PubMed Health⌕ Search

Biomedical subjects

Kazuo Hosokawa

Publications and source records attributed to Kazuo Hosokawa.

13 recordsLinked to original sources

Colorimetric biosensors based on DNA-nanoparticle conjugates.

In this review, we present an overview of the technologies in colorimetric biosensors based on DNA-nanoparticle conjugates. Two types of DNA-nanoparticles aggregation assays are summarized. One of the methods relies on cross-linking of the gold nanoparticle (GNP) by hybridization. The crosslinking system was used not only to detect target DNA sequences, but also to detect metal ions or small molecules which were recognized by DNAzymes. The other method is the GNP non-crosslinking system. This approach shows high performance in the detection of single nucleotide polymorphisms. These methods do not need special equipment and open up a new possibility of point-of-care diagnoses.

Biosensing Techniques↗

Detection of single-base mismatch at distal end of DNA duplex by electrochemical impedance spectroscopy.

Herein, we report an anomalous electrochemical behavior of surface-bound DNA duplex that has single-base mismatches at its distal end. Single-stranded 15-base DNA was immobilized at its 5'end onto gold electrode surfaces. After hybridization with complementary or mismatched DNA, electrochemical impedance spectra were obtained using [Fe(CN)(6)]3-/4- as redox marker ions. Hybridization with the complementary DNA reduced the charge-transfer resistance (R(CT)), whereas single-base mismatches at the distal end of the duplex largely increased the R(CT). This anomaly was found only with the distal end: the increase in R(CT) was not observed for mismatches at either the middle or the proximal end. These results indicate that electrochemical detection of single-base alterations at an end of sample DNA is exceptionally easy because of the diametrically opposite responses. This detection principle is promising for the typing of single-nucleotide polymorphisms in combination with the single-base primer extension protocol.

Base Pair Mismatch↗

Surface plasmon resonance imaging on a microchip for detection of DNA-modified gold nanoparticles deposited onto the surface in a non-cross-linking configuration.

Recently we reported that gold nanoparticles (GNPs) with fully matched duplexes on their surfaces are selectively deposited onto walls of poly(dimethylsiloxane) (PDMS) microchannels at high salt concentrations. In this study, the surface plasmon resonance (SPR) imaging technique was applied to monitor this phenomenon for improvement of detection sensitivity and elucidation of the phenomenon. The microchip was fabricated by bonding a surface-patterned PDMS plate and a gold thin film-deposited glass substrate. Probe oligonucleotide-modified GNPs were hybridized with target oligonucleotides to make fully matched or single-base-mismatched duplexes. The hybridized GNP solution was mixed with an NaCl solution in a Y-shaped microchannel. The deposition of the GNPs onto the gold sensor surface was detected by SPR imaging. Discrimination of the targets was possible with limit of detection of 32 nM (19 fmol) without temperature control in 5 min. Detailed analysis indicated that a seed layer of GNPs was initially adsorbed onto the sensor surface regardless of the target sequence. Therefore, in combination with a portable SPR device, the proposed method is promising for point-of-care testing of single-nucleotide polymorphsims.

DNA↗

Power-free sequential injection for microchip immunoassay toward point-of-care testing.

This paper presents a simple fluid handling technique for microchip immunoassay. Necessary solutions were sequentially injected into a microchannel by air-evacuated poly(dimethylsiloxane), and were passively regulated by capillary force at the inlet opening. For heterogeneous immunoassay, microchips are potentially useful for reduction of sample consumption and assay time. However, most of the previously reported microchips have limitations in their use because of the needs for external power sources for fluid handling. In this paper, an on-chip heterogeneous immunofluorescence assay without such an external power source is demonstrated. The microchip consisting of poly(dimethylsiloxane) (PDMS) and glass has a simple structure, and therefore is suitable for single-use applications. Necessary solutions were sequentially injected into a microchannel in an autonomous fashion with the power-free pumping technique, which exploits the high solubility and the rapid diffusion of air in PDMS. For deionized water, this method yielded flow rates of 3-5 nL s-1 with reproducibility of 4-10%. The inlet opening of the microchannel functioned as a passive valve to hold the solution when the flow was finished. Rabbit immunoglobulin G (rIgG) and human C-reactive protein (CRP) were detected using the microchannel walls as reaction sites. With the sample consumption of 1 microL and the assay time of approximately 20 min including the antibody immobilization step, the sandwich immunoassay methods for rIgG and CRP exhibited the limits of detection of 0.21 nM (0.21 fmol) and 0.42 nM (0.42 fmol), respectively.

