[Examination of attenuation correction using low-dose computed tomography].

Abstract

Attenuation correction is necessary for the reconstruction of SPECT images. One report has mentioned that attenuation correction by X-ray computed tomography (CT) is effective for a non-uniform attenuation body. We examined the effect of attenuation correction on SPECT images by changing the scanning conditions of CT, and evaluated the possibility of attenuation correction by low-dose CT. The phantom was scanned under several X-ray tube conditions varying from 80 kV to 135 kV and from 7.5 mAs to 200 mAs. We obtained equations of attenuation correction based on the Hounsfield Unit (HU) units of each pixel and compared the effects of attenuation correction. The results showed that the equation for attenuation correction under each condition did not vary significantly, and the effects of attenuation correction by the equations did not vary significantly between CT of low dose and that of clinical dose. This result suggest that the attenuation correction obtained by low-dose CT was equal to that obtained by the clinical dose. In conclusion, it seemed that the equation and map of attenuation correction matched with each radionuclide yielded more adequate attenuation correction than conventional methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Harumi Iguchi, Tetsuo Kida, Kazuo Noma, Masahiro Yoshimura, Masanari Hamazu, Kazutaka Masuda. 2006-06-20. [Examination of attenuation correction using low-dose computed tomography].. https://doi.org/10.6009/jjrt.62.840

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rapid and accurate measurement for phase-change optical recording bits.

Conducting atomic force microscopy (CAFM) and scanning surface potential microscopy (SSPM) have been used to image the phase-change optical recording bits. Commercially available digital versatile discs (DVD) + rewritable (RW) with initialization process were measured in experiments. Comparing the measurement results of both, the measurement resolution of CAFM is far superior to that of SSPM. With the DVD + RW disc rotating at a linear speed of 3.5 m/s, appropriate writing laser power range, may be precisely identified by CAFM as 10-15 mW. This is sufficient to verify the high-resolution recording bits research method. This new method may also be applied to the development of new types of phase-change recording materials.

Image Processing, Computer-Assisted↗

Image analysis by pulse coupled neural networks (PCNN)--a novel approach in granule size characterization.

A biologically inspired spiking neural network model, the pulse coupled neural network (PCNN), has been applied for the first time in bulk particle characterization, and specifically in the characterization of pharmaceutical granule size distributions. The PCNN was trained on surface images of pharmaceutical granule beds, and the adjustable parameters (radius neuron interconnection, r0, linking weight coefficient, beta, local threshold potential, VTheta, and number of iterations) were successfully optimized using design of experiments. As demonstrated with size fractions of granules, it was found that the PCNN produced granule size-dependent signals. In general, a first highest and relatively narrow peak located in the region of two to twelve iterations corresponded to smaller particle size, while larger particles resulted in wider peaks and in highest (not first) peak at a range between 13 and 25 iterations. Better predictions, i.e. lower RMSEP (root mean squared error of prediction) values, were obtained using high beta value, low r0 and VTheta values, while the number of iterations had to exceed 110 and the optimized model (RMSEP lower than 5) corresponded to PCNN variables: r0=1, beta=0.4, VTheta=2, and number of iterations=150. The coefficient of determination (R2) of the model was 0.94 and the predicted variation (Q2) was 0.91, while the Pearson correlation coefficient between the predicted and the measured mean particle size by sieving for eight test batches was 0.98. These findings could be characterized as promising and encouraging for the further use of image analysis by PCNNs in pharmaceutical bulk particle size and shape characterization.

Image Processing, Computer-Assisted↗

Production of siRNA- and cDNA-transfected cell arrays on noncoated chambered coverglass for high-content screening microscopy in living cells.

In this chapter, we provide a protocol for the production of transfected cell arrays in living mammalian cells on noncoated chambered coverglass for the systematic functional analyses of human genes by high-content screening microscopy. This method should facilitate drug target validation by small-interfering RNAs.

Image Processing, Computer-Assisted↗