and Nd:YAG rates resulted from a change in PCO morphology that is not detected by scoring methods based on retroillumination photography but is visually disturbing to patients. CONCLUSIONS: Polishing the anterior capsule was effective in reducing fibrotic opacification but ineffective in reducing regeneratory opacification. Changes in regeneratory PCO morphology not picked up by retroillumination photography increased the need for Nd:YAG laser capsulotomy.

Cataract↗

Influence of optic edge design and anterior capsule polishing on posterior capsule fibrosis.

PURPOSE: To evaluate the role of posterior optic edge design and the effect of anterior capsule polishing on peripheral fibrotic posterior capsule opacification (PCO). SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This randomized prospective study comprised 144 eyes of 72 patients with bilateral age-related cataract. Each patient had standardized cataract surgery in both eyes by the same surgeon. Group 1 (46 patients) received a round-edged hydrophobic acrylic IOL (AMO Sensar AR40) in 1 eye and a sharp-edged hydrophobic acrylic IOL (AMO Sensar OptiEdge AR40e) in the other eye. Group 2 (26 patients) received a silicone IOL (Pharmacia CeeOn 911A) with a truncated optic in both eyes. In this group, the anterior capsule was extensively polished in 1 eye and was left unpolished in the other eye. Digital slitlamp photographs were taken 1 year postoperatively using a standardized photographic technique for fibrotic PCO. The intensity of PCO was subjectively graded (score 0 to 4) by 2 masked examiners. RESULTS: Subjective PCO scores correlated well between the 2 examiners (r = 0.88). In Group 1, the mean PCO score was 0.26 for the OptiEdge AR40e IOL and 0.90 for the AR40 IOL (P<.01). In Group 2, the mean PCO score was 0.24 in eyes with a polished capsule and 0.17 in eyes in which the capsule was not polished (P =.31). CONCLUSIONS: The sharp-edged OptiEdge AR40e IOL led to significantly less peripheral fibrotic PCO 1 year postoperatively than the round-edged AR40 IOL. In eyes with the sharp-edged silicone 911A IOL, anterior capsule polishing caused no significant difference in fibrotic PCO.

Acrylic Resins↗

Effect of a silicone intraocular lens with a sharp posterior optic edge on posterior capsule opacification.

PURPOSE: To compare the inhibiting effect on posterior capsule opacification (PCO) of a silicone intraocular lens (IOL) with a sharp posterior optic edge (ClariFlex OptiEdge, Advanced Medical Optics) and a silicone IOL with a round optic edge (PhacoFlex SI-40, Advanced Medical Optics). SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This prospective randomized patient- and examiner-masked study comprised 104 eyes of 52 patients with bilateral age-related cataract. All patients had cataract surgery in both eyes and received a sharp-edged IOL in 1 eye and a round-edged IOL in the other eye. Postoperative examinations were at 1 week, 1 and 6 months, and 1 year. Digital slitlamp and retroillumination images were taken of each eye. The amount of PCO was assessed subjectively at the slitlamp and objectively using Automated Quantification of After-Cataract (AQUA) automated-image analysis software. RESULTS: The sharp-edged IOL group had significantly less regeneratory and fibrotic PCO 1 month, 6 months, and 1 year after surgery. The mean AQUA PCO score (scale 0 to 10) was 0.71 in the sharp-edged IOL group and 1.40 in the round-edged IOL group (P<.001). The sharp-edged IOL group had less peripheral fibrotic PCO. There was no significant difference between the 2 IOL groups in patient reports of edge glare. CONCLUSION: The sharp-edged design of the ClariFlex OptiEdge silicone IOL led to significantly less PCO than the round-edged PhacoFlex SI-40 IOL 1 year postoperatively.

Aged↗

Predicting postoperative intraocular lens position and refraction.

PURPOSE: To predict the postoperative IOL position and refraction as accurately as possible independent of individualization of the parameters. SETTING: Universitats-Augenklinik, Mainz, Germany, and Vienna, Austria. METHODS: One patient cohort (189 eyes, Vienna) was used to calibrate the prediction method, which was then applied to a second cohort (65 eyes, Mainz). All calculations were based on consistent numerical ray tracing of the pseudophakic eye using the original manufacturer's intraocular lens (IOL) data (radii, thickness, refractive index). A new algorithm to predict IOL position was developed. Ultrasound (US) axial lengths were calibrated relative to partial coherence interferometry (PCI). Corneal radii extracted from topography were checked against radii measured with the IOLMaster (Zeiss) and by Littmann keratometry. RESULTS: Zero mean prediction errors for IOL position and refraction were obtained without adjusting the parameters and with PCI lengths or US lengths calibrated relative to the PCI values. There was no significant loss of accuracy of US data compared to PCI data. Corneal radii extracted from topography were slightly but statistically significantly different from the Littmann values, and they were more accurate than the latter with respect to prediction error. The measured mean central IOL position (distance from posterior corneal surface) for all IOL types was 4.580 mm, a value very close to the mean recalculated from A-constants (4.587 mm). The difference in the individual central IOL position relative to the mean value depended only linearly (ie, no higher orders such as square or cubic are needed) on axial length, with the mean central IOL position as a free parameter. This parameter should be 4.6 +/- 0.2 mm (the same value as independently measured or recalculated) to obtain zero steepness of the prediction error as a function of axial length, producing zero bias for long and short eyes. CONCLUSIONS: Calculation errors from formulas and confusing adjusting parameters can be avoided if calculations and measurements are performed on a clear and simple physical basis. Nevertheless, an individual prediction error, typically 0.5 to 1.0 diopter, seems to be unavoidable.

