PubMed Health⌕ Search

Biomedical subjects

Kazuo Noma

Publications and source records attributed to Kazuo Noma.

3 recordsLinked to original sources

[Examination of attenuation correction using low-dose computed tomography].

Attenuation correction is necessary for the reconstruction of SPECT images. One report has mentioned that attenuation correction by X-ray computed tomography (CT) is effective for a non-uniform attenuation body. We examined the effect of attenuation correction on SPECT images by changing the scanning conditions of CT, and evaluated the possibility of attenuation correction by low-dose CT. The phantom was scanned under several X-ray tube conditions varying from 80 kV to 135 kV and from 7.5 mAs to 200 mAs. We obtained equations of attenuation correction based on the Hounsfield Unit (HU) units of each pixel and compared the effects of attenuation correction. The results showed that the equation for attenuation correction under each condition did not vary significantly, and the effects of attenuation correction by the equations did not vary significantly between CT of low dose and that of clinical dose. This result suggest that the attenuation correction obtained by low-dose CT was equal to that obtained by the clinical dose. In conclusion, it seemed that the equation and map of attenuation correction matched with each radionuclide yielded more adequate attenuation correction than conventional methods.

Image Processing, Computer-Assisted↗

The first trial of phase contrast imaging for digital full-field mammography using a practical molybdenum x-ray tube.

RATIONALE AND OBJECTIVES: The image quality of a newly developed full-field digital phase contrast mammography (PCM) system and of a conventional screen-film (SF) mammography system were compared via images of a phantom and receiver operating characteristic (ROC) analysis of clinical images. METHODS: Magnified (1.75X) PCM images were scanned (sampling rate, 43.75 microm) and then reduced to original-sized, 25-micron pixel images printed on photothermographic film. Along with corresponding SF images, the phantom images were evaluated subjectively, and the clinical images of 38 patients were subjected to ROC analysis of mass and microcalcification. RESULTS: In the image quality of a phantom, the PCM exceeded the SF. In both mass and microcalcification, the ROC analysis Az values of the PCM clinical images surpassed those of the SF images. CONCLUSION: The PCM provides better images than the SF. Clinical trials suggest superior detection of both mass and microcalcification by full-field digital PCM over conventional SF mammography.

Breast Diseases↗

[Introduction of manual for the management radioactive medical waste].

Societies concerned with radioactive rays and nuclear medicine have recently highlighted the necessity of managing radioactive medical waste resulting from nuclear medicine examinations. We introduce a manual that we have created and explain its use in decision-making and management practices aimed at the reduction of radioactive medical waste at hospitals that have not yet solved this problem. We hope that our manual will help in reducing this medical waste.

Japan↗