PubMed Health⌕ Search

PubMed · 12469031

[Basic examination of in-plane spatial resolution in multi-slice CT].

Abstract

In computed tomography(single-slice spiral CT, conventional CT), in-plane(x-y plane) spatial resolution is consistently identified as depending on the detector density of the in-plane(x-y plane). However, we considered that the in-plane(x-y plane) spatial resolution of multi-slice CT (MSCT) was influenced by an error in the detector's sensitivity to the Z-axis and by the frequency of use of direct row data and complementary row data when the image of spiral pitches(SP) was reconstructed. Our goal in this experiment was to analyze the relationship of the in-plane(x-y plane)spatial resolution of an asymmetric-type detector in MSCT to SP, tube current, and rotation time. By employing a tungsten wire phantom of 0.2 mm in diameter, we examined modulation transfer functions(MTF) by point-spread functions(PSF) of CT-images. Next, using the mean-square-root bandwidth theory, we analyzed the MTF of wire phantoms. The analysis of in-plane(x-y plane) spatial resolution revealed that various tube currents had no effect on the value of the mean-square-root bandwidth. However, rotation time and high spiral pitch did have an effect on mean-square-root bandwidth. Considering the results mentioned above, spiral pitch(z-axis reconstruction algorithm) had a slight effect on in-plane(x-y plane) spatial resolution of asymmetric-type detectors in MSCT. Accordingly, we proposed a new general view of VDDz(view/mm) in MSCT that considered view data density on the Z-axis according to spiral pitch(mm/rotation), rotation time(view/rotation), and slice collimation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Takanori Hara, Hideki Kato, Mitsutoshi Akiyama, Katsutoshi Murata. 2002. [Basic examination of in-plane spatial resolution in multi-slice CT].. https://doi.org/10.6009/jjrt.kj00001364383

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Multi-slice spiral CT: recent advances of technology and clinical application].

Multi-slice spiral CT has been an outstanding progress in developmental history of CT technology. The technical indexes of all three respects, ie scanning range time and spatial resolution are all marked improved. And several robust post-processing techniques have been imported into CT data post-scanning reconstruction, which help massive volume data being sufficiently and optimally interpreted. Therefore, newer advances have been achieved both in clinical applications and diagnostic efficacy.

Tomography, Spiral Computed↗

[Report on the 89th Scientific Assembly and Annual Meeting of the Radiological Society of North America--evaluation of spatial resolution and contrast resolution for MPR diagnosis].

PURPOSE: The advent of the helical scanner and the multi-slice helical scanner has encouraged image diagnosis using MPR display. In this study we investigated methods of evaluating spatial and contrast resolution when using MPR image display. METHOD AND MATERIALS: Using a three-dimensional ladder phantom to evaluate spatial resolution, we placed ladders along the MPR sections and measured the responses in the CT values. For evaluating contrast resolution, we used a phantom involving subtle differences in the CT values. We then found the CNR of those CT image. RESULTS: The results of the experiment showed that when the FOV value, collimation and helical pitch were set at 240 mm, 0.5 mm, 3 and 320 mm, 1.0 mm, 3 respectively, good MPR display were achieved with respect to both spatial resolution and contrast resolution. CONCLUSION: Image diagnosis using MPR display is an extremely useful method of diagnosis from an anatomical perspective. We were able to get better understanding through this investigation of the scanning parameter that optimizes time resolution and contrast resolution when using MPR display. LO: The advent of the helical scanner and the multi-slice helical scanner has encouraged image diagnosis using MPR display. In this study we investigated methods of evaluating spatial and contrast resolution when using MPR image display.

Tomography, Spiral Computed↗