PubMed Health⌕ Search

PubMed · 15228105

Single-base mutation detection using neutravidin-modified polystyrene nanoparticle aggregation.

Abstract

A single-base mutation assay using the non-crosslinking aggregation of neutravidin-modified polystyrene nanoparticles is described. This method requires only two steps: hybridization of biotinylated probe and sample DNAs, and then mixing with neutravidin-modified nanoparticles. The aggregation was detected within 20 min in total. A combination of the DNA non-crosslinking aggregation and biotin-avidin technology has allowed sufficient performance for the detection of single nucleotide polymorphisms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kae Sato, Munetaka Sawayanagi, Kazuo Hosokawa, Mizuo Maeda. 2004. Single-base mutation detection using neutravidin-modified polystyrene nanoparticle aggregation.. https://doi.org/10.2116/analsci.20.893

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Avidin plate assay system for enzymatic characterization of a histone lysine methyltransferase.

Modification of proteins by protein methyltransferases has several important biological functions. Here, we study the methylation of histone H3 tail at position Lys9 by the Dim-5 histone lysine methyltransferase, which is involved in epigenetic signaling and gene silencing and which triggers DNA methylation in Neurospora crassa. We have developed a new assay to detect protein methylation using a biotinylated synthetic peptide substrate and a radioactively labeled coenzyme. We show that the assay is linear with respect to time and enzyme concentration (under multiple turnover conditions) and that its background is very low. Data points were reproducible within 3%. At least 200 pmol of biotinylated peptide is bound completely to the microplate. We employed the assay system to determine the K(m) and k(cat) values of the Dim-5 enzyme for the methylation of a 20 mer peptide to be 7.4 microM and 2.3 min(-1), respectively. In addition, we determined the activity of four Dim-5 variants, ranging from full activity to less than 1% of residual activity. The microplate biotin/avidin peptide methylation assay developed here is convenient, very accurate, reproducible, and inexpensive. Because it yields quantitative results, it can be employed for a characterization of the enzymatic properties of histone lysine methyltransferases and other protein methyltransferases. The assay also is well suited for high-throughput applications.

Avidin↗

A new chemically amplified electrochemical system for the detection of biological affinity reactions: direct and competitive biotin assay.

Quantitation of biological affinity reactions by a newly developed chemically amplified electrochemical detection method was demonstrated with the biotin-avidin binding pair. In the method, ruthenium tris(2,2'-bipyridine)(Ru-bipy) was used as an electrochemical signal-generating tag. Its oxidation current on an indium tin oxide (ITO) electrode was amplified with a sacrificial electron donor, oxalate. Because oxalate itself produced negligible current on the electrode, the signal-to-background ratio was greatly enhanced in comparison with other chemical amplification systems. Although the Ru-bipy/oxalate redox couple has been employed previously in electrochemiluminescent and photoelectrochemical detection, its use in a catalytic amperometric detection of biological binding assays has not been reported. To implement the method in the detection of biotin-avidin recognition, avidin was immobilized on an ITO electrode, and was reacted with biotin in solution. Immobilization of avidin by passive adsorption was found to be relatively stable under the condition of the affinity reaction. In the direct assay, biotin labelled with Ru-bipy was recognized by avidin and accumulated on the electrode surface, which was then detected electrochemically in the presence of oxalate. A linear relationship between electrochemical current and biotin concentration was obtained in the range of 1-300 ng mL(-1). In the competitive assay, a mixed solution of unlabelled biotin (the analyte) of various concentrations and 100 ng mL(-1) labelled biotin was reacted with avidin on the surface. As the concentration of the unlabelled biotin increased, less labelled biotin bound to avidin, leading to a reduction in the electro-catalytical response of Ru-bipy. A detection limit of 1 ng mL(-1) biotin was obtained in the competitive assay, which is close to the sensitivity of some enzyme-labelled amperometric assays.

Avidin↗