Animals↗

Affinity capillary electrophoresis of DNA for detection of single-nucleotide polymorphisms and point mutations. Comprehensive study for optimization of the weak affinity.

A single-stranded DNA and its point mutant can be separated with affinity capillary electrophoresis (ACE) in which an appropriate ligand DNA is used as a pseudo-stationary affinity phase. In this paper, we systematically examine the effects of ligand sequence, capillary temperature, and cation concentration on the ACE separation quality, which is quantitatively evaluated in terms of resolution and peak height. For fine tuning of the affinity, control of MgCl(2) concentration and insertion of a spacer sequence into the ligand DNA are more effective than control of the capillary temperature. For design of the ligand DNA, a simple strategy is proposed, based on the prediction of melting temperature. This strategy was tested with eleven different sample sequences. All of them were separated under the same conditions (250 microM MgCl(2) and 25 degrees C), and nine cases of them had satisfactory separation qualities.

Cations↗

Autonomous polymer loading and sample injection for microchip electrophoresis.

We have developed an extremely simple method for microchip electrophoresis. Loading of a sieving polymer solution and injection of a sample solution are autonomously executed by a microchip fabricated in poly(dimethylsiloxane) (PDMS). In advance, the energy for the fluid pumping is stored in bulk PDMS by evacuating air dissolved in PDMS, and the information for the sample plug regulation is coded into the microchannel design. Besides the simplicity, our method brings about an advantageous effect: sample compaction due to the discontinuous electrophoretic mobility at the sample/polymer interface. The sample compaction effect was moderate in ordinary size-dependent separation for double-stranded DNA and was extreme in affinity electrophoresis for single-stranded DNA (ssDNA). In the latter separation mode, ssDNA components were sequence-specifically separated by difference in affinity to a probe oligonucleotide immobilized to the sieving polymer matrix. We separated up to 60-mer ssDNA mixtures based on single-base substitutions. The separation processes included typically 100-fold sample compaction and were completed within 15-30 s. This technology provides easy, simple, and sensitive method for detection of gene point mutations and typing of single-nucleotide polymorphisms.

Base Sequence↗

Non-cross-linking gold nanoparticle aggregation as a detection method for single-base substitutions.

Aggregation of DNA-modified gold nanoparticles in a non-cross-linking configuration has extraordinary selectivity against terminal mismatch of the surface-bound duplex. In this paper, we demonstrate the utility of this selectivity for detection of single-base substitutions. The samples were prepared through standard protocols: DNA extraction, PCR amplification and single-base primer extension. Oligonucleotide-modified nanoparticles correctly responded to the unpurified products from the primer extension: aggregation for the full match and dispersion for all the mismatches. Applicability of this method to genomic DNA was tested with five human tumor cell lines, and verified by conventional technologies: mass spectrometry and direct sequencing. Unlike the existing methods for single-base substitution analysis, this method does not need specialized equipments, and opens up a new possibility of point-of-care diagnosis for single-nucleotide polymorphisms.

Biosensing Techniques↗

Detection of single-base mutation by affinity capillary electrophoresis using a DNA-polyacrylamide conjugate.

We have developed an affinity capillary electrophoresis (ACE) method for detection of gene point mutations using a DNA-polyacrylamide conjugate as a pseudostationary affinity phase. In this study, the target DNA was prepared by mixing two PCR products: the wild type of K-ras gene and its codon 12 point mutant. The ligand DNA was designed to be complementary to codons 11 and 12 of the wild type. The target DNA was denatured by the addition of formamide and by heating at 95 degrees C for 5 min, and then electrophoretically separated by difference in affinity to the pseudoimmobilized ligand DNA. The method successfully separated a mixture of the wild-type DNA and each of six codon 12 point mutants by the same ligand DNA. The limit of mutation detection was determined by mixing the wild-type DNA with decreasing concentrations of the mutant DNA. The lowest level of detection was 10% mutant DNA in a background of the wild type. The practicability of this method has been confirmed using a colorectal carcinoma cell line. This study is the first demonstration of detection of gene point mutation in polymerase chain reaction (PCR) products using ACE, and opens up a new possibility of CE-based gene diagnosis.

