Determining postoperative anterior chamber depth.

Abstract

PURPOSE: To compare measured and calculated postoperative anterior chamber depths (ACDs). SETTING: Department of Ophthalmology and Institute of Medical Physics, University of Vienna, Vienna, Austria, and Department of Ophthalmology, University of Mainz, Mainz, Germany. METHODS: The postoperative ACD was measured in 189 pseudophakic eyes using a laboratory prototype of partial coherence interferometry (PCI). In 6 intraocular lens (IOL) groups, the mean ACD was calculated by ray tracing based on the best-known A-constants of the SRK formulas. In addition, for each IOL type, each measured ACD was compared with a value calculated using the individual spherical equivalent of the postoperative refraction. RESULTS: The measured and the calculated ACD values were close and did not show systematic differences. The ACD values obtained in the study, however, differed significantly from the values published by the IOL manufacturers. A comparison of the PCI-assessed ACDs and the calculated values using the postoperative refraction showed more scattered results for the refraction-based data, which was probably the result of higher measurement errors with the autorefractometer than with PCI. CONCLUSIONS: High-precision interferometry measurements and ray-tracing calculations confirmed each other. The resulting mean ACD values should be used instead of the manufacturers' values. The refractive outcome of cataract surgery can be improved by combining preoperative high-precision PCI biometry and numerical ray tracing for IOL power calculations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Katharina Kriechbaum, Oliver Findl, Paul Rolf Preussner, Christina Köppl, Jochen Wahl, Wolfgang Drexler. 2003. Determining postoperative anterior chamber depth.. https://doi.org/10.1016/s0886-3350(03)00414-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Model of pulsatile-flow of aqueous humor through the iris-lens canal.

PURPOSE: To present a model of pulsatile-flow of aqueous humor from posterior (PC) to anterior chamber (AC) and to analyze the sensitivity of this novel model in detecting typical high risk conditions predisposing to pupillary block. METHODS: The model assumes noncontinuous flow of aqueous through the iris-lens canal. Aqueous that fills the canal will be ejected toward the AC-side of the canal at certain time intervals, and between 2 events of aqueous ejection there is no actual flow through this canal. Pupillary pumping rate (PPR) was calculated from the aqueous flow rate and the calculated volume of iris-lens canal. RESULTS: PPR values were generated by incorporating pupillary diameter (1 to 8 mm), aqueous flow rate (1 to 2.5 microL/min), and iris-lens canal width (0.5 to 2 mm) and height (3-9 microm) in numerical experimentation with the present model. PPR showed inverse dependence on iris-lens canal height and pupillary diameter and was directly proportional to aqueous flow rate, in agreement with the steady-flow model. However, contrary to the steady-flow model, PPR showed inverse dependence on iris-lens canal width and predicted the anticipated PC-AC pressure gradient changes at simulated light-dark transition in eyes of patients with clinically narrow angles and ultrasound biomicroscopy evidenced pupillary block. CONCLUSIONS: Upon the incorporation of real ultrasound biomicroscopy measurements in numerical experimentations with both models, the present pulsatile-flow model, contrary to the steady-flow model, showed good predictability of PC-AC pressure gradient changes in a typical condition predisposing to pupillary block.

Anterior Chamber↗