Adult↗

Laserinterferometric assessment of pilocarpine-induced movement of an accommodating intraocular lens: a randomized trial.

PURPOSE: To measure the axial movement of an accommodating intraocular lens (IOL) induced by ciliary muscle contraction after application of pilocarpine. DESIGN: Randomized, controlled, patient- and examiner-masked trial with intrapatient comparison. PARTICIPANTS AND CONTROLS: One hundred ten eyes of 55 patients with age-related bilateral cataract. METHODS: This study was divided into 3 parts. In the first, the accommodating IOL (1CU) was compared with a 3-piece open-loop acrylic IOL that served as the control. In the second, to assess the effect of capsule fibrosis on the potential accommodating performance of the accommodating IOL, extensive polishing of the anterior capsule with a slit cannula was compared with standard surgery. In the third, the effect of a posterior capsulorhexis was compared with that of standard surgery. Anterior chamber depth (ACD) was assessed with partial coherence interferometry, measured before and after topical application of pilocarpine 2%, and near visual acuity (VA) was evaluated 3 months after surgery. MAIN OUTCOME MEASURE: Pilocarpine-induced change in ACD. RESULTS: The accommodating IOL showed a forward movement under pilocarpine with a median amplitude of movement of -314 microm (95% confidence interval [CI]: -148 to -592), compared with the backward movement of 63 microm (95% CI: 161 to -41) for the open-loop control IOL (P = 0.001). Capsule polishing and a posterior capsulorhexis had no effect on IOL movement with the accommodating IOL. The median near VA with distance correction was 20/60. CONCLUSION: Pilocarpine induced a small but significant forward movement of the accommodating IOL. However, the amount of movement was calculated to result in a refractive change of <0.5 diopters (D) in most patients, reaching 1 D or slightly more in only single cases, with a large variability of movement. Neither polishing of the capsule bag nor a posterior capsulorhexis could enhance the accommodative ability.

Accommodation, Ocular↗

Effect of haptic design on change in axial lens position after cataract surgery.

PURPOSE: To compare the postoperative changes in anterior chamber depth (ACD) between single-piece and multipiece AcrySof intraocular lenses (IOLs) (Alcon Laboratories, Inc.) and their effect on the postoperative refractive shift. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This prospective randomized bilateral study with intraindividual comparison comprised 104 eyes of 52 consecutive patients with age-related cataract. All patients had standardized cataract surgery with a temporal self-sealing incision, phacoemulsification, and IOL implantation in the capsular bag. The first 30 patients received a single-piece, 5.5 mm optic IOL (AcrySof SA30) in 1 eye and a multipiece IOL (AcrySof MA30) in the other eye. Another 22 patients received the corresponding 6.0 mm optic models (AcrySof SA60 and AcrySof MA60, respectively). Anterior chamber depth measurements and evaluation of the change in ACD during the first 6 postoperative months were performed using partial coherence laser interferometry. The amount of change in capsulorhexis size during the first 6 postoperative months was assessed using standardized retroillumination photographs. RESULTS: Single-piece IOLs shifted significantly less postoperatively than multipiece IOLs. The multipiece IOLs shifted forward, especially from 1 day to 1 month. The change in the capsulorhexis area was similar between IOL types. CONCLUSIONS: Single-piece AcrySof IOLs shifted minimally after the first postoperative day; therefore, the prescription for spectacles in eyes with this IOL can be obtained soon after surgery.

Anterior Chamber↗

Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes.

