PubMed Health⌕ Search

Biomedical subjects

Kathryn G Klemic

Publications and source records attributed to Kathryn G Klemic.

5 recordsLinked to original sources

Microfluidic system for planar patch clamp electrode arrays.

We present a microfluidic system integrated with disposable cell interface partitions for simultaneous patch clamp recordings. Glass-supported poly(dimethylsiloxane) (PDMS) partitions, having a 2 microm air-blown aperture, were reversibly sealed to a microfluidic system including PDMS channels with isolation valves and microfabricated Ag/AgCl electrodes. Gigaseal recordings from RBL-1 cells were obtained with a 24% success rate. Simultaneous whole cell recordings from valve-isolated electrodes were obtained.

Animals↗

Microchip technology in ion-channel research.

The electrical activity of living cells can be monitored in various ways, but for the study of ion channels and the drugs that affect them, the patch-clamp techniques are the most sensitive. Recent developments in microfabricated patch-clamp electrodes are reviewed, and technical challenges for the future are discussed.

Action Potentials↗

An air-molding technique for fabricating PDMS planar patch-clamp electrodes.

We present a new technique for fabricating planar patch electrodes in the laboratory. Planar electrodes are micromolded using a micron-sized stream of air to define an aperture in the silicone elastomer, polydimethylsiloxane (PDMS). We have previously demonstrated that planar PDMS electrodes make excellent patch electrodes after surface modification. We demonstrate single-channel measurements of the rSlo channel in Xenopus oocytes and whole-cell measurements in CHO and RBL mammalian cell lines, using planar PDMS electrodes.

Air↗

Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells.

The patch clamp method measures membrane currents at very high resolution when a high-resistance 'gigaseal' is established between the glass microelectrode and the cell membrane (Pflugers Arch. 391 (1981) 85; Neuron 8 (1992) 605). Here we describe the first use of the silicone elastomer, poly(dimethylsiloxane) (PDMS), for patch clamp electrodes. PDMS is an attractive material for patch clamp recordings. It has low dielectric loss and can be micromolded (Annu. Rev. Mat. Sci. 28 (1998) 153) into a shape that mimics the tip of the glass micropipette. Also, the surface chemistry of PDMS may be altered to mimic the hydrophilic nature of glass (J. Appl. Polym. Sci. 14 (1970) 2499; Annu. Rev. Mat. Sci. 28 (1998) 153), thereby allowing a high-resistance seal to a cell membrane. We present a planar electrode geometry consisting of a PDMS partition with a small aperture sealed between electrode and bath chambers. We demonstrate that a planar PDMS patch electrode, after oxidation of the elastomeric surface, permits patch clamp recording on Xenopus oocytes. Our results indicate the potential for high-throughput patch clamp recording with a planar array of PDMS electrodes.

Coated Materials, Biocompatible↗