PubMed Health⌕ Search

Biomedical subjects

Katsuaki Inoue

Publications and source records attributed to Katsuaki Inoue.

10 recordsLinked to original sources

X-ray microdiffraction and conventional diffraction from frozen-hydrated biological specimens.

A system for recording microdiffraction patterns from micrometer-sized quick-frozen hydrated biological specimens at the high-flux beamline BL40XU of SPring-8 is described. The optics consists of a pair of pinholes drilled into tantalum substratum, with a defining aperture of diameter 2 microm. The frozen specimens are placed in an in-vacuum cryochamber mounted on a three-axis goniometer, where the specimens are stably held at a liquid-nitrogen temperature ( approximately 74 K). A beam size of 1.5 microm (full width at half-maximum) is attained at the sample position. By using this system, diffraction patterns have been recorded from an isolated single myofibril (diameter approximately 3 microm) of an insect flight muscle in an area equivalent to a single sarcomere (length approximately 3 microm). The technique is potentially applicable to other micrometer-sized hydrated biological specimens, which are more susceptible to radiation damage than dry synthetic polymers or biopolymers. The quick-freezing of biological specimens has also been proven useful in reducing the specimen volume in the beam in conventional diffraction recordings.

Animals↗

Structural changes of actin-bound myosin heads after a quick length change in frog skeletal muscle.

Changes in the x-ray diffraction pattern from a frog skeletal muscle were recorded after a quick release or stretch, which was completed within one millisecond, at a time resolution of 0.53 ms using the high-flux beamline at the SPring-8 third-generation synchrotron radiation facility. Reversibility of the effects of the length changes was checked by quickly restoring the muscle length. Intensities of seven reflections were measured. A large, instantaneous intensity drop of a layer line at an axial spacing of 1/10.3 nm(-1) after a quick release and stretch, and its partial recovery by reversal of the length change, indicate a conformational change of myosin heads that are attached to actin. Intensity changes on the 14.5-nm myosin layer line suggest that the attached heads alter their radial mass distribution upon filament sliding. Intensity changes of the myosin reflections at 1/21.5 and 1/7.2 nm(-1) are not readily explained by a simple axial swing of cross-bridges. Intensity changes of the actin-based layer lines at 1/36 and 1/5.9 nm(-1) are not explained by it either, suggesting a structural change in actin molecules.

Actins↗

Light-induced global structural changes in phytochrome A regulating photomorphogenesis in plants.

Phytochromes are photoreceptor proteins that monitor the light environment and regulate a variety of photomorphogenic responses to optimize the growth and development of plants. Phytochromes comprise N-terminal photosensory and C-terminal regulatory domains. They are mutually photoconvertible between a red-light-absorbing (Pr) and a far-red-light-absorbing (Pfr) form. Their interconversion by light stimuli initiates downstream signaling cascades. Here we report the molecular structures of pea phytochrome A lacking the N-terminal 52 amino-acid residues in the Pr and Pfr forms studied by small-angle X-ray scattering. A new purification protocol yielded monodispersive sample solutions. The molecular mass and the maximum dimension of Pr determined from scattering data indicated its dimeric association. The molecular structure of Pr predicted by applying the ab initio simulation method to the scattering profile was approximated as a stack of two flat bodies, comprising two lobes assignable to the functional regions. Scattering profiles recorded under red-light irradiation showed small but definite changes from those of Pr. The molecular dimensions and predicted molecular structure of Pfr suggest global structural changes such as movement of the C-terminal domains in the Pr-to-Pfr phototransformation. Red-light-induced structural changes in Pfr were reversible, mostly due to thermal relaxation processes.

Light↗

Structural stability of oligomeric chaperonin 10: the role of two beta-strands at the N and C termini in structural stabilization.

Chaperonin 10 (cpn10) is a well-conserved subgroup of the molecular chaperone family. GroES, the cpn10 from Escherichia coli, is composed of seven 10kDa subunits, which form a dome-like oligomeric ring structure. From our previous studies, it was found that GroES unfolded completely through a three-state unfolding mechanism involving a partly folded monomer and that this reaction was reversible. In order to study whether these unfolding-refolding characteristics were conserved in other cpn10 proteins, we have examined the structural stabilities of cpn10s from rat mitochondria (RatES) and from hyperthermophilic eubacteria Thermotoga maritima (TmaES), and compared the values to those of GroES. From size-exclusion chromatography experiments in the presence of various concentrations of Gdn-HCl at 25 degrees C, both cpn10s showed unfolding-refolding characteristics similar to those of GroES, i.e. two-stage unfolding reactions that include formation of a partially folded monomer. Although the partially folded monomer of TmaES was considerably more stable compared to GroES and RatES, it was found that the overall stabilities of all three cpn10s were achieved significantly by inter-subunit interactions. We studied this contribution of inter-subunit interactions to overall stability in the GroES heptamer by introducing a mutation that perturbed subunit association, specifically the interaction between the two anti-parallel beta-strands at the N and C termini of this protein. From analyses of the mutants' stabilities, it was revealed that the anti-parallel beta-strands at the subunit interface are crucial for subunit association and stabilization of the heptameric GroES protein.

Amino Acid Sequence↗

Structural transition of bacteriorhodopsin is preceded by deprotonation of Schiff base: microsecond time-resolved x-ray diffraction study of purple membrane.

