PubMed Health⌕ Search

Biomedical subjects

Katsutoshi Murata

Publications and source records attributed to Katsutoshi Murata.

2 recordsLinked to original sources

Distinguishing between anterior cerebral artery and middle cerebral artery perfusion by color-coded perfusion direction mapping with arterial spin labeling.

The purpose of this study was to evaluate collateral circulation by describing anterior cerebral artery and middle cerebral artery perfusion areas. Pairs of image sets spin labeled on the medial and lateral side were used. A pixel-by-pixel t test was performed, with blue gradation used to display lateral perfusion (ie, middle cerebral artery) and orange gradation for anterior cerebral artery perfusion. Extensions of anterior cerebral artery perfusion areas in cases of middle cerebral artery stenosis were described. This method may aid in estimation of collateral circulation for stroke treatment.

Cerebral Angiography↗

[Basic examination of in-plane spatial resolution in multi-slice CT].

In computed tomography(single-slice spiral CT, conventional CT), in-plane(x-y plane) spatial resolution is consistently identified as depending on the detector density of the in-plane(x-y plane). However, we considered that the in-plane(x-y plane) spatial resolution of multi-slice CT (MSCT) was influenced by an error in the detector's sensitivity to the Z-axis and by the frequency of use of direct row data and complementary row data when the image of spiral pitches(SP) was reconstructed. Our goal in this experiment was to analyze the relationship of the in-plane(x-y plane)spatial resolution of an asymmetric-type detector in MSCT to SP, tube current, and rotation time. By employing a tungsten wire phantom of 0.2 mm in diameter, we examined modulation transfer functions(MTF) by point-spread functions(PSF) of CT-images. Next, using the mean-square-root bandwidth theory, we analyzed the MTF of wire phantoms. The analysis of in-plane(x-y plane) spatial resolution revealed that various tube currents had no effect on the value of the mean-square-root bandwidth. However, rotation time and high spiral pitch did have an effect on mean-square-root bandwidth. Considering the results mentioned above, spiral pitch(z-axis reconstruction algorithm) had a slight effect on in-plane(x-y plane) spatial resolution of asymmetric-type detectors in MSCT. Accordingly, we proposed a new general view of VDDz(view/mm) in MSCT that considered view data density on the Z-axis according to spiral pitch(mm/rotation), rotation time(view/rotation), and slice collimation.

Tomography, Spiral Computed↗