Acrylic Resins↗

Interface motion of capillary-driven flow in rectangular microchannel.

In microchannel flow, gas-liquid interface behavior is important for developing a wide range of microfluidic applications, especially in passive microfluidic systems. This paper presents a discussion of interface motion driven by capillary action in a microchannel. We have extended the theory beyond the previous theory of capillary rise problem for a circular tube, to a rectangular microchannel. The same formula for the relation between nondimensional time and interface position is obtained as for a circular tube. We examined rectangular microchannels with several sizes (about 50 to 100 microm square) of glass capillaries and 85 x 68 microm and 75 x 45 microm polydimethylsiloxane (PDMS) microchannels fabricated by photolithography technique, respectively. We observed movement of the gas-liquid interface position and compared it to the dimensionless relation. We obtained the value of a dimensionless variable of driving force that is related to dynamic contact angles for glass-water, glass-ethanol, and PDMS-ethanol. Using this variable, interface motion can be predicted for any size of rectangular channels.

Journal Article↗

Power-free poly(dimethylsiloxane) microfluidic devices for gold nanoparticle-based DNA analysis.

An extremely simple, power-free pumping method for poly(dimethylsiloxane)(PDMS) microfluidic devices is presented. By exploiting the high gas solubility of PDMS, the energy for the pumping is pre-stored in the degassed bulk PDMS, therefore no additional structures other than channels and reservoirs are required. In a Y-shaped microchannel with cross section of 100 microm width x 25 microm height, this method has provided flow rate of 0.5-2 nL s(-1), corresponding to linear velocity of 0.2-0.8 mm s(-1), with good reproducibility. As an application of the power-free pumping, gold nanoparticle-based DNA analysis, which does not rely on the cross-linking mechanism between nanoparticles, has been implemented in a microchannel with three inlets. Target 15mer DNA has been easily and unambiguously discriminated from its single-base substituted mutant. Instead of colorimetric detection in a conventional microtube, an alternative detection technique suitable for microdevices has been discovered-observation of deposition on the PDMS surfaces. The channel layout enabled two simultaneous DNA analyses at the two interfaces between the three laminar streams.

DNA↗

Single-base mutation detection using neutravidin-modified polystyrene nanoparticle aggregation.

A single-base mutation assay using the non-crosslinking aggregation of neutravidin-modified polystyrene nanoparticles is described. This method requires only two steps: hybridization of biotinylated probe and sample DNAs, and then mixing with neutravidin-modified nanoparticles. The aggregation was detected within 20 min in total. A combination of the DNA non-crosslinking aggregation and biotin-avidin technology has allowed sufficient performance for the detection of single nucleotide polymorphisms.

Avidin↗

Rapid aggregation of gold nanoparticles induced by non-cross-linking DNA hybridization.

To date, aggregation of DNA-functionalized gold nanoparticles by hybridization of target DNA in a cross-linking configuration has been intensively studied. Here, we report that aggregation in a non-cross-linking configuration is also possible and is even better from the viewpoint of genetic analysis because of its speed and sensitivity. In this system, 15 nm diameter gold nanoparticles functionalized with (alkanethiol)-15mer DNA are hybridized to target 15mer DNA at room temperature. At high NaCl concentration (>/=0.5 M), hybridization with complementary target DNA induces nanoparticle aggregation based on the salting-out effect. The aggregation can be detected by a colorimetric change of the colloidal solution within 3 min. Furthermore, unusual sensitivity of this system for single-base mismatch at the terminus opposite to the anchored side has been discovered. In fact, target DNA with such a kind of mismatch does not induce the colorimetric change at all, while target DNA with single-base mismatch at the middle of it cannot be discriminated from the fully complementary target. This non-cross-linking aggregation system opens up a new possibility of rapid and reliable genetic analysis.

Acrylic Resins↗