The structural changes in the photoreaction cycle of bacteriorhodopsin, a light-driven proton pump, was investigated at a resolution of 7 angstroms by a time-resolved x-ray diffraction experiment utilizing synchrotron x rays from an undulator of SPring-8. The x-ray diffraction measurement system, used in coupling with a pulsed YAG laser, enabled us to record a diffraction pattern from purple membrane film at a time-resolution of 6 micros over the time domain of 5 micros to 500 ms. In the time domain, the functionally most important M-intermediate appears. A series of time-resolved x-ray diffraction data after photo-excitation showed clear intensity changes caused by the conformational changes of helix G in the M-intermediate. The population of the reaction intermediate was prominently observed at approximately 5 ms after a photo-stimulus. In contrast, absorption measurement indicated the deprotonation of the Schiff base predominantly occurred at approximately 300 micros after a photo-stimulus. These results showed that the conformational changes characterizing structurally the M-intermediate predominantly occur at a later stage of the deprotonation of the Schiff base. Thus, the M-intermediate can be divided into two metastable stages with different physical characteristics.

Bacteriorhodopsins↗

CCD-based X-ray area detector for time-resolved diffraction experiments.

A fast X-ray area detector for diffraction, scattering and imaging experiments at microsecond to millisecond time resolution has been developed. The key element of the detector is a fast (291 frames s(-1)) framing camera with three CCDs. A prism forms identical images on the CCDs and the frame rate is increased three times by reading them alternately. In order to convert X-rays into visible light that is detectable with the CCDs, an X-ray image intensifier is used. The camera can also be used with a high-resolution X-ray detector. In both cases it was found to be important to use a phosphor with a short decay time to fully make use of the high-speed framing capability of the camera. Preliminary results of a fibre diffraction experiment on a skeletal muscle and coronary angiography are presented.

Animals↗

Hierarchical map of protein unfolding and refolding at thermal equilibrium revealed by wide-angle X-ray scattering.

Hierarchical features of the thermal unfolding-refolding structural transition of hen egg white lysozyme (HEWL) have been studied in the temperature range from 13 to 84 degrees C by using high-resolution wide-angle X-ray scattering (WAXS) measurements at a third-generation synchrotron source. We have gathered high-statistic WAXS data of the reversible unfolding-refolding process of HEWL in the q range from approximately 0.05 to approximately 3 A(-1) [q = (4pi/lambda) sin(theta/2), where theta is the scattering angle and lambda the wavelength]. This measured q range corresponds to the spatial distance from approximately 2 to approximately 125 A, which covers all hierarchical structures of a small globular protein such as HEWL, namely, tertiary, domain, and secondary structures. Because of this, we have found that the pH dependence of the thermal structural transition of HEWL is well characterized by the various hierarchical levels and the transition concurrence among them. In this report, we present a new hierarchical map depiction of unfolding-refolding transitions. Using scattering with various ranges of q values, we determine the molar ratio of native-like protein structure defined by the data in each range, thus producing a map of the amount of native-like structure as a function of the hierarchical level or resolution. This map can visualize a detailed feature of the unfolding-refolding transition of a protein depending on various structural hierarchical levels; however, the exact meaning of the map will await sharpening by additional works.

Animals↗

A large-area CMOS imager as an X-ray detector for synchrotron radiation experiments.

The performance of a CMOS flatpanel imager from Hamamatsu Photonics (C7942) has been tested in various synchrotron radiation experiments. This detector has a detection area of about 120 mm x 120 mm with 0.05 mm pixels, and a frame rate of 2 s(-1). The commercially available product was insensitive to X-rays with an energy lower than 15 keV, but slight modifications solved this problem. Images obtained in small-angle scattering, protein crystallography and medical imaging experiments were all of high quality. The fast readout and the large area are advantageous in real-time imaging. Although its noise level is higher than the area detectors that are currently used in synchrotron radiation experiments, it is particularly useful in experiments where other bulky detectors cannot be used. Its relatively low price (about 30,000 US dollars) makes it a unique option in the choice of detectors.

Animals↗

Wavelength-dispersive total-reflection X-ray fluorescence with an efficient Johansson spectrometer and an undulator X-ray source: detection of 10-16 g-level trace metals.

The present paper reports significant enhancement of the detection power for total-reflection X-ray fluorescence (TXRF). The employment of an efficient wavelength-dispersive spectrometer rather than a conventional Si(Li) detector, as well as the use of a quasi-monochromatic undulator X-ray source, completely changed the quality of X-ray florescence spectra. The energy resolution is 20 times better, which effectively contributes to reducing the low-energy tail of the scattering background and to separating neighboring X-ray florescence peaks. Another advantage is its capability with respect to high-counting-rate measurements, which ensure the detection of weak signals from trace materials. The absolute and relative detection limit for nickel are 3.1 x 10(-16) g and 3.1 ppt (pg/g) for a 0.1-microL droplet of pure water, respectively, which is nearly 50 times better than the current best data achieved by conventional energy-dispersive TXRF using a Si(Li) detector system.

Equipment Design↗

Structural hierarchy of several proteins observed by wide-angle solution scattering.

In the present study using a high-intensity X-ray beam from a third-generation synchrotron radiation source, it is demonstrated that a wide-angle X-ray scattering (WAXS) profile from several globular proteins in solution can reflect not only the overall structures (approximately 300 A distance resolution) but also intramolecular structures ranging to secondary structures (approximately 2.5 A distance resolution). The proteins treated in the present experiments are classified as different types of structure categories, namely, as all-alpha, all-beta and alpha + beta proteins. Here the full-range experimental scattering curves are compared with the theoretical curves, suggesting a further availability of the SR-WAXS method for studies of structure hierarchy and the function of proteins in solutions.

Animals↗