PURPOSE: To compare anterior chamber depth (ACD) measurements in phakic and pseudophakic eyes using a slit-beam photographic technique (IOLMaster, Carl Zeiss Meditec AG) with those obtained with the laboratory prototype version of partial coherence interferometry (PCI) and with conventional applanation ultrasound in phakic eyes. SETTING: Department of Ophthalmology, Vienna General Hospital, Vienna University, Vienna, Austria. METHODS: Thirty-three ACDs of 28 patients with age-related cataract were measured preoperatively with a slit-beam photographic technique (IOLMaster) and the prototype version of PCI. In 24 eyes, the ACD was also assessed with applanation ultrasound. In addition, 34 ACDs of 18 pseudophakic patients in a different study population were examined postoperatively with the IOLMaster and PCI. RESULTS: The median ACD in the phakic eyes was 3.06 mm (range 1.93 to 3.90 mm) with the IOLMaster, 3.09 mm with PCI (range 1.49 to 4.06 mm), and 2.87 mm (range 2.18 to 3.33 mm) with applanation ultrasound. The precision was 0.005 mm for PCI and 0.015 mm for IOLMaster measurement. The median difference between the IOLMaster and PCI ACD biometry was 0.01 mm +/- 0.14 (SD) (range -0.44 to 0.17 mm) (P =.71). In pseudophakic eyes, the 2 methods showed a median difference of -0.22 mm (range -0.45 to 1.99 mm) (P >.1) and did not correlate (r = 0.21; P >.2). CONCLUSIONS: In phakic eyes, the difference between IOLMaster and PCI measurements was small and not statistically significant. In pseudophakic eyes, the difference was larger and the methods did not correlate.

Anterior Chamber↗

Postoperative change in effective lens position of a 3-piece acrylic intraocular lens.

PURPOSE: To study the change in postoperative position of an angulated, 3-piece, foldable acrylic intraocular lenses (IOLs) and evaluate the effect of a sharp posterior optic edge compared with that of a round optic edge on the change in postoperative anterior chamber depth (ACD). SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This randomized intraindividual-comparison study comprised 104 eyes of 52 patients with age-related cataract. Patient received a sharp-edged Sensar OptiEdge AR40e IOL (Allergan Surgical) in 1 eye and a round-edged Sensar AR40 IOL in the other eye. Postoperative follow-up included ACD measurement by partial coherence interferometry and evaluation of the capsulorhexis area by standardized retroillumination photography at 1 day, 1 week, and 1 and 6 months. RESULTS: A decrease in ACD during the first postoperative week was followed by a small increase in ACD during the first 6 months. There was no significant difference between the sharp-edged group and the round-edged group. CONCLUSIONS: The angulated 3-piece acrylic IOLs showed significant forward movement over the first postoperative 6 months. Although the change in refraction was small, there was variability among patients. The sharp posterior optic edge design did not affect the IOL's movement in the capsular bag.

Acrylic Resins↗

Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery.

PURPOSE: To compare measurements performed with the IOLMaster (Carl Zeiss, Meditec AG) with those obtained by applanation ultrasound (US) and manual keratometry and to evaluate the effect of operator experience on US biometry. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: The axial length (696 eyes) and anterior chamber depth (ACD) (462 eyes) were measured in 377 patients with cataract using the IOLMaster and applanation US. To assess the effect of operator experience on the biometric results, the operators were divided into 2 groups: experienced and less experienced in performing US biometry. The difference in measurements between the methods and the variability of the difference were compared between the 2 groups. RESULTS: Applanation US measured axial length and ACD shorter than the IOLMaster; the mean numerical difference was 0.13 mm and 0.19 mm, respectively (P<.01). For axial length, the absolute difference was smaller with experienced operators than with less experienced operators (0.15 mm versus 0.22 mm) (P<.01). For ACD, experienced operators obtained a smaller difference between measurement techniques (0.21 mm versus 0.29 mm; P<.05). CONCLUSIONS: Experienced US operators had less difference and lower variability in the difference between applanation US and IOLMaster readings for axial length and ACD measurements. The noncontact optical method, which is essentially operator independent, gave significantly more reliable biometry before cataract surgery, especially in the case of less experienced operators.

Adult↗

Determining postoperative anterior chamber depth.

PURPOSE: To compare measured and calculated postoperative anterior chamber depths (ACDs). SETTING: Department of Ophthalmology and Institute of Medical Physics, University of Vienna, Vienna, Austria, and Department of Ophthalmology, University of Mainz, Mainz, Germany. METHODS: The postoperative ACD was measured in 189 pseudophakic eyes using a laboratory prototype of partial coherence interferometry (PCI). In 6 intraocular lens (IOL) groups, the mean ACD was calculated by ray tracing based on the best-known A-constants of the SRK formulas. In addition, for each IOL type, each measured ACD was compared with a value calculated using the individual spherical equivalent of the postoperative refraction. RESULTS: The measured and the calculated ACD values were close and did not show systematic differences. The ACD values obtained in the study, however, differed significantly from the values published by the IOL manufacturers. A comparison of the PCI-assessed ACDs and the calculated values using the postoperative refraction showed more scattered results for the refraction-based data, which was probably the result of higher measurement errors with the autorefractometer than with PCI. CONCLUSIONS: High-precision interferometry measurements and ray-tracing calculations confirmed each other. The resulting mean ACD values should be used instead of the manufacturers' values. The refractive outcome of cataract surgery can be improved by combining preoperative high-precision PCI biometry and numerical ray tracing for IOL power calculations.